Multiplexed readout of high energy resolution γ-ray calorimeters

被引:0
|
作者
Miyazaki, T
Ullom, JN
Cunningham, MF
Labov, SE
机构
[1] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA
[2] NIST, Boulder, CO 80305 USA
关键词
microcalorimeter; transition-edge sensor; multiplex readout; frequency domain;
D O I
10.1016/S0921-4526(02)02430-4
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
We present the multiplexed readout of two gamma-ray microcalorimeters made from transition-edge sensors. We use a frequency-domain multiplexing scheme in which each sensor is biased at an identifying frequency. We obtain an energy resolution of about 60 eV at 60 keV for each sensor. (C) 2003 Published by Elsevier Science B.V.
引用
收藏
页码:1623 / 1624
页数:2
相关论文
共 50 条
  • [21] Search for new scintillators for high-energy resolution electromagnetic calorimeters
    Britvich, G.I.
    Britvich, I.G.
    Vasil'chenko, V.G.
    Lishin, V.A.
    Obraztsov, V.F.
    Polyakov, V.A.
    Solovjev, A.S.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 426 (02): : 453 - 463
  • [22] High resolution x-ray detection using metallic magnetic calorimeters
    Fleischmann, A
    ADVANCES IN SOLID STATE PHYSICS 41, 2001, 41 : 577 - 588
  • [23] Multiplexed high resolution soft x-ray RIXS
    Chuang, Y-D
    Anderson, C.
    Benk, M.
    Goldberg, K.
    Voronov, D.
    Warwick, T.
    Yashchuk, V.
    Padmore, H. A.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [24] MONTE-CARLO STUDY OF THE LIGHT YIELD, UNIFORMITY AND ENERGY RESOLUTION OF ELECTROMAGNETIC CALORIMETERS WITH A FIBER READOUT SYSTEM
    LABARGA, L
    ROS, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 249 (2-3): : 228 - 234
  • [25] CZT detectors as MeV gamma-ray calorimeters with excellent position and energy resolution
    Jung, I
    Perkins, J
    Krawczynski, H
    Sobotka, L
    Komarov, S
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4383 - 4387
  • [26] ON THE ENERGY RESOLUTION OF URANIUM AND OTHER HADRON CALORIMETERS
    WIGMANS, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 259 (03): : 389 - 429
  • [27] Towards Energy-Dispersive Particle Detection with sub-eV Energy Resolution: Metallic Magnetic Calorimeters with Direct Sensor Readout
    Krantz, Matthaus
    Fleischmann, Andreas
    Enss, Christian
    Kempf, Sebastian
    2019 IEEE INTERNATIONAL SUPERCONDUCTIVE ELECTRONICS CONFERENCE (ISEC), 2019,
  • [28] Performance of High-Resolution, Micro-fabricated, X-ray Magnetic Calorimeters
    Bandler, Simon R.
    Adams, Joseph S.
    Beyer, Joern
    Hsieh, Wen-Ting
    Kelley, Richard L.
    Kilbourne, Caroline A.
    Porst, Jan-Patrick
    Porter, F. Scott
    Rotzinger, Hannes
    Seidel, George M.
    Smith, Stephen J.
    Stevenson, Thomas R.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 579 - +
  • [29] Metallic magnetic calorimeters (MMC): detectors for high-resolution X-ray spectroscopy
    Fleischmann, A
    Link, M
    Daniyarov, T
    Rotzinger, H
    Enss, C
    Seidel, GM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 27 - 31
  • [30] THE E/H RATIO AND ENERGY RESOLUTION OF HADRON CALORIMETERS
    FESEFELDT, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 263 (01): : 114 - 135