Development of a low-pressure loss PM2.5 filter for building natural ventilation

被引:1
|
作者
Silva, Ana F. [1 ]
da Graca, Guilherme Carrilho [1 ]
机构
[1] Univ Lisbon, Fac Ciencias, Inst Dom Luiz, Lisbon, Portugal
关键词
PM2; 5; Natural ventilation; Air filter; Electrostatic precipitator; Airflow optimization; FINE-PARTICLE POLLUTION; NEGATIVE DC CORONA; ELECTROSTATIC PRECIPITATOR; COLLECTION EFFICIENCY; ENERGY-CONSUMPTION; RELATIVE-HUMIDITY; DESIGN PARAMETERS; 10; QUESTIONS; AIR-QUALITY; INDOOR;
D O I
10.1016/j.buildenv.2022.108798
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the development and experimental testing of an innovative low-pressure loss PM2.5 filter channel that can be integrated in building facades. This indoor-outdoor filter uses electrostatic precipitation (ESP) to reduce outdoor PM2.5 ingress into the indoor environment while ensuring the low airflow resistance that natural ventilation systems require. The filter uses a "U" shaped channel that allows for the integration of ESP and an acoustic attenuation component in a device that fits in the shallow depth of common building facades. The proposed filter device has a 0.5 m height, a 0.4 m width and 0.3 m depth. A 0.1 m opening height allows for a nominal airflow of 70 m3/h with an average inflow velocity of 0.5 m/s. The development and testing work presented in this paper used a combination of laboratory experiments and computational fluid dynamics simulations. Experimental results show that the PM2.5 collection efficiency of the device is more than 60%.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Sampling and conditioning artifacts of PM2.5 in filter-based samplers
    Liu, Chun-Nan
    Lin, Sih-Fan
    Awasthi, Amit
    Tsai, Chuen-Jinn
    Wu, Yueh-Chuen
    Chen, Chung-Fang
    ATMOSPHERIC ENVIRONMENT, 2014, 85 : 48 - 53
  • [42] EVALUATION OF FILTER MEDIA OPTIONS FOR HIGH VOLUME PM2.5 SAMPLING
    Li, H.
    Wanjura, J. D.
    Faulkner, W. B.
    Lacey, R. E.
    APPLIED ENGINEERING IN AGRICULTURE, 2019, 35 (02) : 205 - 209
  • [43] Cleanable Air Filter Transferring Moisture and Effectively Capturing PM2.5
    Zhao, Xinglei
    Li, Yuyao
    Hua, Ting
    Jiang, Pan
    Yin, Xia
    Yu, Jianyong
    Ding, Bin
    SMALL, 2017, 13 (11)
  • [44] VARGO SUPER FILTER - A FILTER FOR LOW-PRESSURE FILTRATION
    GAVELIN, G
    SVENSK PAPPERSTIDNING-NORDISK CELLULOSA, 1972, 75 (06): : 221 - &
  • [45] An efficient reduced graphene-oxide filter for PM2.5 removal
    Jung, Wonji
    Lee, Jeong Seok
    Han, Seonggeun
    Ko, Seung Hwan
    Kim, Taewoo
    Kim, Yong Hyup
    JOURNAL OF MATERIALS CHEMISTRY A, 2018, 6 (35) : 16975 - 16982
  • [46] PM2.5 associates with blood pressure: a Mendelian randomization analysis
    Bao, Minghui
    Li, Haotong
    Zhang, Yan
    Li, Jianping
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH, 2024, 34 (12) : 4190 - 4201
  • [47] Blood pressure associated with PM2.5 in a cardiac rehabilitation study
    Zanobetti, A
    Schwartz, J
    Sher, D
    Eagan-Bengston, E
    Gates, KA
    Barr, M
    Jacobson, M
    Gold, D
    EPIDEMIOLOGY, 2002, 13 (04) : S169 - S169
  • [48] How May Building Morphology Influence Pedestrians' Exposure to PM2.5?
    Karale, Yogita
    Yuan, May
    APPLIED SCIENCES-BASEL, 2024, 14 (12):
  • [49] The effect of horizontal elements and building orientation on PM2.5 concentration in classrooms
    Tikul, Nachawit
    Hokpunna, Apiruk
    Chawana, Panphat
    FRONTIERS OF ARCHITECTURAL RESEARCH, 2023, 12 (04) : 775 - 787
  • [50] PM2.5 can help adjust building's energy consumption
    Gao, Jingxin
    Duan, Changzan
    Song, Jinbo
    Ma, Liangdong
    Cai, Weiguang
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2023, 331