Determination of procaine hydrochloride using flow injection inhibitory chemiluminescence

被引:18
|
作者
Li, NB [1 ]
Chi, YW [1 ]
Wang, J [1 ]
Duan, JP [1 ]
Chen, GN [1 ]
机构
[1] Fuzhou Univ, Dept Chem, Fuzhou 350002, Peoples R China
关键词
procame hydrochloride; flow injection; inhibitory chemiluminescence;
D O I
10.1002/bio.713
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flow injection chemiluminescent method has been developed for the determination of procaine hydrochloride, based on the inhibition of the chemiluminescence reaction of luminol-hydrogen peroxide by procaine hydrochloride. The influence of several surfactants and beta-cyclodextrin on the chemiluminescence intensity were studied. It was found that beta-cyclodextrin enhanced the decrease in chemiluminescence intensity. The method is simple, convenient and sensitive, with a detection limit (3 sigma) of 0.08 mug/mL. The decreased chemiluminescence intensity is linear, with the concentration of procaine hydrochloride in the range 0.2-100.0 mug/mL and 100.0-400.0 mug/mL. The relative standard deviation for 10 repeated measurements were 4.5% and 3.4% for 1.0 and 20.0 mug/mL procaine hydrochloride, respectively. The method has been successfully applied to the determination of procaine hydrochloride in injection solutions of this drug. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:125 / 130
页数:6
相关论文
共 50 条
  • [42] Determination of diquat by flow injection–chemiluminescence
    J. L. López-Paz
    M. Catalá-Icardo
    B. Antón-Garrido
    Analytical and Bioanalytical Chemistry, 2009, 394 : 1073 - 1079
  • [43] Sensitive determination of ketoprofen using flow injection with chemiluminescence detection
    Zhuang, Yafeng
    Song, Hengli
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (03) : 824 - 828
  • [44] Determination of Mancozeb and Maneb using flow injection chemiluminescence detection
    Asghar, Muhammad
    Yaqoob, Mohammad
    Munawar, Nusrat
    Nabi, Abdul
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (11) : 2586 - 2606
  • [45] Determination of trivalent europium using flow injection chemiluminescence method
    Chen, SL
    Zhao, HC
    Wang, XL
    Li, X
    Jin, LP
    ANALYTICA CHIMICA ACTA, 2004, 506 (01) : 25 - 29
  • [46] Ultrasensitive determination of amoxicillin using chemiluminescence with flow injection analysis
    Xie, XF
    Song, ZH
    SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 2006, 20 (01): : 37 - 43
  • [47] Determination of ofloxacin using a chemiluminescence flow-injection method
    Rao, Y
    Tong, Y
    Zhang, XR
    Luo, G
    Baeyens, WRG
    ANALYTICA CHIMICA ACTA, 2000, 416 (02) : 227 - 230
  • [48] Spectral study and determination of metoclopramide and procaine hydrochloride by sequential injection analysis
    Wang, AJ
    Fan, J
    Feng, SF
    Cui, FL
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (03) : 432 - 435
  • [49] Determination of tetracycline, chlortetracycline and oxytetracycline by flow injection with inhibitory chemiluminescence detection using copper(II) as a probe ion
    Han, SQ
    Liu, EB
    Li, H
    LUMINESCENCE, 2006, 21 (02) : 106 - 111
  • [50] STOPPED-FLOW DETERMINATION OF PROCAINE HYDROCHLORIDE IN PHARMACEUTICAL PREPARATIONS
    GUTIERREZ, MC
    GOMEZHENS, A
    PEREZBENDITO, D
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (04) : 413 - 419