A feasibility study on an automated method to generate patient-specific dose distributions for radiotherapy using deep learning

被引:148
|
作者
Chen, Xinyuan [1 ,2 ]
Men, Kuo [1 ,2 ]
Li, Yexiong [1 ,2 ]
Yi, Junlin [1 ,2 ]
Dai, Jianrong [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Canc Hosp, Natl Clin Res Ctr Canc, Natl Canc Ctr, Beijing 100021, Peoples R China
[2] Peking Union Med Coll, Beijing 100021, Peoples R China
基金
中国国家自然科学基金;
关键词
automatic; deep learning; dose prediction; radiotherapy; treatment planning; CONVOLUTIONAL NEURAL-NETWORK; QUALITY EVALUATION TOOL; AT-RISK; IMRT; PROSTATE; CANCER; VALIDATION; PREDICTION; ALGORITHM; ASSURANCE;
D O I
10.1002/mp.13262
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop a method for predicting optimal dose distributions, given the planning image and segmented anatomy, by applying deep learning techniques to a database of previously optimized and approved Intensity-modulated radiation therapy treatment plans. Methods Eighty cases of early-stage nasopharyngeal cancer (NPC) were included in the study. Seventy cases were chosen randomly as the training set and the remaining as the test set. The inputs were the images with structures, with each target and organs at risk (OARs) assigned a unique label. The outputs were dose maps, including coarse dose maps and converted fine dose maps (FDM) from convolution. Two types of input images with structures were used in the model building. One type of input included the images (with associated structures) without manipulation. The second type of input involved modifying the image gray label with information from radiation beam geometry. ResNet101 was chosen as the deep learning network for both. The accuracy of predicted dose distributions was evaluated against the corresponding dose as used in the clinic. A global three-dimensional gamma analysis was calculated for the evaluation. Results The proposed model trained with the two different sets of input images and structures could both predict patient-specific dose distributions accurately. For the out-of-field dose distributions, the model obtained from the input with radiation geometry performed better (dose difference in %, 4.7 +/- 6.1% vs 5.5 +/- 7.9%, P < 0.05). The mean Gamma pass rates of dose distributions predicted with both types of input were comparable for most OARs (P > 0.05), except for the bilateral optic nerves and the optic chiasm. Conclusions The proposed system with radiation geometry added to the input is a promising method to generate patient-specific dose distributions for radiotherapy. It can be applied to obtain the dose distributions slice-by-slice for planning quality assurance and for guiding automated planning.
引用
收藏
页码:56 / 64
页数:9
相关论文
共 50 条
  • [41] Automated Patient-specific Quality Assurance for Automated Segmentation of Organs at Risk in Nasopharyngeal Carcinoma Radiotherapy
    Wang, Yixuan
    Hu, Jiang
    Chen, Lixin
    Zhang, Dandan
    Zhu, Jinhan
    CANCER CONTROL, 2025, 32
  • [42] Feasibility of a Patient-Specific Bolus Using the Life-Casting Method for Radiation Therapy
    Kim, Jeongho
    Park, Jeehoon
    Park, Beomjun
    Park, Byungdo
    Kim, Tae-Gyu
    APPLIED SCIENCES-BASEL, 2023, 13 (17):
  • [43] A deep-learning method using single phantom to enhance megavoltage image quality for patient positioning in chest radiotherapy: a feasibility study
    Jeon, Hosang
    Kim, Dong Woon
    Joo, Ji Hyeon
    Ki, Yongkan
    Kim, Wontaek
    Park, Dahl
    Nam, Jiho
    Kim, Dong Hyeon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2023, 83 (01) : 72 - 80
  • [44] A deep-learning method using single phantom to enhance megavoltage image quality for patient positioning in chest radiotherapy: a feasibility study
    Hosang Jeon
    Dong Woon Kim
    Ji Hyeon Joo
    Yongkan Ki
    Wontaek Kim
    Dahl Park
    Jiho Nam
    Dong Hyeon Kim
    Journal of the Korean Physical Society, 2023, 83 : 72 - 80
  • [45] A method to determine the planar dose distributions in patient undergone radiotherapy
    Cilla, S.
    Viola, P.
    Augelli, B. G.
    D'Onofrio, G.
    Grimaldi, L.
    Craus, M.
    Digesu, C.
    Deodato, F.
    Macchia, G.
    Morganti, A. G.
    Fidanzio, A.
    Azario, L.
    Piermattei, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (11): : 2643 - 2650
  • [46] Patient-Specific Sedation Management via Deep Reinforcement Learning
    Eghbali, Niloufar
    Alhanai, Tuka
    Ghassemi, Mohammad M.
    FRONTIERS IN DIGITAL HEALTH, 2021, 3
  • [47] A new method to generate a patient-specific finite element model of the human buttocks
    Wagnac, Eric L.
    Aubin, Carl-Eric
    Dansereau, Jean
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (02) : 774 - 783
  • [48] Evaluation of Delivered Dose Distributions and Metrics: A New Patient-specific QA Protocol
    Klaers, J.
    Saito, A.
    Goddu, S. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S810 - S811
  • [49] An accurate, fast and robust method to generate patient-specific cubic Hermite meshes
    Lamata, Pablo
    Niederer, Steven
    Nordsletten, David
    Barber, David C.
    Roy, Ishani
    Hose, D. Rod
    Smith, Nic
    MEDICAL IMAGE ANALYSIS, 2011, 15 (06) : 801 - 813
  • [50] Feasibility Study of Improving Dose Grid Size Using a Deep Learning
    Shin, D.
    Kim, K.
    Kim, D.
    Kim, T.
    Suh, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E615 - E615