Voltammetric determination of nitric oxide using a glassy carbon electrode modified with a nanohybrid consisting of myoglobin, gold nanorods, and reduced graphene oxide

被引:16
|
作者
Marlinda, Ab Rahman [1 ]
Pandikumar, Alagarsamy [2 ,3 ]
Jayabal, Subramaniam [1 ]
Yusoff, Norazriena [1 ]
Suriani, Abu Bakar [4 ]
Huang, Nay Ming [1 ]
机构
[1] Univ Malaya, Dept Phys, Low Dimens Mat Res Ctr, Fac Sci, Kuala Lumpur 50603, Malaysia
[2] SRM Univ, Res Inst, Chennai 603203, Tamil Nadu, India
[3] SRM Univ, Dept Chem, Chennai 603203, Tamil Nadu, India
[4] Univ Pendidikan Sultan Idris, Fac Sci & Math, Nanotechnol Res Ctr, Tanjong Malim 35900, Perak, Malaysia
关键词
Electroanalysis; Biosensor; Nanocomposite; Localized surface plasmon resonance; LSPR; Linear sweep voltammetry; X-ray diffractometry; X-ray photoelectron spectroscopy; Capillary dilatator; SENSOR; OXIDATION; PLATFORM; NAFION; FILM;
D O I
10.1007/s00604-016-1922-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Myoglobin-modified gold nanorods incorporating reduced graphene oxide (rGO) were fabricated and deposited on a glassy carbon electrode (GCE) to obtain a sensor for nitric oxide (NO). The Mb-AuNR/rGO nanohybrid showed a transverse localized surface plasmon resonance (LSPR) band with a peak at 508 nm, and a longitudinal LSPR band at 724 nm. The AuNRs have an average length of 38 +/- 3 nm and a width of 11 +/- 1 nm. The GCE modified with the nanohybrid is shown to be a viable sensor for the determination of NO by linear sweep voltammetry. Its electrocatalytic response toward the oxidation of NO is distinctly enhanced compared to other electrodes. The sensor, best operated at a working voltage of 0.85 V (vs. SCE), showed two linear response ranges (from 10 to100 mu M, and from 100 to 1000 mu M), with a detection limit of 5.5 mu M. Furthermore, it exhibits excellent selectivity for NO over common interferents such as NaNO3, and also over electroactive species such as ascorbate, dopamine, glucose, and uric acid. These properties make it a promising tool for the detection of NO in situations such as capillary and pulmonary hypertension and embolism, and during vasodilation.
引用
收藏
页码:3077 / 3085
页数:9
相关论文
共 50 条
  • [1] Voltammetric determination of nitric oxide using a glassy carbon electrode modified with a nanohybrid consisting of myoglobin, gold nanorods, and reduced graphene oxide
    Ab Rahman Marlinda
    Alagarsamy Pandikumar
    Subramaniam Jayabal
    Norazriena Yusoff
    Abu Bakar Suriani
    Nay Ming Huang
    Microchimica Acta, 2016, 183 : 3077 - 3085
  • [2] Amperometric detection of nitric oxide using a glassy carbon electrode modified with gold nanoparticles incorporated into a nanohybrid composed of reduced graphene oxide and Nafion
    Yusoff, Norazriena
    Rameshkumar, Perumal
    Shahid, Muhammad Mehmood
    Huang, Sheng-Tung
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2017, 184 (09) : 3291 - 3299
  • [3] Amperometric detection of nitric oxide using a glassy carbon electrode modified with gold nanoparticles incorporated into a nanohybrid composed of reduced graphene oxide and Nafion
    Norazriena Yusoff
    Perumal Rameshkumar
    Muhammad Mehmood Shahid
    Sheng-Tung Huang
    Nay Ming Huang
    Microchimica Acta, 2017, 184 : 3291 - 3299
  • [4] Voltammetric Determination of Gallic Acid with a Glassy Carbon Electrode modified with Reduced Graphene Oxide
    Lisnund, Sireerat
    Blay, Vincent
    Chansaenpak, Kantapat
    Pinyou, Piyanut
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (08): : 7214 - 7227
  • [5] Voltammetric determination of catechol based on a glassy carbon electrode modified with a composite consisting of graphene oxide and polymelamine
    Palanisamy, Selvakumar
    Ramaraj, Sayee Kannan
    Chen, Shen-Ming
    Velusamy, Vijayalakshmi
    Yang, Thomas C. K.
    Chen, Tse-Wei
    MICROCHIMICA ACTA, 2017, 184 (04) : 1051 - 1057
  • [6] Voltammetric determination of caffeic acid by using a glassy carbon electrode modified with a chitosan-protected nanohybrid composed of carbon black and reduced graphene oxide
    Kannaiyan Pandian
    Dhamodaran Mohana Soundari
    Panneerselvam Rudra Showdri
    Jayaprakash Kalaiyarasi
    Subash C. B. Gopinath
    Microchimica Acta, 2019, 186
  • [7] Voltammetric determination of catechol based on a glassy carbon electrode modified with a composite consisting of graphene oxide and polymelamine
    Selvakumar Palanisamy
    Sayee Kannan Ramaraj
    Shen-Ming Chen
    Vijayalakshmi Velusamy
    Thomas C. K. Yang
    Tse-Wei Chen
    Microchimica Acta, 2017, 184 : 1051 - 1057
  • [8] Sensitive Voltammetric Determination of Baicalein at Thermally Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Zhang, Yanmin
    He, Langchong
    ELECTROANALYSIS, 2013, 25 (09) : 2136 - 2144
  • [9] Gold nanorods-graphene oxide nanocomposite incorporated carbon nanotube paste modified glassy carbon electrode for voltammetric determination of indomethacin
    Arvand, Majid
    Gholizadeh, Tahereh M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 186 : 622 - 632
  • [10] Electrochemical Behavior and Voltammetric Determination of Curcumin at Electrochemically Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Ouyang, Xiaoyan
    Ma, Jing
    Li, Lingzhi
    Zhang, Yanmin
    ELECTROANALYSIS, 2016, 28 (04) : 749 - 756