A scheme design of collimator for gantry in proton therapy facility

被引:4
|
作者
Liu, Ming [1 ]
Yin, Chongxian [1 ]
Chu, Kecheng [1 ]
Zhao, Liying [1 ]
Shu, Hang [1 ]
Dai, Xiaolei [1 ]
Zhang, Manzhou [1 ]
Miao, Chunhui [1 ,2 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
Proton therapy; Active scanning; Collimator; Monte Carlo method; ION-THERAPY; BEAMS;
D O I
10.1016/j.nima.2015.04.045
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In proton radiotherapy, a round dose profile at the isocenter is beneficial to the treatment planning in the active scanning mode. Based on the theory of the round-beam method, a collimator was designed to be placed at the entrance of the gantry. A simulation of Monte Carlo method was done to validate the design scheme. With the constraining function of the collimator, the dose profile at the isocenter would maintain a round shape despite of an initial asymmetric phase space in extraction of synchrotron. Furthermore, the shape of dose profile is irrelevant to the rotating angle of the gantry. The mechanical error caused by the axis deviation of the gantry could also be partly eliminated with the collimator. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 50 条
  • [21] Design and development of an ACCT for the Shanghai advanced proton therapy facility
    Zhang, Hong
    Li, Jun-Zhou
    Hou, Rui
    An, Sun
    Xu, Shi-Quan
    Liu, You-Chun
    Zhang, Peng-Jiao
    Song, Jie
    Zhang, Yue-Lin
    NUCLEAR SCIENCE AND TECHNIQUES, 2022, 33 (10)
  • [22] Design and development of an ACCT for the Shanghai advanced proton therapy facility
    Hong Zhang
    Jun-Zhou Li
    Rui Hou
    Sun An
    Shi-Quan Xu
    You-Chun Liu
    Peng-Jiao Zhang
    Jie Song
    Yue-Lin Zhang
    Nuclear Science and Techniques, 2022, 33
  • [23] Design and development of an ACCT for the Shanghai advanced proton therapy facility
    Hong Zhang
    Jun-Zhou Li
    Rui Hou
    Sun An
    Shi-Quan Xu
    You-Chun Liu
    Peng-Jiao Zhang
    Jie Song Yue-Lin Zhang
    NuclearScienceandTechniques, 2022, 33 (10) : 43 - 54
  • [24] Activation induced by proton interactions in a multileaf collimator in proton therapy
    Baldytchev, M
    Bloch, P
    Maughan, R
    McDonough, J
    MEDICAL PHYSICS, 2005, 32 (06) : 2027 - 2027
  • [25] Effect of Gantry and Collimator Positional Errors On Volumetric Modulated Arc Therapy(VMAT)
    Holla, R.
    Ravikumar, V. Anand
    Pillai, B.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [26] Design of a focused collimator for proton therapy spot scanning using Monte Carlo methods
    Geoghegan, Theodore J.
    Nelson, Nicholas P.
    Flynn, Ryan T.
    Hill, Patrick M.
    Rana, Suresh
    Hyer, Daniel E.
    MEDICAL PHYSICS, 2020, 47 (07) : 2725 - 2734
  • [27] Design considerations for a computer controlled multileaf collimator for the Harper Hospital fast neutron therapy facility
    Maughan, RL
    Yudelev, M
    Aref, A
    Chuba, PJ
    Forman, JD
    Blosser, EJ
    Horste, T
    MEDICAL PHYSICS, 2002, 29 (04) : 499 - 508
  • [28] A novel gantry for proton therapy at the Paul Scherrer Institute
    Pedroni, E
    Böhringer, T
    Coray, A
    Goitein, G
    Grossmann, M
    Lomax, A
    Lin, S
    Jermann, M
    CYCLOTRONS AND THEIR APPLICATIONS 2001, 2001, 600 : 13 - 17
  • [29] Design of a large momentum acceptance proton therapy gantry utilizing AG-CCT magnets
    Yi-Cheng Liao
    Xu Liu
    Wei Wang
    Zi-Yi Yang
    Qu-Shan Chen
    Bin Qin
    Nuclear Science and Techniques, 2024, 35 (10) : 94 - 104
  • [30] More than 10 years experience of beam monitoring with the Gantry 1 spot scanning proton therapy facility at PSI
    Lin, Shixiong
    Boehringer, Terence
    Coray, Adolf
    Grossmann, Martin
    Pedroni, Eros
    MEDICAL PHYSICS, 2009, 36 (11) : 5331 - 5340