α-Si:H/CsI(Tl) flat-panel versus computed radiography for chest imaging applications:: image quality metrics measurement

被引:30
|
作者
Liu, XM [1 ]
Shaw, CC [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
alpha-Si : H/CsI(Tl) flat-panel detector; computed radiography; digital radiography; modulation transfer function; noise power spectra; noise equivalent quanta; detective quantum efficiency;
D O I
10.1118/1.1625102
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Amorphous silicon (a-Si:H) flat-panel (FP) imaging systems have recently become commercially available for both chest and mammographic imaging applications. It has been shown that this new detector technology offers better image quality and various operational advantages over the computed radiography (CR) which to date has been the most widely implemented and used digital radiography technique. However, most image quality measurements reported on flat-panel systems have been performed on prototype systems in laboratories while those for CR systems were typically independently performed and reported on in separate studies. To directly compare the two technologies, we have measured the image properties for a commercial amorphous silicon/cesium iodide [a-Si:H/Csl(T1)] flat-panel based digital chest system and a commercial CR system under clinical imaging conditions. In this paper, measurements of image quality metrics, including the modulation transfer functions (MTFs), noise power spectra (NPSs), and detective quantum efficiencies (DQEs), for the FP and CR systems are presented and compared. Methods and issues related to these measurements are discussed. The results show that the flat-panel system has slightly lower MTF but significantly higher DQEs than the CR system. The DQEs of the flat-panel system were found to increase with the exposure while those of the CR system decrease slightly with the exposure. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:98 / 110
页数:13
相关论文
共 50 条
  • [1] Image Quality Analysis of an aSi:H/CsI(Tl) Flat-Panel Based Digital Radiography System Using a Chest Phantom
    Kim, Sung-Hyun
    Kim, Do-Il
    Yoon, Jai-Woong
    Lee, Hyoung-Koo
    Suh, Tae-Seok
    Choe, Bo-Yong
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1559 - 1562
  • [2] Comparing image quality of flat-panel chest radiography with storage phosphor radiography and film-screen radiography
    Ganten, M
    Radeleff, B
    Kampschulte, A
    Daniels, MD
    Kauffmann, GW
    Hansmann, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (01) : 171 - 176
  • [3] The development and characterization of a dual-energy subtraction imaging system for chest radiography based on CsI:Tl amorphous silicon flat-panel technology
    Sabol, JM
    Avinash, GB
    Nicolas, F
    Claus, B
    Zhao, JG
    Dobbins, JT
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 399 - 408
  • [4] Comparison of a-Si:H/CsI flat-panel digital imaging systems with CR and CCD based systems -: Image quality measurements
    Liu, XM
    Shaw, CC
    Rong, XJ
    Lemacks, M
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 389 - 398
  • [5] Routine chest radiography with a flat-panel detector: Image quality with standard dose and dose reduction
    Strotzer, M
    Voelk, M
    Fruend, R
    Hamer, O
    Zorger, N
    Feuerbach, SG
    RADIOLOGY, 2001, 221 : 354 - 354
  • [6] Chest radiography with a flat-panel detector:: Image quality with dose reduction after copper filtration
    Hamer, OW
    Sirlin, CB
    Strotzer, M
    Borisch, I
    Zorger, N
    Feuerbach, S
    Völk, M
    RADIOLOGY, 2005, 237 (02) : 691 - 700
  • [7] Subjective image quality of digital lumbar spine radiographs acquired with a new flat-panel dedicated chest system versus computed radiography in supine patients
    Pärtan, G
    Newrkla, S
    Mahdi, T
    Mosser, H
    Pichler, L
    Hruby, W
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 1167 - 1167
  • [8] Contrast-to-noise and exposure measurements of an aSi:H/CsI(Tl) flat-panel based digital radiography system using a QC chest phantom
    Liu, XM
    Shaw, CC
    Balter, P
    Kappadath, SC
    Lai, CJ
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 826 - 832
  • [9] Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography
    Floyd, CE
    Warp, RJ
    Dobbins, JT
    Chotas, HG
    Baydush, AH
    Vargas-Voracek, R
    Ravin, CE
    RADIOLOGY, 2001, 218 (03) : 683 - 688
  • [10] Comparison of a-Se direct.-conversion and CsI(Tl) indirect-conversion flat-panel digital detectors: A clinical assessment of image quality for general radiography applications
    Barski, Lori L.
    Wang, Xiaohui
    Wandtke, John
    Waldman, David
    Davis, Delphine
    Foos, David H.
    Dupin, Michael
    Huang, Weidong
    Yorkston, John
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142