The accuracy of digital templating in cementless total hip arthroplasty in dysplastic hips

被引:6
|
作者
Kristoffersson, Emelie [1 ]
Otten, Volker [1 ]
Crnalic, Sead [1 ]
机构
[1] Umea Univ, Dept Surg & Perioperat Sci Orthopaed, S-90185 Umea, Sweden
关键词
Digital templating; Dysplasia; Cementless total hip arthroplasty; Accuracy; DEVELOPMENTAL DYSPLASIA; REPLACEMENT; JOINT;
D O I
10.1186/s12891-021-04793-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) is a complex procedure due to associated anatomical abnormalities. We studied the extent to which preoperative digital templating is reliable when performing cementless THA in patients with DDH. Methods We templated and compared the pre- and postoperative sizes of the acetabular and femoral components and the center of rotation (COR), and analysed the postoperative cup coverage, leg length discrepancy (LLD), and stem alignment in 50 patients (56 hips) with DDH treated with THA. Results The implant size exactly matched the template size in 42.9% of cases for the acetabular component and in 38.2% of cases for the femoral component, whereas the templated +/- 1 size was used in 80.4 and 81.8% of cases for the acetabular and femoral components, respectively. There were no statistically significant differences between templated and used component sizes among different DDH severity levels (acetabular cup: p = 0.30 under the Crowe classification and p = 0.94 under the Hartofilakidis classification; femoral stem: p = 0.98 and p = 0.74, respectively). There were no statistically significant differences between the planned and postoperative COR (p = 0.14 horizontally and p = 0.52 vertically). The median postoperative LLD was 7 (range 0-37) mm. Conclusion Digital preoperative templating is reliable in the planning of cementless THA in patients with DDH.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Outcomes in 385 developmental dysplastic hips requiring total hip arthroplasty
    Seo, Lauren J.
    Gabor, Jonathan
    Novikov, David
    Feng, James E.
    Schwarzkopf, Ran
    Vigdorchik, Jonathan M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (05) : 723 - 728
  • [22] Outcomes in 385 developmental dysplastic hips requiring total hip arthroplasty
    Lauren J. Seo
    Jonathan Gabor
    David Novikov
    James E. Feng
    Ran Schwarzkopf
    Jonathan M. Vigdorchik
    Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 723 - 728
  • [23] Acetate templating on calibrated standing digital radiograph improves accuracy of preoperative templating for total hip arthroplasty
    Wang, Q.
    Xiao, J.
    Zhu, L.
    Zhao, X.
    Liu, Z.
    Wang, J.
    Qin, Y.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (03) : 341 - 347
  • [24] CEMENTLESS TOTAL REPLACEMENT FOR SEVERELY DYSPLASTIC OR DISLOCATED HIPS
    PAAVILAINEN, T
    HOIKKA, V
    SOLONEN, KA
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (02): : 205 - 211
  • [25] Effect of Training Level on Accuracy of Digital Templating in Primary Total Hip and Knee Arthroplasty
    Hsu, Andrew R.
    Kim, Jeffrey D.
    Bhatia, Sanjeev
    Levine, Brett R.
    ORTHOPEDICS, 2012, 35 (02) : E179 - E183
  • [26] Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs
    Oddy, MJ
    Jones, MJ
    Pendegrass, CJ
    Pilling, JR
    Wimhurst, JA
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (05): : 581 - 585
  • [27] Digital templating in total hip arthroplasty with the Mayo stem
    Wedemeyer, Christian
    Quitmann, Henning
    Xu, Jie
    Heep, Hansjoerg
    von Knoch, Marius
    Saxler, Guido
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (10) : 1023 - 1029
  • [28] Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study
    D. Dammerer
    A. Keiler
    S. Herrnegger
    D. Putzer
    S. Strasser
    M. Liebensteiner
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 2471 - 2480
  • [29] Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study
    Dammerer, D.
    Keiler, A.
    Herrnegger, S.
    Putzer, D.
    Strasser, S.
    Liebensteiner, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (10) : 2471 - 2480
  • [30] Precision of preoperative digital templating in total hip arthroplasty
    Efe, Turgay
    El Zayat, Bilal Farouk
    Heyse, Thomas J.
    Timmesfeld, Nina
    Fuchs-Winkelmann, Susanne
    Schmitt, Jan
    ACTA ORTHOPAEDICA BELGICA, 2011, 77 (05): : 616 - 621