Fatigue and Fluoride Corrosion on Streptococcus mutans Adherence to Titanium-Based Implant/Component Surfaces

被引:38
|
作者
Correa, Cassia Bellotto [1 ]
Pires, Juliana Rico [2 ]
Fernandes-Filho, Romeu Belon [2 ]
Sartori, Rafael [2 ]
Vaz, Luis Geraldo [1 ]
机构
[1] Sao Paulo State Univ, Dept Dent Mat & Prosthodont, UNESP, BR-14800000 Araraquara, SP, Brazil
[2] Sao Paulo State Univ, Dept Periodontol, UNESP, BR-14800000 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Fluoride; corrosion; dental implants; bacterial adhesion;
D O I
10.1111/j.1532-849X.2009.00463.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The influence of fatigue and the fluoride ion corrosion process on Streptococcus mutans adherence to commercially pure Titanium (Cp Ti) implant/component set surfaces were studied. Materials and Methods: Thirty Nobel implants and 30 Neodent implants were used. Each commercial brand was divided into three groups. Group A: control, Group B: sets submitted to fatigue (105 cycles, 15 Hz, 150 N), and Group C: sets submitted to fluoride (1500 ppm, pH 5.5) and fatigue, simulating a mean use of 5 years in the oral medium. Afterward, the sets were contaminated with standard strains of S. mutans (NTCC 1023) and analyzed by scanning electronic microscopy (SEM) and colony-forming unit counts (CFU/mL). Results: By SEM, bacterial adherence was verified only in group C in both brands. By CFU/mL counts, S. mutans was statistically higher in both brands in group C than in groups A and B (p < 0.05, ANOVA). Conclusion: The process of corrosion by fluoride ions on Cp Ti implant/component sets allowed greater S. mutans adherence than in the absence of corrosion and with the fatigue process in isolation.
引用
收藏
页码:382 / 387
页数:6
相关论文
共 50 条
  • [1] Galvanic corrosion of titanium-based dental implant materials
    Arslan, Halit
    Celikkan, Hueseyin
    Oernek, Nisa
    Ozan, Oguz
    Ersoy, A. Ersan
    Aksu, M. Levent
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2008, 38 (06) : 853 - 859
  • [2] Galvanic corrosion of titanium-based dental implant materials
    Halit Arslan
    Hüseyin Çelikkan
    Nisa Örnek
    Oğuz Ozan
    A. Ersan Ersoy
    M. Levent Aksu
    Journal of Applied Electrochemistry, 2008, 38 : 853 - 859
  • [3] ADHERENCE OF STREPTOCOCCUS-MUTANS TO IMPLANT MATERIALS
    FUJIOKAHIRAI, Y
    AKAGAWA, Y
    MINAGI, S
    TSURU, H
    MIYAKE, Y
    SUGINAKA, H
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (07): : 913 - 920
  • [4] FLUORIDE RESISTANCE AND ADHERENCE OF SELECTED STRAINS OF STREPTOCOCCUS-MUTANS TO SMOOTH SURFACES AFTER EXPOSURE TO FLUORIDE
    STRECKFUSS, JL
    PERKINS, D
    HORTON, IM
    BROWN, LR
    DREIZEN, S
    GRAVES, L
    JOURNAL OF DENTAL RESEARCH, 1980, 59 (02) : 151 - 158
  • [5] Corrosion behaviour of titanium in the presence of Streptococcus mutans
    Souza, Julio C. M.
    Ponthiaux, Pierre
    Henriques, Mariana
    Oliveira, Rosario
    Teughels, Wim
    Celis, Jean-Pierre
    Rocha, Luis A.
    JOURNAL OF DENTISTRY, 2013, 41 (06) : 528 - 534
  • [6] Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials
    Aziz-Kerrzo, M
    Conroy, KG
    Fenelon, AM
    Farrell, ST
    Breslin, CB
    BIOMATERIALS, 2001, 22 (12) : 1531 - 1539
  • [7] INHIBITION OF ADHERENCE OF STREPTOCOCCUS-MUTANS TO GLASS SURFACES
    NEWBRUN, E
    FINZEN, F
    SHARMA, M
    CARIES RESEARCH, 1977, 11 (03) : 153 - 159
  • [8] In vitro adherence of Streptococcus mutans to root surfaces.
    Sordelli, AE
    Gregory, RL
    González-Cabezas, C
    Fontana, M
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 226 - 226
  • [9] Electrochemical corrosion of titanium and titanium-based alloys
    Kuphasuk, C
    Oshida, Y
    Andres, CJ
    Hovijitra, ST
    Barco, MT
    Brown, DT
    JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (02): : 195 - 202
  • [10] EXTRACTION OF AN ADHERENCE BLOCKING COMPONENT FROM STREPTOCOCCUS-MUTANS
    PEROS, WJ
    GIBBONS, RJ
    JOURNAL OF DENTAL RESEARCH, 1983, 62 : 257 - 257