Orthodontic mini-implant stability at different insertion depths Sensitivity of three stability measurement methods

被引:0
|
作者
Nienkemper, Manuel [1 ]
Santel, Natascha [1 ]
Hoenscheid, Ralf [1 ]
Drescher, Dieter [1 ]
机构
[1] Univ Dusseldorf, Dept Orthodont, Moorenstr 5, D-40225 Dusseldorf, Germany
关键词
Orthodontics; Skeletal anchorage; Insertion depth; Mini-implants; Models animal; RESONANCE FREQUENCY-ANALYSIS; DAMPING CAPACITY ASSESSMENT; IN-VITRO; INTERFACE; DIAMETER; IMPACT;
D O I
10.1007/s00056-016-0036-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this work was to evaluate the influence of insertion depth on the stability of orthodontic mini-implants. Sensitivity of three different methods to measure implant stability based on differences in insertion depth were determined. A total of 82 mini-implants (2 x 9 mm) were inserted into pelvic bone of Swabian Hall pigs. Each implant was inserted stepwise to depths of 4, 5, 6, 7, and 8 mm. At each of these depths, three different methods were used to measure implant stability, including maximum insertion torque (MIT), resonance frequency analysis (RFA), and Periotest(A (R)). Differences between the recorded values were statistically analyzed and the methods tested for correlations. Almost linear changes from each insertion depth were measured with the values of RFA [implant stability quotient (ISQ) values range from 1-100], which increased from 6.95 +/- 2.85 ISQ at 4 mm to 34.63 +/- 5.51 ISQ at 8 mm, and with those of Periotest(A (R)) [periotest values (PTV) range from -8 to 50], which decreased from 13.24 +/- 4.03 PTV to -2.89 +/- 1.87 PTV. Both methods were found to record highly significant (p < 0.0001) changes for each additional millimeter of insertion depth. The MIT increased significantly (p < 0.0001) from 153.67 +/- 69.32 Nmm to 261 +/- 103.73 Nmm between 4 and 5 mm of insertion depth but no further significant changes were observed as the implants were driven deeper. The RFA and Periotest(A (R)) values were highly correlated (r = -0.907). Mini-implant stability varies significantly with insertion depth. The RFA and the Periotest(A (R)) yielded a linear relationship between stability and insertion depth. MIT does not appear to be an adequate method to determine implant stability based on insertion depth.
引用
收藏
页码:296 / 303
页数:8
相关论文
共 50 条
  • [41] Impact of implant design on primary stability of orthodontic mini-implants
    Wilmes, Benedict
    Ottenstreuer, Stephanie
    Su, Yu-Yu
    Drescher, Dieter
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2008, 69 (01): : 42 - 50
  • [42] Impact of mini-implant length on stability at the initial healing period: a controlled clinical study
    Manuel Nienkemper
    Benedict Wilmes
    Alexander Pauls
    Dieter Drescher
    Head & Face Medicine, 9
  • [43] Impact of mini-implant length on stability at the initial healing period: a controlled clinical study
    Nienkemper, Manuel
    Wilmes, Benedict
    Pauls, Alexander
    Drescher, Dieter
    HEAD & FACE MEDICINE, 2013, 9
  • [44] Effect of photobiomodulation therapy on mini-implant stability: a systematic review and meta-analysis
    Bo Zhang
    Xinqi Huang
    Sibei Huo
    Chenghao Zhang
    Xiao Cen
    Zhihe Zhao
    Lasers in Medical Science, 2021, 36 : 1557 - 1566
  • [45] Effect of photobiomodulation therapy on mini-implant stability: a systematic review and meta-analysis
    Zhang, Bo
    Huang, Xinqi
    Huo, Sibei
    Zhang, Chenghao
    Cen, Xiao
    Zhao, Zhihe
    LASERS IN MEDICAL SCIENCE, 2021, 36 (08) : 1557 - 1566
  • [46] Effects of Three Different Orthodontic Treatment Methods on the Stability of Mandibular Incisor Alignment
    Gorucu-Coskuner, Hande
    Atik, Ezgi
    Kocadereli, Ilken
    JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2017, 41 (06) : 486 - 493
  • [47] Effect of mini-implant length and diameter on primary stability under loading with two force levels
    Chatzigianni, Athina
    Keilig, Ludger
    Reimann, Susanne
    Eliades, Theodore
    Bourauel, Christoph
    EUROPEAN JOURNAL OF ORTHODONTICS, 2011, 33 (04) : 381 - 387
  • [48] Two-dimensional radiographic and clinical references of the tooth crown for orthodontic mini-implant insertion: A guide-free technique
    Barros, Sergio Estelita
    Janson, Guilherme
    Chiqueto, Kelly
    Garib, Daniela Gamba
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (05): : E8 - E16
  • [49] Comparing the Primary Stability of Three Different Orthodontic Mini-Implants with Various Dimensions on Artificial Bone
    Mohammed, Haneen I.
    Al-Sheakli, Iman I.
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (01): : 128 - 134
  • [50] Impact of Insertion Depth and Predrilling Diameter on Primary Stability of Orthodontic Mini-implants
    Wilmes, Benedict
    Drescher, Dieter
    ANGLE ORTHODONTIST, 2009, 79 (04) : 609 - 614