A new rebinning algorithm for 3D PET data

被引:1
|
作者
Erlandsson, Kjell [1 ]
van Heertum, Ronald [1 ]
Mann, J. John [1 ]
机构
[1] Columbia Univ, Dept Psychiat, New York, NY USA
关键词
D O I
10.1109/NSSMIC.2006.353720
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
3D acquisition mode in PET is a way to increase the sensitivity of the scanner. To reconstruct the 3D data it is necessary to use either a fully 3D reconstruction algorithm or, alternatively, a rebinning algorithm followed by 2D reconstruction. The advantages of the 2(nd) approach are higher speed and reduced data size. Rebinning algorithms may become more important in the future with time-of-flight PET due to the increased dimensionality of the projection data. Although two exact rebinning algorithms have been developed, the most commonly used method today is the approximate Fourier rebinning algorithm. These three methods are based on analytic solutions in the frequency domain and involve geometric approximations, which may be significant for some scanner geometries. They also require attenuation corrected data, which can lead to complications since some reconstruction algorithms work better with non-attenuation corrected data. We have developed a novel rebinning algorithm, called reprojection rebinning (RP-RB), which is free from theoretical and geometric approximations as well as from the requirement of attenuation correction. It is based on an initial reconstruction of a 2D data-subset, which results in a somewhat sub-optimal utilization of the oblique data. The results can be improved, however, by an iterative procedure. We have tested RP-RB using simulated phantom data, showing an SD reduction in the central transaxial plane after the 1(st), 2(nd) and 3(rd) iteration by a factor of 3.0, 3.5 and 4.1, respectively, as compared to 2D data only. There was also a very good spatial accuracy in images reconstructed from noiseless data, even for scanner geometries with large acceptance angles.
引用
收藏
页码:3346 / 3350
页数:5
相关论文
共 50 条
  • [1] Gap filling and rebinning algorithms for 3D PET data
    Hayashi, S.
    Inaji, M.
    Nariai, T.
    Wagatsuma, K.
    Sakata, M.
    Ishii, K.
    Maehara, T.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 : 594 - 594
  • [2] Exact rebinning methods for 3D PET
    Xuan, Liu
    Defrise, Michel
    Michel, Christian
    Sibomana, Merence
    Comtat, Claude
    Kinahan, Paul
    Townsend, David
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 3 : 1604 - 1609
  • [3] A Fourier rebinning algorithm incorporating spectral transfer efficiency for 3D PET
    Tanaka, E
    Amo, Y
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 739 - 746
  • [4] Fourier rebinning for 3D transmission scans in PET
    Becher, AJ
    Karp, JS
    Matej, S
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 178P - 178P
  • [5] An exact Fourier rebinning algorithm for 3D PET imaging using panel detectors
    Kao, CM
    Pan, XC
    Chen, CT
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11): : 2407 - 2423
  • [6] A new weighted multi-slice rebinning algorithm using orthogonal projection in 3D PET.
    Hsu, C
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 214P - 214P
  • [7] A Novel Method for Rebinning in 3D PET Reconstruction on XTRIM PET
    Ghorbanzadeh, M.
    Zare, T.
    Farahani, M. H.
    Tabrizi, S. Hariri
    Alikhani, A. H.
    Fard, B. Teimourian
    Ay, M. R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S758 - S758
  • [8] Rebinning and reconstruction techniques for 3D TOF-PET
    Vandenberghe, Stefaan
    Karp, Joel
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 421 - 424
  • [9] A fast 3D reconstruction algorithm for inverse-geometry CT based on an exact PET rebinning algorithm
    Mazin, Samuel R.
    Pelc, Norbert J.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [10] Data rebinning and reconstruction in 3D PET/CT oncological studies: a Monte Carlo evaluation
    Rizzo, G
    Castiglioni, I
    Russo, G
    Gilardi, MC
    Panzacchi, A
    Fazio, F
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3109 - 3112