Detection and analysis of enamel cracks by ICG-NIR fluorescence dental imaging

被引:24
|
作者
Li, Zhongqiang [1 ]
Holamoge, Yoshita, V [1 ]
Li, Zheng [1 ]
Zaid, Waleed [2 ]
Osborn, Michelle L. [3 ]
Ramos, Alexandra [3 ]
Miller, Jacob T. [1 ]
Li, Yanping [4 ]
Yao, Shaomian [3 ]
Xu, Jian [1 ]
机构
[1] Louisiana State Univ, Coll Engn, Div Elect & Comp Engn, Baton Rouge, LA 70803 USA
[2] Louisiana State Univ, Sch Dent Oral & Maxillofacial Surg, Hlth Sci Ctr, Baton Rouge, LA 70803 USA
[3] Louisiana State Univ, Sch Vet Med, Dept Comparat Biomed Sci, Baton Rouge, LA 70803 USA
[4] Univ Saskatchewan, Sch Environm & Sustainabil, Saskatoon, SK, Canada
关键词
cracked tooth; crack depth; indocyanine green; near-infrared; fluorescence dental imaging; NEAR-INFRARED TRANSILLUMINATION; CT; TEETH;
D O I
10.1111/nyas.14374
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Cracked teeth are the third most common cause of tooth loss, but there is no reliable imaging tool for the diagnosis of cracks. Here, we demonstrate the feasibility of indocyanine green near-infrared fluorescence (ICG-NIRF) dental imaging for the detection of enamel cracks and enamel-dentin cracks in vitro in the first (ICG-NIRF-I, 700-950 nm) and second (ICG-NIRF-II, 950-1700 nm) imaging windows with transmission excitation light, and compared ICG-NIRF with conventional NIR illumination-II (NIRi-II) and X-ray imaging. Dentin cracks were detected by CT scan, while most enamel cracks, undetectable under X-ray imaging, were clearly visible in NIR images. We found that ICG-NIRF-II detected cracks more effectively than NIRi-II, and that light orientation is an important factor for crack detection: an angled exposure obtained better image contrast of cracks than parallel exposure, as it created a shadow under the crack. Crack depth could be evaluated from the crack shadow in ICG-NIRF and NIRi-II images; from this shadow we could determine crack depth and discriminate enamel-dentin cracks from craze lines. Cracks could be observed clearly from ICG-NIRF images with 1-min ICG tooth immersion, although longer ICG immersion produced images with greater contrast. Overall, our data show that ICG-NIRF dental imaging is a useful tool for diagnosing cracked teeth at an early stage.
引用
收藏
页码:52 / 63
页数:12
相关论文
共 50 条
  • [41] Noninvasive Detection and Monitoring of the Integrity of the Intestinal Barrier through NIR-II Fluorescence Imaging and Colorimetric Urinalysis
    Zhang, Li
    Feng, Lei
    Yang, Lin
    Wan, Hao
    ACS APPLIED MATERIALS & INTERFACES, 2025, 17 (09) : 13445 - 13460
  • [42] In vivo imaging of enamel by reflectance confocal microscopy (RCM): non-invasive analysis of dental surface
    Contaldo, Maria
    Serpico, Rosario
    Lucchese, Alberta
    ODONTOLOGY, 2014, 102 (02) : 325 - 329
  • [43] Pharmacokinetics of ICG and HPPH-car for detection of normal and tumor tissue using fluorescence, near-infrared continuous wave imaging
    Gurfinkel, M
    Thompson, AB
    Ralston, W
    Troy, TL
    Reynolds, JS
    Muggenberger, B
    Nikula, K
    Pandey, R
    Mayer, R
    Hawrysz, DJ
    Sevick-Muraca, EM
    BIOMEDICAL TOPICAL MEETINGS, TECHNICAL DIGEST, 2000, 38 : 245 - 248
  • [44] Detection of Dental Caries and Cracks with Quantitative Light-Induced Fluorescence in Comparison to Radiographic and Visual Examination: A Retrospective Case Study
    Oh, Song Hee
    Lee, Sae Rom
    Choi, Jin Young
    Choi, Yong Suk
    Kim, Seong Hun
    Yoon, Hong Cheol
    Nelson, Gerald
    SENSORS, 2021, 21 (05) : 1 - 15
  • [45] Evaluation of two imaging techniques: near-infrared transillumination and dental radiographs for the detection of early approximal enamel caries
    Maia, A. M. A.
    Karlsson, L.
    Margulis, W.
    Gomes, A. S. L.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (07) : 429 - 433
  • [46] Intraoperative use of ICG fluorescence imaging to reduce the risk of anastomotic leakage in colorectal surgery: a systematic review and meta-analysis
    R. Blanco-Colino
    E. Espin-Basany
    Techniques in Coloproctology, 2018, 22 : 15 - 23
  • [47] Intraoperative use of ICG fluorescence imaging to reduce the risk of anastomotic leakage in colorectal surgery: a systematic review and meta-analysis
    Blanco-Colino, R.
    Espin-Basany, E.
    TECHNIQUES IN COLOPROCTOLOGY, 2018, 22 (01) : 15 - 23
  • [48] Intraoperative Near-infrared Fluorescence (NIR) Imaging With Indocyanine Green (ICG) Can Identify Bone and Soft Tissue Sarcomas Which May Provide Guidance for Oncological Resection
    Nicoli, Fabio
    Saleh, Daniel B.
    Baljer, Bence
    Chan, Corey D.
    Beckingsale, Tom
    Ghosh, Kanishka M.
    Ragbir, Maniram
    Rankin, Kenneth S.
    ANNALS OF SURGERY, 2021, 273 (02) : E63 - E68
  • [49] Fe-Doped Carbon Dots as NIR-II Fluorescence Probe for In Vivo Gastric Imaging and pH Detection
    Ci, Qiaoqiao
    Wang, Yuanyuan
    Wu, Ben
    Coy, Emerson
    Li, Jiao Jiao
    Jiang, Daoyong
    Zhang, Pengfei
    Wang, Guocheng
    ADVANCED SCIENCE, 2023, 10 (07)
  • [50] Visualizing Detection of Diabetic Liver Injury by a Biomarker-Activatable Probe via NIR-II Fluorescence Imaging
    Chen, Zikang
    Zhang, Zhichao
    Zeng, Fang
    Wu, Shuizhu
    CHEMICAL & BIOMEDICAL IMAGING, 2023, 1 (08): : 716 - 724