Fatigue and Fluoride Corrosion on Streptococcus mutans Adherence to Titanium-Based Implant/Component Surfaces

被引:38
|
作者
Correa, Cassia Bellotto [1 ]
Pires, Juliana Rico [2 ]
Fernandes-Filho, Romeu Belon [2 ]
Sartori, Rafael [2 ]
Vaz, Luis Geraldo [1 ]
机构
[1] Sao Paulo State Univ, Dept Dent Mat & Prosthodont, UNESP, BR-14800000 Araraquara, SP, Brazil
[2] Sao Paulo State Univ, Dept Periodontol, UNESP, BR-14800000 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Fluoride; corrosion; dental implants; bacterial adhesion;
D O I
10.1111/j.1532-849X.2009.00463.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The influence of fatigue and the fluoride ion corrosion process on Streptococcus mutans adherence to commercially pure Titanium (Cp Ti) implant/component set surfaces were studied. Materials and Methods: Thirty Nobel implants and 30 Neodent implants were used. Each commercial brand was divided into three groups. Group A: control, Group B: sets submitted to fatigue (105 cycles, 15 Hz, 150 N), and Group C: sets submitted to fluoride (1500 ppm, pH 5.5) and fatigue, simulating a mean use of 5 years in the oral medium. Afterward, the sets were contaminated with standard strains of S. mutans (NTCC 1023) and analyzed by scanning electronic microscopy (SEM) and colony-forming unit counts (CFU/mL). Results: By SEM, bacterial adherence was verified only in group C in both brands. By CFU/mL counts, S. mutans was statistically higher in both brands in group C than in groups A and B (p < 0.05, ANOVA). Conclusion: The process of corrosion by fluoride ions on Cp Ti implant/component sets allowed greater S. mutans adherence than in the absence of corrosion and with the fatigue process in isolation.
引用
收藏
页码:382 / 387
页数:6
相关论文
共 50 条
  • [21] Influence of micro-textures on antibacterial behaviour of titanium-based implant surfaces: In vitro studies
    Vadakkumpurath S.
    Venugopal A.N.
    Ullattil S.
    Biosurface and Biotribology, 2019, 5 (01): : 20 - 23
  • [22] Antibiofilm peptides enhance the corrosion resistance of titanium in the presence of Streptococcus mutans
    Wang, Dan
    Yue, Yingying
    Liu, He
    Zhang, Tian
    Haney, Evan F.
    Hancock, Robert E. W.
    Yu, Jian
    Shen, Ya
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 11
  • [23] Corrosion, fatigue and corrosion fatigue behaviour of metal implant materials, especially titanium alloys
    Fleck, Claudia
    Eifler, Dietmar
    INTERNATIONAL JOURNAL OF FATIGUE, 2010, 32 (06) : 929 - 935
  • [24] CORROSION PERFORMANCE OF SOME TITANIUM-BASED HARD COATINGS
    MATTHES, B
    BROSZEIT, E
    AROMAA, J
    RONKAINEN, H
    HANNULA, SP
    LEYLAND, A
    MATTHEWS, A
    SURFACE & COATINGS TECHNOLOGY, 1991, 49 (1-3): : 489 - 495
  • [25] Removal of fluoride from water using titanium-based adsorbents
    Zhijian Li
    Shubo Deng
    Xueying Zhang
    Wei Zhou
    Jun Huang
    Gang Yu
    Frontiers of Environmental Science & Engineering in China, 2010, 4 : 414 - 420
  • [26] Removal of fluoride from water using titanium-based adsorbents
    Li, Zhijian
    Deng, Shubo
    Zhang, Xueying
    Zhou, Wei
    Huang, Jun
    Yu, Gang
    FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING IN CHINA, 2010, 4 (04): : 414 - 420
  • [27] Engineering Antioxidant Surfaces for Titanium-Based Metallic Biomaterials
    Vishnu, Jithin
    Kesavan, Praveenkumar
    Shankar, Balakrishnan
    Dembinska, Katarzyna
    Brzezinska, Maria Swiontek
    Kaczmarek-Szczepanska, Beata
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (07)
  • [28] Surface studies of titanium-based dental implant materials.
    Placko, HE
    Perry, W
    Mishra, S
    Lucas, LC
    Weimer, JJ
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1514 - 1514
  • [29] FURTHER-STUDIES OF AN ADHERENCE-BLOCKING COMPONENT FROM STREPTOCOCCUS-MUTANS
    PEROS, WJ
    GIBBONS, RJ
    JOURNAL OF DENTAL RESEARCH, 1984, 63 : 321 - 321
  • [30] NEW GLUCAN SYNTHESIS AS A PREREQUISITE FOR ADHERENCE OF STREPTOCOCCUS-MUTANS TO SMOOTH GLASS SURFACES
    HAMADA, S
    MICROBIOS LETTERS, 1977, 5 (19-2): : 141 - 146