Orthodontic mini-implant stability at different insertion depths Sensitivity of three stability measurement methods

被引:0
|
作者
Nienkemper, Manuel [1 ]
Santel, Natascha [1 ]
Hoenscheid, Ralf [1 ]
Drescher, Dieter [1 ]
机构
[1] Univ Dusseldorf, Dept Orthodont, Moorenstr 5, D-40225 Dusseldorf, Germany
关键词
Orthodontics; Skeletal anchorage; Insertion depth; Mini-implants; Models animal; RESONANCE FREQUENCY-ANALYSIS; DAMPING CAPACITY ASSESSMENT; IN-VITRO; INTERFACE; DIAMETER; IMPACT;
D O I
10.1007/s00056-016-0036-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this work was to evaluate the influence of insertion depth on the stability of orthodontic mini-implants. Sensitivity of three different methods to measure implant stability based on differences in insertion depth were determined. A total of 82 mini-implants (2 x 9 mm) were inserted into pelvic bone of Swabian Hall pigs. Each implant was inserted stepwise to depths of 4, 5, 6, 7, and 8 mm. At each of these depths, three different methods were used to measure implant stability, including maximum insertion torque (MIT), resonance frequency analysis (RFA), and Periotest(A (R)). Differences between the recorded values were statistically analyzed and the methods tested for correlations. Almost linear changes from each insertion depth were measured with the values of RFA [implant stability quotient (ISQ) values range from 1-100], which increased from 6.95 +/- 2.85 ISQ at 4 mm to 34.63 +/- 5.51 ISQ at 8 mm, and with those of Periotest(A (R)) [periotest values (PTV) range from -8 to 50], which decreased from 13.24 +/- 4.03 PTV to -2.89 +/- 1.87 PTV. Both methods were found to record highly significant (p < 0.0001) changes for each additional millimeter of insertion depth. The MIT increased significantly (p < 0.0001) from 153.67 +/- 69.32 Nmm to 261 +/- 103.73 Nmm between 4 and 5 mm of insertion depth but no further significant changes were observed as the implants were driven deeper. The RFA and Periotest(A (R)) values were highly correlated (r = -0.907). Mini-implant stability varies significantly with insertion depth. The RFA and the Periotest(A (R)) yielded a linear relationship between stability and insertion depth. MIT does not appear to be an adequate method to determine implant stability based on insertion depth.
引用
收藏
页码:296 / 303
页数:8
相关论文
共 50 条
  • [1] Orthodontic mini-implant stability at different insertion depths: Sensitivity of three stability measurement methods; [Stabilität orthodontischer Mini-Implantate bei verschiedenen Insertionstiefen: Sensitivität dreier Stabilitätsmessmethoden]
    Nienkemper M.
    Santel N.
    Hönscheid R.
    Drescher D.
    Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2016, 77 (4): : 296 - 303
  • [2] Biomechanical effect of abutment on stability of orthodontic mini-implant
    Motoyoshi, M
    Yano, S
    Tsuruoka, T
    Shimizu, N
    CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) : 480 - 485
  • [3] Orthodontic mini-implant stability and the ratio of pilot hole implant diameter
    Uemura, Miwa
    Motoyoshi, Mitsuru
    Yano, Shinya
    Sakaguchi, Masahito
    Igarashi, Yu
    Shimizu, Noriyoshi
    EUROPEAN JOURNAL OF ORTHODONTICS, 2012, 34 (01) : 52 - 56
  • [4] Mechanical influence of thread pitch on orthodontic mini-implant stability
    da Cunha, Amanda Carneiro
    Ayres de Freitas, Amanda Osorio
    Marquezan, Mariana
    Nojima, Lincoln Issamu
    BRAZILIAN ORAL RESEARCH, 2015, 29 (01): : 1 - 6
  • [5] A novel technique for measurement of orthodontic mini-implant stability using the Osstell ISQ device
    Hosein, Yara K.
    Dixon, S. Jeffrey
    Rizkalla, Amin S.
    Tassi, Ali
    ANGLE ORTHODONTIST, 2019, 89 (02) : 284 - 291
  • [6] The effect of different orthodontic mini-implant brands and geometry on primary stability (an in vitro study)
    Abdalla, Khanda Latif
    Mahmood, Trefa Mohammed Ali
    HELIYON, 2023, 9 (09)
  • [7] Experimental & FEM Analysis of Orthodontic Mini-Implant Design on Primary Stability
    Mesic, Elmedin
    Muratovic, Enis
    Redzepagic-Vrazalica, Lejla
    Pervan, Nedim
    Muminovic, Adis J.
    Delic, Muamer
    Glusac, Mirza
    APPLIED SCIENCES-BASEL, 2021, 11 (12):
  • [8] A Comparison of the Mechanical Measures Used for Assessing Orthodontic Mini-Implant Stability
    Hosein, Yara K.
    Dixon, S. Jeffrey
    Rizkalla, Amin S.
    Tassi, Ali
    IMPLANT DENTISTRY, 2017, 26 (02) : 225 - 231
  • [9] Measurement of mini-implant stability using resonance frequency analysis
    Nienkemper, Manuel
    Wilmes, Benedict
    Panayotidis, Agamemnon
    Pauls, Alexander
    Golubovic, Vladimir
    Schwarz, Frank
    Drescher, Dieter
    ANGLE ORTHODONTIST, 2013, 83 (02) : 230 - 238
  • [10] Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2
    Hong, Christine
    Peter Truong
    Ha Na Song
    Wu, Benjamin M.
    Moon, Won
    ANGLE ORTHODONTIST, 2011, 81 (06) : 1001 - 1009