Ratiometric fluorescence probe for hydrazine vapor detection and biological imaging

被引:56
|
作者
Zhang, Weijie [1 ]
Huo, Fangjun [2 ]
Liu, Tao [1 ]
Yin, Caixia [1 ]
机构
[1] Shanxi Univ, Inst Mol Sci, Key Lab Mat Energy Convers & Storage Shanxi Prov, Minist Educ,Key Lab Chem Biol & Mol Engn, Taiyuan 030006, Shanxi, Peoples R China
[2] Shanxi Univ, Res Inst Appl Chem, Taiyuan 030006, Shanxi, Peoples R China
基金
中国国家自然科学基金; 山西省归国人员基金;
关键词
SELECTIVE DETECTION; CHEMICAL SENSOR; FUEL-CELLS; IN-VIVO; OXIDATION;
D O I
10.1039/c8tb02536c
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Hydrazine (N2H4) has been widely applied in most of the chemical industry; however, it is now believed that it can cause serious damage to protein and nucleic acid upon ingestion. Herein we introduced a specially designed molecular probe 1, with an electron deficient lactone group as a specially designed reactive site and a naphthalimide fluorophore that is easily modified owing to lactone involvement. The free probe 1 exhibited blue fluorescence in neutral buffer owing to the low favorability of ICT (intramolecular charge transfer), while the specially designed lactone group could potentially undergo a ring-opening reaction with hydrazine, resulting in a favoured ICT effect and bathochromically shifted (125 nm) fluorescence response. The ratiometric fluorescence signal enabled quantitative determination of hydrazine using probe 1 in complex applications. Besides, probe 1 features a rapid signal response time (within 5 min) and low detection limit (36 nM) for hydrazine. Utilizing these excellent properties, probe 1 was further applied in hydrazine vapor detection and bio-imaging. Conceptually, we now present a new approach for the detection of hydrazine, and the enhanced performances of probe 1 will promote its applications in living systems and the environment.
引用
收藏
页码:8085 / 8089
页数:5
相关论文
共 50 条
  • [21] A Fluorescence Ratiometric Probe for Imaging of Acidic pH in Living Cells
    Long, Lingliang
    Wu, Yanjun
    Wang, Lin
    ENVIRONMENTAL ENGINEERING, PTS 1-4, 2014, 864-867 : 83 - 87
  • [22] Novel ratiometric fluorescent probe based on internal reference and its detection of hydrazine
    Xiaohong Cheng
    Shuang Li
    Mengyun Gong
    Song Wang
    Wangnan Li
    Journal of Fluorescence, 2022, 32 : 1135 - 1141
  • [23] Novel ratiometric fluorescent probe based on internal reference and its detection of hydrazine
    Cheng, Xiaohong
    Li, Shuang
    Gong, Mengyun
    Wang, Song
    Li, Wangnan
    JOURNAL OF FLUORESCENCE, 2022, 32 (03) : 1135 - 1141
  • [24] A colorimetric and near-infrared ratiometric fluorescent probe for hydrazine detection and bioimaging
    Wu, Cuiyan
    Xie, Ruihua
    Pang, Xiao
    Li, Yaqian
    Zhou, Zile
    Li, Haitao
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 243
  • [25] Fluorescence Ratiometric Sensor for Trace Vapor Detection of Hydrogen Peroxide
    Xu, Miao
    Han, Ji-Min
    Wang, Chen
    Yang, Xiaomei
    Pei, Jian
    Zang, Ling
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (11) : 8708 - 8714
  • [26] ESIPT-based fluorescence probe for the ratiometric detection of superoxide
    Wu, Luling
    Liu, Liyuan
    Han, Hai-Hao
    Tian, Xue
    Odyniec, Maria L.
    Feng, Lei
    Sedgwick, Adam C.
    He, Xiao-Peng
    Bull, Steven D.
    James, Tony D.
    NEW JOURNAL OF CHEMISTRY, 2019, 43 (07) : 2875 - 2877
  • [27] A Novel Double Fluorescence-Suppressed Probe for the Detection of Hydrazine
    Li, Xue
    Yin, Jiwei
    Liu, Weiyan
    Yang, Yutao
    Xu, Wenzhi
    Li, Wei
    CHEMISTRYSELECT, 2019, 4 (48): : 14069 - 14074
  • [28] A sensitive TICT Probe exhibiting ratiometric fluorescence repose to detect hydrazine in solution and gas phase
    Gupta, Ramesh C.
    Dwivedi, Sushil K.
    Ali, Rashid
    Razi, Syed S.
    Tiwari, Rudramani
    Krishnamoorthi, S.
    Misra, Arvind
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 232
  • [29] A probe for ratiometric near-infrared fluorescence and colorimetric hydrogen sulfide detection and imaging in live cells
    Maity, Debabrata
    Raj, Anand
    Samanta, Pralok K.
    Karthigeyan, D.
    Kundu, Tapas K.
    Pati, Swapan K.
    Govindaraju, T.
    RSC ADVANCES, 2014, 4 (22): : 11147 - 11151
  • [30] Ratiometric detection and imaging of endogenous alkaline phosphatase activity by fluorescein-coumarin-based fluorescence probe
    Cao, Jingrui
    Wu, Qiong
    Chang, Xin
    Chu, Hongyu
    Zhang, Hong
    Fang, Xuedong
    Chen, Fangfang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 281