Evaluation of a fluorocarbon bonded silica using packed capillary column supercritical fluid chromatography

被引:0
|
作者
Li, WB [1 ]
Ibanez, E [1 ]
Malik, A [1 ]
Lee, ML [1 ]
机构
[1] BRIGHAM YOUNG UNIV,DEPT CHEM,PROVO,UT 84602
关键词
supercritical fluid chromatography; packed capillary columns; perfluorinated polymers; fluorocarbon bonded stationary phase; water modifier; PERFORMANCE LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; STATIONARY PHASES; RETENTION; SEPARATION;
D O I
10.1002/(SICI)1520-667X(1996)8:3<175::AID-MCS2>3.0.CO;2-Z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A newly commercialized fluorinated silica, Fluofix 120N [1H,1H,2H,2H,3H,3H-tridecafluoro(4,4-dimethylheptyl)silyl bonded spherical microporous silica gel], was used as a packing material for supercritical fluid chromatography (SFC). The performance and stability of this fluorinated phase were examined under different experimental conditions. The SFC behavior of this phase was compared with a conventional C-18 bonded reversed phase. The excellent separation power of the Fluofix 120N phase for fluorinated compounds was demonstrated by high-resolution separations of different perfluorinated polymers. (C) 1996 John Wiley & Sons, Inc.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 50 条
  • [31] Modifier effects on column efficiency in packed column supercritical fluid chromatography
    Zou, W
    Dorsey, JG
    Chester, TL
    ANALYTICAL CHEMISTRY, 2000, 72 (15) : 3620 - 3626
  • [32] PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY USING DEACTIVATED STATIONARY PHASES
    ASHRAFKHORASSANI, M
    TAYLOR, LT
    HENRY, RA
    ANALYTICAL CHEMISTRY, 1988, 60 (15) : 1529 - 1533
  • [33] Separation and estimation of seven vasodilators using packed column supercritical fluid chromatography
    Bhoir, IC
    Raman, B
    Sundaresan, M
    Bhagwat, AM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (03) : 539 - 546
  • [34] EVALUATION AND APPLICATION OF A SUPERCRITICAL FLUID EXTRACTION SYSTEM USING CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY
    TAGUCHI, M
    HOBO, T
    MAEDA, T
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1991, 14 (02): : 140 - 143
  • [35] SIMPLE RESTRICTORS FOR CAPILLARY COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY
    GREEN, S
    BERTSCH, W
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (05): : 414 - 415
  • [36] Microelectrochemical detection in capillary column supercritical fluid chromatography
    Wallenborg, SR
    Markides, KE
    Nyholm, L
    PROCEEDINGS OF THE SYMPOSIUM ON CHEMICAL AND BIOLOGICAL SENSORS AND ANALYTICAL ELECTROCHEMICAL METHODS, 1997, 97 (19): : 665 - 673
  • [37] MULTIDIMENSIONAL PACKED CAPILLARY COUPLED TO OPEN TUBULAR COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY USING A VALVE-SWITCHING INTERFACE
    JUVANCZ, Z
    PAYNE, KM
    MARKIDES, KE
    LEE, ML
    ANALYTICAL CHEMISTRY, 1990, 62 (14) : 1384 - 1388
  • [38] A study of polyethoxylated alkylphenols by packed column supercritical fluid chromatography
    Hoffman, BJ
    Taylor, LT
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (02) : 61 - 68
  • [39] Packed column supercritical fluid chromatography of isomeric polypeptide pairs
    Patel, M. A.
    Riley, F.
    Wang, J.
    Lovdahl, M.
    Taylor, L. T.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (18) : 2593 - 2597
  • [40] Separation of drugs by packed-column supercritical fluid chromatography
    Yaku, K
    Morishita, F
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2000, 43 (1-3): : 59 - 76