High precision measurement and error analysis on the moment of inertia for projectile

被引:0
|
作者
Zhu, YP [1 ]
Xu, XQ [1 ]
Zhang, MM [1 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Mech Engn, Nanjing 210094, Peoples R China
来源
ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings | 2005年
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The method of twist-swing is usually adopted to test the moment of. inertia for projectile. The test can be completed by measuring the period of a twist-swing system. In this paper, a swing-inertia-moment testing system is introduced, with simple structure and convenient installation and maintenance. The two-order liner vibration model is used in this measuring system to study the influence of the different loaded mass on the damping ratio. The possible maximum error and method to calculate the measuring range of the system can be confirmed on condition that the error requirement is defined. The method for selecting standard sample, which is used to calibrate the measurement system, is also given in this paper.
引用
收藏
页码:2454 / 2457
页数:4
相关论文
共 50 条
  • [22] Towards a high-precision measurement of the antiproton magnetic moment
    Smorra, C.
    Blaum, K.
    Franke, K.
    Matsuda, Y.
    Mooser, A.
    Nagahama, H.
    Ospelkaus, C.
    Quint, W.
    Schneider, G.
    Van Gorp, S.
    Walz, J.
    Yamazaki, Y.
    Ulmer, S.
    HYPERFINE INTERACTIONS, 2014, 228 (1-3): : 31 - 36
  • [23] Direct high-precision measurement of the magnetic moment of the proton
    A. Mooser
    S. Ulmer
    K. Blaum
    K. Franke
    H. Kracke
    C. Leiteritz
    W. Quint
    C. C. Rodegheri
    C. Smorra
    J. Walz
    Nature, 2014, 509 : 596 - 599
  • [24] Direct high-precision measurement of the magnetic moment of the proton
    Mooser, A.
    Ulmer, S.
    Blaum, K.
    Franke, K.
    Kracke, H.
    Leiteritz, C.
    Quint, W.
    Rodegheri, C. C.
    Smorra, C.
    Walz, J.
    NATURE, 2014, 509 (7502) : 596 - 599
  • [25] Towards a high-precision measurement of the antiproton magnetic moment
    C. Smorra
    K. Blaum
    K. Franke
    Y. Matsuda
    A. Mooser
    H. Nagahama
    C. Ospelkaus
    W. Quint
    G. Schneider
    S. Van Gorp
    J. Walz
    Y. Yamazaki
    S. Ulmer
    Hyperfine Interactions, 2014, 228 : 31 - 36
  • [26] Precision measurement of the Ω- magnetic moment
    Wallace, N.B.
    Border, P.M.
    Ciampa, D.P.
    Guglielmo, G.
    Heller, K.J.
    Woods, D.M.
    Johns, K.A.
    Gao, Y.T.
    Physical Review Letters, 1995, 74 (19):
  • [27] Measurement of Moment of Inertia Based on Hilbert Transform
    赵岩
    张晓琳
    王军
    唐文彦
    Transactions of Tianjin University, 2013, (03) : 225 - 230
  • [28] Measurement of moment of inertia based on Hilbert transform
    Zhao Y.
    Zhang X.
    Wang J.
    Tang W.
    Transactions of Tianjin University, 2013, 19 (3) : 225 - 230
  • [29] Design of a battery group high-precision measurement system based on error analysis
    Xu, Guojin
    Wu, Jian
    Wen, Jiapeng
    Bao, Yan
    Huang, Qinhe
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2013, 34 (09): : 1989 - 1997
  • [30] Measurement of Moment of Inertia Based on Hilbert Transform
    赵岩
    张晓琳
    王军
    唐文彦