摘要
Towers play a vital role in the transmission line (TL) system. The main objective of the present study is to analyse the failure of towers subjected to dust storms. This study, analyses the failure of a 765 kV single-circuit delta-type horizontal configuration tower in the river delta region near Agra. TL towers are designed based on IS 802 Part 1/Sec 1 and 2 standards. Dust particles of soil may be lighter individually, but have definite density. The wind carrying dust particles may increase the wind pressure on the tower line system. The increased wind pressure significantly affects the sag and tension of ground wire and conductor and results in additional loads on the tower, thus causing failure. It also increases wind load on the tower body and insulator string. There is literature related to numerical and wind tunnel studies on the combined effect of wind and rain loads, but no information is available on the wind and dust loads at present. The density variation method is used in the present study for calculation of additional wind pressure due to dust particles during storms. A relation between density of air mix, volume fraction of dust and density of dust particles is considered. Using FEM software, the tower is analysed for existing design loads and verified for its strength adequacy. The tower stability is studied by analysing for additional loads considering the presence of dust particles in the wind for three different volume fractions of 0.01%/m(3), 0.02%/m(3) and 0.03%/m(3). The wind pressure increases by about 10% for an increase of every 0.01% of dust particles in the wind. The tension in the conductor and ground wire increases by 8%. The existing tower design is inadequate to withstand the additional forces from wind storms associated even with a small fraction of dust particles and may be the reason for the failure of towers in northern India during a particular period of the year.
引用
收藏
页码:511 / 520
页数:10
相关论文
共 50 条
  • [41] A Review of Research on Supported Transmission Line Tower Failure Studies: Analysis, Tower Testing and Retrofitting
    Chatterjee, Ayush
    Bosco, Evlin
    Rajagopalan, Srinivas
    Varghese, Isaac M.
    Ramalingam, Raghavan
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2024, 24 (02) : 264 - 279
  • [42] A Review of Research on Supported Transmission Line Tower Failure Studies: Analysis, Tower Testing and Retrofitting
    Ayush Chatterjee
    Evlin Bosco
    Srinivas Rajagopalan
    Isaac M. Varghese
    Raghavan Ramalingam
    International Journal of Steel Structures, 2024, 24 : 264 - 279
  • [43] Collapse failure analysis and fragility analysis of a transmission tower-line system subjected to the multidimensional ground motion of different input directions
    Tian, Li
    Yang, Meng
    Liu, Shiyuan
    Liu, Juncai
    Gao, Guodong
    Yang, Zeying
    STRUCTURES, 2023, 48 : 1018 - 1028
  • [44] Wind fragility assessment and sensitivity analysis for a transmission tower-line system
    Wang, Jia
    Li, Hong-Nan
    Fu, Xing
    Dong, Zhi-Qian
    Sun, Zhi-Guo
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2022, 231
  • [45] UTILIZING FBG FOR STABILITY AND FAILURE MONITORING OF POWER LINE TRANSMISSION TOWERS SUBJECTED TO HURRICANE LOADS
    Zabihollahl, Abolghassem
    Vuddanduml, Rajesh
    Abu-Ghazalehl, Haitham
    Sandoval, Raul
    PROCEEDINGS OF ASME 2024 CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, SMASIS 2024, 2024,
  • [46] Wind tunnel tests on wind loads acting on an angled steel triangular transmission tower
    Yang, Fengli
    Dang, Huixue
    Niu, Huawei
    Zhang, Hongjie
    Zhu, Binrong
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2016, 156 : 93 - 103
  • [47] Field measurements of wind-induced transmission tower foundation loads
    Savory, E.
    Parke, G.A.R.
    Disney, P.
    Toy, N.
    Zeinoddini, M.
    Wind and Structures, An International Journal, 1998, 1 (02): : 183 - 199
  • [48] Dynamic energy of a large scale transmission tower subjected to wind excitations
    Li Bo
    Chen Bo
    Xia Chun
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 3645 - +
  • [49] Nonlinear Dynamic Analysis of Transmission Line Cables under Synoptic Wind Loads
    de Oliveira, Camila Cordeiro
    Carvalho, Hermes
    Verga Mendes, Victor Roberto
    Fonseca de Oliveira Correia, Jose Antonio
    Fazeres-Ferradosa, Tiago
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2020, 25 (04)
  • [50] Reliability of Tower and Tower-Line Systems under Spatiotemporally Varying Wind or Earthquake Loads
    Yang, S. C.
    Liu, T. J.
    Hong, H. P.
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (10)