Hydrophilic interaction liquid chromatography coupled to high-resolution mass spectrometry to determine artificial sweeteners in environmental waters

被引:16
|
作者
Salas, Daniela [1 ]
Borrull, Francesc [1 ]
Fontanals, Nuria [1 ]
Maria Marce, Rosa [1 ]
机构
[1] Univ Rovira & Virgili, Dept Analyt Chem & Organ Chem, E-43007 Tarragona, Spain
关键词
Artificial sweeteners; Hydrophilic interaction liquid chromatography; High-resolution mass spectrometry; Environmental waters; SOLID-PHASE EXTRACTION; SURFACE WATERS; SUCRALOSE; PERFORMANCE; SAMPLES;
D O I
10.1007/s00216-014-8330-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Artificial sweeteners are food additives employed as sugar substitutes which are now considered to be emerging organic contaminants. In the present study, a method is developed for the determination of a group of artificial sweeteners in environmental waters. Considering the polar and hydrophilic character of these compounds, hydrophilic interaction liquid chromatography is proposed for their separation as an alternative to traditional reversed-phase liquid chromatography. Two stationary phases with different chemistry were compared for this purpose. For the detection of the analytes, high-resolution mass spectrometry (Orbitrap) was employed to take advantage of its benefits in terms of reliable quantification and confirmation for the measurement of accurate masses. Solid-phase extraction was chosen as the sample treatment, in which the extract in a mixture of NH4OH:MeOH:ACN (1:4:15) was directly injected into the chromatographic system, simplifying the analytical procedure. The optimized method was validated on river and waste water samples. For example, in the case of effluent water samples, limits of detection ranged from 0.002 to 0.7 mu g/L and limits of quantification ranged from 0.004 to 1.5 mu g/L. Apparent (whole method) recoveries ranged from 57 to 74 % with intra-day precision (%RSD, n = 5) ranging from 6 to 25 %. The method was successfully applied to water samples from different rivers in Catalonia and different waste water treatment plants in Tarragona. Acesulfame, cyclamate, saccharine and sucralose were found in several samples.
引用
收藏
页码:4277 / 4285
页数:9
相关论文
共 50 条
  • [31] Ultra-Trace Analysis of Cyanotoxins by Liquid Chromatography Coupled to High-Resolution Mass Spectrometry
    Filatova, Daria
    Nunez, Oscar
    Farre, Marinella
    TOXINS, 2020, 12 (04)
  • [32] Analysis of (Functionalized) Fullerenes in Water Samples by Liquid Chromatography Coupled to High-Resolution Mass Spectrometry
    Kolkman, Annemieke
    Emke, Erik
    Bauerlein, Patrick S.
    Carboni, Andrea
    Diem Truc Tran
    ter Laak, Thomas L.
    van Wezel, Annemarie P.
    de Voogt, Pim
    ANALYTICAL CHEMISTRY, 2013, 85 (12) : 5867 - 5874
  • [33] Cannabinoid Profiling of Hemp Seed Oil by Liquid Chromatography Coupled to High-Resolution Mass Spectrometry
    Citti, Cinzia
    Linciano, Pasquale
    Panseri, Sara
    Vezzalini, Francesca
    Forni, Flavio
    Vandelli, Maria Angela
    Cannazza, Giuseppe
    FRONTIERS IN PLANT SCIENCE, 2019, 10
  • [34] Peptide retention prediction using hydrophilic interaction liquid chromatography coupled to mass spectrometry
    Badgett, Majors J.
    Boyes, Barry
    Orlando, Ron
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1537 : 58 - 65
  • [35] Hydrophilic interaction liquid chromatography coupled with mass spectrometry for metabolomic analysis of Escherichia coli
    Wang Xiyue
    Gao Peng
    Xu Guowang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (10) : 1084 - 1093
  • [36] Target screening of plant secondary metabolites in river waters by liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS)
    Nanusha, Mulatu Yohannes
    Krauss, Martin
    Schoensee, Carina D.
    Gunthardt, Barbara F.
    Bucheli, Thomas D.
    Brack, Werner
    ENVIRONMENTAL SCIENCES EUROPE, 2020, 32 (01)
  • [37] Simultaneous screening for lipophilic and hydrophilic toxins in marine harmful algae using a serially coupled reversed-phase and hydrophilic interaction liquid chromatography separation system with high-resolution mass spectrometry
    Chen, Junhui
    Gao, Liyuan
    Li, Zhaoyong
    Wang, Shuai
    Li, Jingxi
    Cao, Wei
    Sun, Chengjun
    Zheng, Li
    Wang, Xiaoru
    ANALYTICA CHIMICA ACTA, 2016, 914 : 117 - 126
  • [38] Quantitative determination of DNA adducts using liquid chromatography electrospray ionization mass spectrometry and liquid chromatography high-resolution inductively coupled plasma mass spectrometry
    Siethoff, C
    Feldmann, I
    Jakubowski, N
    Linscheid, M
    JOURNAL OF MASS SPECTROMETRY, 1999, 34 (04): : 421 - 426
  • [39] Hydrophilic interaction and reversed phase mixed-mode liquid chromatography coupled to high resolution tandem mass spectrometry for polar lipids analysis
    Granafei, Sara
    Azzone, Pietro
    Spinelli, Vito Alessandro
    Losito, Ilario
    Palmisano, Francesco
    Cataldi, Tommaso R. I.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1477 : 47 - 55
  • [40] Investigating the presence of omeprazole in waters by liquid chromatography coupled to low and high resolution mass spectrometry: degradation experiments
    Boix, C.
    Ibanez, M.
    Sancho, J. V.
    Niessen, W. M. A.
    Hernandez, F.
    JOURNAL OF MASS SPECTROMETRY, 2013, 48 (10): : 1091 - 1100