Monte Carlo simulation code for confocal 3D micro-beam X-ray fluorescence analysis of stratifiedmaterials

被引:25
|
作者
Czyzycki, Mateusz [1 ]
Wegrzynek, Dariusz [1 ]
Wrobel, Pawel [1 ]
Lankosz, Andmarek [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, PL-30059 Krakow, Poland
关键词
TRACE-ELEMENT ANALYSIS; COMET; 81P/WILD-2; PAINT LAYERS; MU-XRF; MICROFLUORESCENCE; SPECTROSCOPY; PARTICLES; OPTICS;
D O I
10.1002/xrs.1300
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Stratified materials are of great importance for many branches of modern industry, e. g. electronics or optics and for biomedical applications. Examination of chemical composition of individual layers and determination of their thickness helps to get information on their properties and function. A confocal 3D micro X-ray fluorescence (3D mu XRF) spectroscopy is an analytical method giving the possibility to investigate 3D distribution of chemical elements in a sample with spatial resolution in the micrometer regime in a non-destructive way. Thin foils of Ti, Cu and Au, a bulk sample of Cu and a three-layered sandwich sample, made of two thin Fe/Ni alloy foils, separated by polypropylene, were used as test samples. A Monte Carlo (MC) simulation code for the determination of elemental concentrations and thickness of individual layers in stratified materials with the use of confocal 3D mu XRF spectroscopy was developed. The X-ray intensity profiles versus the depth below surface, obtained from 3D mu XRF experiments, MC simulation and an analytical approach were compared. Correlation coefficients between experimental versus simulated, and experimental versus analytical model X-ray profiles were calculated. The correlation coefficients were comparable for both methods and exceeded 99%. The experimental X-ray intensity profiles were deconvoluted with iterative MC simulation and by using analytical expression. The MC method produced slightly more accurate elemental concentrations and thickness of successive layers as compared to the results of the analytical approach. This MC code is a robust tool for simulation of scanning confocal 3D mu XRF experiments on stratified materials and for quantitative interpretation of experimental results. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:88 / 95
页数:8
相关论文
共 50 条
  • [1] Quantitative elemental analysis of individual particles with the use of micro-beam X-ray fluorescence method and Monte Carlo simulation
    Czyzycki, Mateusz
    Bielewski, Marek
    Lankosz, Marek
    X-RAY SPECTROMETRY, 2009, 38 (06) : 487 - 491
  • [2] Application of Confocal Micro-Beam X-Ray Fluorescence in Nondestructive Scanning Analysis of the Distribution of Elements in a Single Hair
    Liu He-he
    Liu Zhi-guo
    Sun Tian-xi
    Peng Song
    Zhao Wei-gang
    Sun Wei-yuan
    Li Yu-de
    Lin Xiao-yan
    Zhao Guang-cui
    Luo Ping
    Ding Xun-liang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (11) : 3153 - 3156
  • [3] A model for the confocal volume of 3D micro X-ray fluorescence spectrometer
    Malzer, W
    Kanngiesser, B
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (9-10) : 1334 - 1341
  • [4] Neutron micro-beam design simulation by Monte Carlo
    Pazirandeh, Ali
    Taheri, Ali
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 384 - 387
  • [5] Micro-beam x-ray fluorescence analysis of individual particles with correction for absorption effects
    Bielewski, M.
    Wegrzynek, D.
    Lankosz, M.
    Markowicz, A.
    Chinea-Cano, E.
    Bamford, S. Akoto
    X-RAY SPECTROMETRY, 2006, 35 (04) : 238 - 242
  • [6] Measurement of coating thickness on wires by micro-beam X-ray fluorescence
    Rößiger, V.
    Galvanotechnik, 2002, 93 (09): : 2262 - 2265
  • [7] Quantification for 3D micro X-ray fluorescence
    Mantouvalou, Ioanna
    Malzer, Wolfgang
    Kanngiesser, Birgit
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 77 : 9 - 18
  • [8] Ion beam irradiation of nanostructures - A 3D Monte Carlo simulation code
    Borschel, C.
    Ronning, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (19): : 2133 - 2138
  • [9] Optimization of in vivo X-ray fluorescence analysis methods for bone lead by simulation with the Monte Carlo code CEARXRF
    Ao, Q
    Lee, SH
    Gardner, RP
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (10-12) : 1413 - 1423
  • [10] Study of the x-ray source with micro-beam
    Wang, KG
    Niu, HB
    BIOMEDICAL PHOTONICS AND OPTOELECTRONIC IMAGING, 2000, 4224 : 101 - 104