Flow structure of subcooled boiling water flow in a subchannel of 3x3 rod bundles

被引:54
|
作者
Yun, Byong-Jo [2 ]
Park, Goon-Cherl [3 ]
Julia, J. Enrique [1 ]
Hibiki, Takashi [4 ]
机构
[1] Univ Jaume 1, Dept Ingn Mecan & Construcc, Castellon de La Plana 12071, Spain
[2] Korea Atom Energy Res Inst, Taejon 305600, South Korea
[3] Seoul Natl Univ, Dept Nucl Engn, Seoul 151742, South Korea
[4] Purdue Univ, Sch Nucl Engn, W Lafayette, IN 47907 USA
关键词
rod bundle; subchannel; subcooled boiling flow; local measurements; drift-flux model; interfacial area concentration;
D O I
10.3327/jnst.45.402
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this paper, the interfacial flow structure of subcooled water boiling flow in a subchannel of 3 x 3 rod bundles is presented. The 9 rods are positioned in a quadrangular assembly with a rod diameter of 8.2 mm and a pitch distance of 16.6 mm. Local void fraction, interfacial area concentration, interfacial velocity, Sauter mean diameter, and liquid velocity have been measured using a conductivity probe and a Pilot tube in 20 locations inside one of the subchannels. A total of 53 flow conditions have been considered in the experimental dataset at atmospheric pressure conditions with a mass flow rate, heat flux, inlet temperature, and subcooled temperature ranges of 250-522 kg/m(2) s, 25-185 kW/m(2), 96.6-104.9 degrees C, and 2-11 K, respectively. The dataset has been used to analyze the effect of the heat flux and mass flow rate on the local flow parameters. In addition, the area-averaged data integrated over the whole subchannel have been used to validate some of the distribution parameter and drift velocity constitutive equations and interfacial area concentration correlations most used in the literature.
引用
收藏
页码:402 / 422
页数:21
相关论文
共 50 条
  • [31] Bubble behavior in subcooled flow boiling of water at low pressures and low flow rates
    Prodanovic, V
    Fraser, D
    Salcudean, M
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2002, 28 (01) : 1 - 19
  • [32] Simulations of air-water flow and subcooled boiling flow using the CUPID code
    Park, Ik Kyu
    Yoon, Han Young
    Cho, Hyoung Kyu
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2013, 50 (08) : 813 - 827
  • [34] FIDAS - A 3-FLUID SUBCHANNEL CODE FOR DRYOUT PREDICTION IN ROD BUNDLES
    SAKAI, T
    RUMMENS, HEC
    SUGAWARA, S
    10TH ANNUAL CONFERENCE 1989 - CANADIAN NUCLEAR SOCIETY, PROCEEDINGS, VOL 2, 1989, : F19 - F24
  • [35] Assessment of subchannel flow mixing coefficients for wire-wrapped hexagonal fuel rod bundles
    Choi, Sun Rock
    Kim, Hyungmo
    Chang, Seok-Kyu
    Choi, Hae Seob
    Euh, Dong-Jin
    Lee, Hyeong-Yeon
    Yang, Won Sik
    ANNALS OF NUCLEAR ENERGY, 2022, 166
  • [37] Numerical Investigation to Effect of Spacer Grid on the Subcooled Flow Boiling in Single Rod Channel
    Zhang T.
    Lü M.
    Liu H.
    Zhi C.
    Chen P.
    Liu Y.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2020, 54 (12): : 116 - 124
  • [38] THE STRUCTURE OF TURBULENT-FLOW THROUGH ROD BUNDLES
    REHME, K
    NUCLEAR ENGINEERING AND DESIGN, 1987, 99 : 141 - 154
  • [39] Numerical investigation of the effect of mixing vanes on subcooled boiling in a 3 x 3 rod bundle channel with spacer grid
    Yang, Peng
    Zhang, Ting
    Hu, Lulu
    Liu, Liu
    Liu, Yingwen
    ENERGY, 2021, 236
  • [40] VOID FRACTION AND INCIPIENT POINT OF BOILING DURING SUBCOOLED NUCLEATE FLOW BOILING OF WATER
    UNAL, HC
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1977, 20 (04) : 409 - 419