A scheme design of collimator for gantry in proton therapy facility

被引:4
|
作者
Liu, Ming [1 ]
Yin, Chongxian [1 ]
Chu, Kecheng [1 ]
Zhao, Liying [1 ]
Shu, Hang [1 ]
Dai, Xiaolei [1 ]
Zhang, Manzhou [1 ]
Miao, Chunhui [1 ,2 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
Proton therapy; Active scanning; Collimator; Monte Carlo method; ION-THERAPY; BEAMS;
D O I
10.1016/j.nima.2015.04.045
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In proton radiotherapy, a round dose profile at the isocenter is beneficial to the treatment planning in the active scanning mode. Based on the theory of the round-beam method, a collimator was designed to be placed at the entrance of the gantry. A simulation of Monte Carlo method was done to validate the design scheme. With the constraining function of the collimator, the dose profile at the isocenter would maintain a round shape despite of an initial asymmetric phase space in extraction of synchrotron. Furthermore, the shape of dose profile is irrelevant to the rotating angle of the gantry. The mechanical error caused by the axis deviation of the gantry could also be partly eliminated with the collimator. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 50 条
  • [1] Physical design of scanning gantry for proton therapy facility
    Jiao Yi
    Guan Xia-Ling
    Satogata Todd
    Fang Shou-Xian
    Wei Jie
    Tang Jing-Yu
    Chen Yuan
    Qiu Jing
    Shu Hang
    CHINESE PHYSICS C, 2010, 34 (03) : 394 - 397
  • [2] Physical design of scanning gantry for proton therapy facility
    焦毅
    关遐令
    SATOGATA Todd
    方守贤
    韦杰
    唐靖宇
    陈沅
    邱静
    舒航
    中国物理C, 2010, 34 (03) : 394 - 397
  • [3] Design of Gantry Beamline for HUST Proton Therapy Facility
    Qin, Bin
    Chen, Wei
    Liu, Xu
    Liu, Kaifeng
    Yang, Jun
    Liang, Zhikai
    Chen, Qushan
    Fang, XiaoYu
    Zhao, Zefeng
    Tan, Ping
    Fan, Kuanjun
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (03)
  • [4] Gantry optimization of the Shanghai Advanced Proton Therapy facility
    Wu Jun
    Du Han-Wen
    Xue Song
    Pan Jia-Zhen
    Du Yue-Fei
    Long Ya-Wen
    NUCLEAR SCIENCE AND TECHNIQUES, 2015, 26 (04)
  • [5] Gantry optimization of the Shanghai Advanced Proton Therapy facility
    吴军
    杜涵文
    薛松
    潘家珍
    杜月斐
    龙亚文
    Nuclear Science and Techniques, 2015, 26 (04) : 19 - 23
  • [6] Carbon/proton therapy: A novel gantry design
    Trbojevic, D.
    Parker, B.
    Keil, E.
    Sessler, A. M.
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2007, 10 (05):
  • [7] Maze design of a gantry room for proton therapy
    Agosteo, S
    Birattari, C
    Corrado, MG
    Silari, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 382 (03): : 573 - 582
  • [8] Design of an Achromatic Superconducting Magnet for a Proton Therapy Gantry
    Brouwer, L.
    Caspi, S.
    Hafalia, R.
    Hodgkinson, A.
    Prestemon, S.
    Robin, D.
    Wan, W.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [9] BEAM OPTICS DESIGN OF COMPACT GANTRY FOR PROTON THERAPY
    PEDRONI, E
    ENGE, H
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (03) : 271 - 277
  • [10] Design of cone-beam CT for proton therapy gantry
    Brousmiche, S.
    Seabra, J.
    Labarbe, R.
    Oliva, M. Vila
    Rit, S.
    Wikler, D.
    Lee, J.
    Teo, K.
    de Xivry, J. Orban
    Macq, B.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S52 - S53