Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences

被引:22
|
作者
Kyriazi, Stavroula [1 ,2 ,3 ]
Blackledge, Matthew [1 ,2 ,3 ]
Collins, David J. [1 ,2 ,3 ]
deSouza, Nandita M. [1 ,2 ,3 ]
机构
[1] Royal Marsden NHS Fdn Trust, CR UK, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Fdn Trust, EPSRC Canc Imaging Ctr, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Sutton SM2 5PT, Surrey, England
关键词
Diffusion-weighted imaging DWI; Image quality; Artefact; Eddy currents; Distortion; EDDY-CURRENT ARTIFACTS; COEFFICIENT MEASUREMENTS; MRI; REDUCTION; GRADIENT;
D O I
10.1007/s00330-010-1826-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare geometric distortion, signal-to-noise ratio (SNR), apparent diffusion coefficient (ADC), efficacy of fat suppression and presence of artefact between monopolar (Stejskal and Tanner) and bipolar (twice-refocused, eddy-current-compensating) diffusion-weighted imaging (DWI) sequences in the abdomen and pelvis. A semiquantitative distortion index (DI) was derived from the subtraction images with b = 0 and 1,000 s/mm(2) in a phantom and compared between the two sequences. Seven subjects were imaged with both sequences using four b values (0, 600, 900 and 1,050 s/mm(2)) and SNR, ADC for different organs and fat-to-muscle signal ratio (FMR) were compared. Image quality was evaluated by two radiologists on a 5-point scale. DI was improved in the bipolar sequence, indicating less geometric distortion. SNR was significantly lower for all tissues and b values in the bipolar images compared with the monopolar (p < 0.05), whereas FMR was not statistically different. ADC in liver, kidney and sacrum was higher in the bipolar scheme compared to the monopolar (p < 0.03), whereas in muscle it was lower (p = 0.018). Image quality scores were higher for the bipolar sequence (p a parts per thousand currency signaEuro parts per thousand 0.025). Artefact reduction makes the bipolar DWI sequence preferable in abdominopelvic applications, although the trade-off in SNR may compromise ADC measurements in muscle.
引用
收藏
页码:2422 / 2431
页数:10
相关论文
共 50 条
  • [31] Diffusion-weighted imaging of the spinal cord: Interleaved echo-planar imaging is superior to fast spin-echo
    Bammer, R
    Augustin, M
    Prokesch, RW
    Stollberger, R
    Fazekas, F
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) : 364 - 373
  • [32] Assessment of Mediastinal Tumors With Diffusion-Weighted Single-Shot Echo-Planar MRI
    Razek, Ahmed Abdel
    Elmorsy, Ahmed
    Elshafey, Mohsen
    Elhadedy, Tamer
    Hamza, Osama
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 535 - 540
  • [33] Diffusion tensor imaging focusing on lower cervical spinal cord using 2D reduced FOV interleaved multislice single-shot diffusion-weighted echo-planar imaging: comparison with conventional single-shot diffusion-weighted echo-planar imaging
    Park, Eun Hae
    Lee, Young Han
    Jeong, Eun-Kee
    Roh, Yun Ho
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2015, 33 (04) : 401 - 406
  • [34] Diffusion-weighted imaging of the sellar region: A comparison study of BLADE and single-shot echo planar imaging sequences
    Lu Yiping
    Liu Hui
    Zhou Kun
    Geng Daoying
    Yin Bo
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (07) : 1239 - 1244
  • [35] Comparison between turbo spin-echo and echo planar diffusion-weighted imaging of the female pelvis with 3T MRI
    Yoshizako, Takeshi
    Yoshida, Rika
    Asou, Hiroya
    Nakamura, Megumi
    Kitagaki, Hajime
    ACTA RADIOLOGICA OPEN, 2021, 10 (02)
  • [36] Diffusion-weighted single-shot echo-planar imaging with parallel technique in assessment of endometrial cancer
    Shen, Shu-Huei
    Chiou, Yi-You
    Wang, Jia-Hwia
    Yen, Ming-Shyen
    Lee, Rheun-Chuan
    Lai, Chiung-Ru
    Chang, Cheng-Yen
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (02) : 481 - 488
  • [37] Partial k-space reconstruction in single-shot diffusion-weighted echo-planar imaging
    Storey, Pippa
    Frigo, Fred J.
    Hinks, R. Scott
    Mock, Bryan J.
    Collick, Bruce D.
    Baker, Nicole
    Marmurek, Jonathan
    Graham, Simon J.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (03) : 614 - 619
  • [38] A tractography comparison between turboprop and spin-echo echo-planar diffusion tensor imaging
    Gui, Minzhi
    Peng, Huiling
    Carew, John D.
    Lesniak, Maciej S.
    Arfanakis, Konstantinos
    NEUROIMAGE, 2008, 42 (04) : 1451 - 1462
  • [39] Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla
    Xie, Simin
    Masokano, Ismail Bilal
    Liu, Wenguang
    Long, Xueying
    Li, Guijin
    Pei, Yigang
    Li, Wenzheng
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [40] Image quality evaluation of diffusion-weighted imaging in bladder cancer: a comparison between integrated slice-specific dynamic shimming and single-shot echo-planar imaging
    Wang, Yiqian
    Chen, Shaobin
    Zhang, Wei
    Xiao, Weixiong
    Su, Jiawei
    Zhang, Ruochen
    Wei, Yongbao
    Luo, Min
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (04) : 2526 - +