Voltammetric determination of nitric oxide using a glassy carbon electrode modified with a nanohybrid consisting of myoglobin, gold nanorods, and reduced graphene oxide

被引:16
|
作者
Marlinda, Ab Rahman [1 ]
Pandikumar, Alagarsamy [2 ,3 ]
Jayabal, Subramaniam [1 ]
Yusoff, Norazriena [1 ]
Suriani, Abu Bakar [4 ]
Huang, Nay Ming [1 ]
机构
[1] Univ Malaya, Dept Phys, Low Dimens Mat Res Ctr, Fac Sci, Kuala Lumpur 50603, Malaysia
[2] SRM Univ, Res Inst, Chennai 603203, Tamil Nadu, India
[3] SRM Univ, Dept Chem, Chennai 603203, Tamil Nadu, India
[4] Univ Pendidikan Sultan Idris, Fac Sci & Math, Nanotechnol Res Ctr, Tanjong Malim 35900, Perak, Malaysia
关键词
Electroanalysis; Biosensor; Nanocomposite; Localized surface plasmon resonance; LSPR; Linear sweep voltammetry; X-ray diffractometry; X-ray photoelectron spectroscopy; Capillary dilatator; SENSOR; OXIDATION; PLATFORM; NAFION; FILM;
D O I
10.1007/s00604-016-1922-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Myoglobin-modified gold nanorods incorporating reduced graphene oxide (rGO) were fabricated and deposited on a glassy carbon electrode (GCE) to obtain a sensor for nitric oxide (NO). The Mb-AuNR/rGO nanohybrid showed a transverse localized surface plasmon resonance (LSPR) band with a peak at 508 nm, and a longitudinal LSPR band at 724 nm. The AuNRs have an average length of 38 +/- 3 nm and a width of 11 +/- 1 nm. The GCE modified with the nanohybrid is shown to be a viable sensor for the determination of NO by linear sweep voltammetry. Its electrocatalytic response toward the oxidation of NO is distinctly enhanced compared to other electrodes. The sensor, best operated at a working voltage of 0.85 V (vs. SCE), showed two linear response ranges (from 10 to100 mu M, and from 100 to 1000 mu M), with a detection limit of 5.5 mu M. Furthermore, it exhibits excellent selectivity for NO over common interferents such as NaNO3, and also over electroactive species such as ascorbate, dopamine, glucose, and uric acid. These properties make it a promising tool for the detection of NO in situations such as capillary and pulmonary hypertension and embolism, and during vasodilation.
引用
收藏
页码:3077 / 3085
页数:9
相关论文
共 50 条
  • [21] A glassy carbon electrode modified with carbon nanotubes and reduced graphene oxide decorated with platinum-gold nanoparticles for voltammetric aptasensing of urea
    Hamed Momenzadeh
    Azadeh Azadbakht
    Microchimica Acta, 2017, 184 : 4685 - 4694
  • [22] A glassy carbon electrode modified with carbon nanotubes and reduced graphene oxide decorated with platinum-gold nanoparticles for voltammetric aptasensing of urea
    Momenzadeh, Hamed
    Azadbakht, Azadeh
    MICROCHIMICA ACTA, 2017, 184 (12) : 4685 - 4694
  • [23] Selective Voltammetric Determination of Paracetamol and Acyclovir on an Electrode Modified with Reduced Graphene Oxide and Gold Particles
    Shaidarova, L. G.
    Pozdnyak, A. A.
    Gedmina, A. V.
    Budnikov, H. C.
    UCHENYE ZAPISKI KAZANSKOGO UNIVERSITETA-SERIYA ESTESTVENNYE NAUKI, 2024, 166 (03): : 401 - 413
  • [24] A glassy carbon electrode modified with a composite consisting of gold nanoparticle, reduced graphene oxide and poly(L-arginine) for simultaneous voltammetric determination of dopamine, serotonin and L-tryptophan
    Khan, Md. Zaved H.
    Liu, Xiaoqiang
    Tang, Yunfei
    Zhu, Jinhua
    Hu, Weiping
    Liu, Xiuhua
    MICROCHIMICA ACTA, 2018, 185 (09)
  • [25] A glassy carbon electrode modified with a composite consisting of gold nanoparticle, reduced graphene oxide and poly(L-arginine) for simultaneous voltammetric determination of dopamine, serotonin and L-tryptophan
    Md. Zaved H. Khan
    Xiaoqiang Liu
    Yunfei Tang
    Jinhua Zhu
    Weiping Hu
    Xiuhua Liu
    Microchimica Acta, 2018, 185
  • [26] Voltammetric determination of palmitic acid by electrode modified with reduced graphene oxide
    Chin Boon Ching
    Jaafar Abdullah
    Nor Azah Yusof
    Journal of Food Science and Technology, 2022, 59 : 1053 - 1062
  • [27] Impedimetric Salmonella aptasensor using a glassy carbon electrode modified with an electrodeposited composite consisting of reduced graphene oxide and carbon nanotubes
    Fei Jia
    Nuo Duan
    Shijia Wu
    Ruitong Dai
    Zhouping Wang
    Xingmin Li
    Microchimica Acta, 2016, 183 : 337 - 344
  • [28] Impedimetric Salmonella aptasensor using a glassy carbon electrode modified with an electrodeposited composite consisting of reduced graphene oxide and carbon nanotubes
    Jia, Fei
    Duan, Nuo
    Wu, Shijia
    Dai, Ruitong
    Wang, Zhouping
    Li, Xingmin
    MICROCHIMICA ACTA, 2016, 183 (01) : 337 - 344
  • [29] Voltammetric determination of palmitic acid by electrode modified with reduced graphene oxide
    Ching, Chin Boon
    Abdullah, Jaafar
    Yusof, Nor Azah
    JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 2022, 59 (03): : 1053 - 1062
  • [30] Modifying a Glassy Carbon Electrode with Reduced Graphene Oxide for the Determination of Levofloxacin with a Glassy
    Ghanbari, Mohammad Hossein
    Rahimi-Nasrabadi, Mehdi
    Sobati, Hossein
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (02): : 189 - 200