Testing a novel biotechnological passive sampler for monitoring atmospheric PAH pollution

被引:17
|
作者
Aboal, J. R. [1 ]
Concha-Grana, E. [2 ]
De Nicola, F. [3 ]
Muniategui-Lorenzo, S. [2 ]
Lopez-Mahia, P. [2 ]
Giordano, S. [4 ]
Capozzi, F. [4 ]
Di Palma, A. [5 ]
Reski, R. [6 ,7 ]
Zechmeister, H. [8 ]
Martinez-Abaigar, J. [9 ]
Fernandez, J. A. [1 ]
机构
[1] Univ Santiago de Compostela, Fac Biol, Dept Biol Func, Area Ecol, Santiago De Compostela 15782, Spain
[2] Univ A Coruna, Grp Quim Analit Aplicada QANAP, IUMA, Fac Ciencias,CICA, La Coruna 15071, Spain
[3] Univ Sannio, Dept Sci & Technol, Via F De Sanctis SNC, I-82100 Benevento, Italy
[4] Univ Naples Federico II, Dept Biol, Campus Monte S Angelo,Via Cinthia 4, I-80126 Naples, Italy
[5] Univ Naples Federico II, Dept Agr Sci, Via Univ 100, I-80055 Portici, NA, Italy
[6] Univ Freiburg, Fac Biol, Plant Biotechnol, Schaenzlestr 1, D-79104 Freiburg, Germany
[7] BIOSS Ctr Biol Signalling Studies, D-79104 Freiburg, Germany
[8] Univ Vienna, Dept Conservat Vegetat & Landscape Biol, Rennweg 14, A-1030 Vienna, Austria
[9] Univ La Rioja, Edificio Cient Tecnol,Avd Madre de Dios 51, Logrono 26006, Spain
关键词
Moss bags; Active monitoring; Polycyclic aromatic hydrocarbons; POLYCYCLIC AROMATIC-HYDROCARBONS; MOSS HYPNUM-CUPRESSIFORME; TERRESTRIAL MOSSES; HEAVY-METALS; DEPOSITION; BULK; BAGS; REPLICABILITY; CONTAMINANTS; PHENANTHRENE;
D O I
10.1016/j.jhazmat.2019.120949
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study we evaluated a new type of passive air sampler, the "mossphere" device, filled with a Sphagnum palustre clone. For this purpose, we compared the atmospheric levels of polyaromatic hydrocarbons (PAHs) collected using this device and those collected in conventional bulk deposition and particulate matter (PM10) samplers. All three types of samplers were exposed at 10 sites affected by different levels of pollution and located in two different climate zones. The bulk deposition/ mossphere comparison yielded a greater number of significant regressions with higher coefficients of determination than the PM10/ mossphere comparison. No significant regressions were observed for 3-ring PAHs in either comparison. The mosspheres explain ca. 50% of the variability of the concentrations of 4-, 5- and 6-ring PAHs and total PAHs detected in PM10 and ca. 70% of the corresponding concentrations detected in the bulk deposition. The use of the Sphagnum clone enables standardization of the set-up, thus making the mossphere device a good sampling tool for monitoring 4-, 5- and 6-ring and total PAHs, especially those associated with bulk deposition. The findings indicate the potential usefulness of this innovative technology for mapping PAH levels.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Novel silica sol-gel passive sampler for mercury monitoring in aqueous systems
    Zhou, Yan
    Stotesbury, Theresa
    Dimock, Brian
    Vreugdenhil, Andrew
    Hintelmann, Holger
    CHEMOSPHERE, 2013, 90 (02) : 323 - 328
  • [22] Some experiences of atmospheric PAH monitoring in France
    Tatry, V
    Dujardin, R
    Person, A
    FRESENIUS ENVIRONMENTAL BULLETIN, 1999, 8 (9-10): : 619 - 628
  • [23] Application of the Passive Sampler Developed for Atmospheric Mercury and Its Limitation
    Jeon, Ji-Won
    Han, Young-Ji
    Cha, Seung-Hwan
    Kim, Pyung-Rae
    Kim, Young-Hee
    Kim, Hyuk
    Seok, Gwang-Seol
    Noh, Seam
    ATMOSPHERE, 2019, 10 (11)
  • [24] Validation of an passive atmospheric deposition sampler for polybrominated diphenyl ethers
    Gocht, Tilman
    Moeckel, Claudia
    Chaemfa, Chakra
    Thomas, Gareth O.
    Jones, Kevin C.
    JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (11): : 1176 - 1182
  • [25] A new passive sampler for collecting atmospheric tritiated water vapor
    Feng, Bin
    Chen, Bo
    Zhuo, Weihai
    Zhang, Weiyuan
    ATMOSPHERIC ENVIRONMENT, 2017, 154 : 308 - 317
  • [26] A PLASTIC-BAG SAMPLER FOR PASSIVE RADON MONITORING
    TOMMASINO, L
    CHEROUATI, DE
    SEIDEL, JL
    MONNIN, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 681 - 684
  • [27] A passive-discrete water sampler for monitoring seepage
    Salve, R
    GROUND WATER, 2005, 43 (01) : 133 - 137
  • [28] A passive sampler for monitoring urban particulate: Preliminary results
    Brown, RC
    Thorpe, A
    Hemingway, MA
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 1998, 52 (1-2) : 19 - 28
  • [29] A Passive Sampler for Monitoring Urban Particulate: Preliminary Results
    R C Brown
    A Thorpe
    M a Hemingway
    Environmental Monitoring and Assessment, 1998, 52 : 19 - 28
  • [30] Validation of cheap axial passive sampler and procedure suitable for atmospheric NO2 community-based monitoring
    Moretta, Alma
    Sofia, Daniele
    Ricciardi, Maria
    Venditto, Vincenzo
    Proto, Antonio
    ATMOSPHERIC POLLUTION RESEARCH, 2024, 15 (09)