Retractable Loop-Gap Resonators for Electron Paramagnetic Resonance Imaging with In Situ Irradiation Capabilities

被引:5
|
作者
Epel, Boris [1 ]
Sundramoorthy, Subramanian V. [1 ]
Halpern, Howard J. [1 ]
机构
[1] Univ Chicago, Dept Radiat & Cellular Oncol, Ctr EPR Imaging Vivo Physiol, Chicago, IL 60637 USA
关键词
EPR; EPR imaging; in vivo imaging; resonator;
D O I
10.1002/cmr.b.20205
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A retractable split-top loop-gap resonator for both continuous wave and pulse electron paramagnetic resonance imaging of small animals with open, clam shell style design to allow convenient access to the sample for in situ animal irradiation is described. The resonator can be either rigidly attached to the animal support bed or floated independently from the bed to avoid communication of the mechanical vibrations of the bed to the resonator. Multiple split-top resonators for different animal sizes were built and tested. The characteristics of split-top resonators are comparable with those of loop-gap resonators used previously. The imaging experiments that involved the sham animal irradiation between pairs of images demonstrated very good maintenance of animal position between images. (C) 2011 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 39B: 167-172, 2011
引用
收藏
页码:167 / 172
页数:6
相关论文
共 50 条
  • [21] THE LOOP-GAP RESONATOR - A NEW MICROWAVE LUMPED CIRCUIT ELECTRON-SPIN-RESONANCE SAMPLE STRUCTURE
    FRONCISZ, W
    HYDE, JS
    JOURNAL OF MAGNETIC RESONANCE, 1982, 47 (03) : 515 - 521
  • [22] Microstrip resonators for electron paramagnetic resonance experiments
    Torrezan, A. C.
    Alegre, T. P. Mayer
    Medeiros-Ribeiro, G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (07):
  • [23] Resonance frequency estimation of a bridged loop-gap resonator used for magnetic resonance measurements
    Hirata, H
    Ono, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (01): : 73 - 78
  • [24] OPTIMUM DESIGN AND PERFORMANCE OF A 1.4 GHZ LOOP-GAP RESONATOR USED IN AN ELECTRON-SPIN-RESONANCE SPECTROMETER
    CHEN, KY
    LIU, W
    FENG, YH
    LI, WX
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (07): : 660 - 662
  • [25] BRIDGED LOOP-GAP AND DIELECTRIC RESONATORS FOR PULSED ESR AND ENDOR SPECTROSCOPY WITH LIGHT EXCITATION
    FORRER, J
    PFENNINGER, S
    SCHWEIGER, A
    WEILAND, T
    MAGNETIC RESONANCE AND RELATED PHENOMENA, 1989, : 919 - 924
  • [26] Optimization of axial RF field distribution in low-frequency EPR loop-gap resonators
    Diodato, R
    Alecci, M
    Brivati, JA
    Varoli, V
    Sotgiu, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (05): : N69 - N75
  • [27] Cavity- and waveguide-resonators in electron paramagnetic resonance, nuclear magnetic resonance, and magnetic resonance imaging
    Webb, Andrew
    PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 2014, 83 : 1 - 20
  • [28] Evaluation of sub-microsecond recovery resonators for in vivo electron paramagnetic resonance imaging
    Hyodo, F.
    Subramanian, S.
    Devasahayam, N.
    Murugesan, R.
    Matsumoto, K.
    Mitchell, J. B.
    Krishna, M. C.
    JOURNAL OF MAGNETIC RESONANCE, 2008, 190 (02) : 248 - 254
  • [29] SATURATION TRANSFER ELECTRON-PARAMAGNETIC-RES SPECTROSCOPY ON SPIN-LABELED MUSCLE-FIBERS USING A LOOP-GAP RESONATOR
    THOMAS, DD
    WENDT, CH
    FRONCISZ, W
    HYDE, JS
    BIOPHYSICAL JOURNAL, 1983, 43 (01) : 131 - 135
  • [30] AN EXAMPLE OF INVIVO ANALYSIS BY L-BAND ELECTRON-SPIN-RESONANCE TECHNIQUE USING A LOOP-GAP RESONATOR
    OGATA, T
    ONO, M
    FUJISAWA, T
    YOSHIDA, E
    KAMADA, H