Image quality improvements with time-of-flight positron emission tomography for molecular imaging

被引:0
|
作者
Manjeshwar, RM [1 ]
Shao, YP [1 ]
Jansen, FP [1 ]
机构
[1] GE Co, Global Res Ctr, Niskayuna, NY 12309 USA
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The renewed interest in Time Of Flight (TOF) PET is being driven by the development of detector technology and the growth of new molecular imaging applications. In this study we performed Monte Carlo simulations to quantify image quality improvements as a function of timing resolution for imaging scenarios that mimic whole body and brain imaging. We implemented an iterative image reconstruction algorithm that incorporated time-of-flight information. Image quality, as measured through contrast and noise metrics, consistently improved with improved timing resolution. We simulated and compared a conventional PET scanner with a TOF-PET scanner with 200 ps timing resolution. For lesions embedded in 40cm and 20 cm cylindrical objects, lesion contrast improved by a factor of 3.4 and 2.3, respectively. TOF-PET holds the potential for significantly improved imaging over conventional PET scanners of equivalent sensitivity.
引用
收藏
页码:853 / 856
页数:4
相关论文
共 50 条
  • [31] Poisson-noise weighted filter for time-of-flight positron emission tomography
    Zeng, Gengsheng L.
    Lv, Li
    Huang, Qiu
    VISUAL COMPUTING FOR INDUSTRY BIOMEDICINE AND ART, 2020, 3 (01)
  • [32] HRFlexToT: A High Dynamic Range ASIC for Time-of-Flight Positron Emission Tomography
    Sanchez, David
    Gomez, Sergio
    Mauricio, Joan
    Freixas, Lluis
    Sanuy, Andreu
    Guixe, Gerard
    Lopez, Albert
    Manera, Rafel
    Marin, Jesus
    Perez, Jose M.
    Picatoste, Eduardo
    Pujol, Carolina
    Sanmukh, Anand
    Rato, Pedro
    Vela, Oscar
    Gascon, David
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (01) : 51 - 67
  • [33] Pilot study of timing performance for time-of-flight positron emission tomography detector
    Liu, Jun-Hui
    Li, Dao-Wu
    Zhang, Zhi-Ming
    Liao, Yan-Fei
    Huang, Xian-Chao
    Wang, Pei-Lin
    Chen, Yan
    Yun, Ming-Kai
    Feng, Bao-Tong
    Shuai, Lei
    Wang, Bao-Yi
    Zhang, Tian-Bao
    Wei, Long
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2011, 45 (12): : 1522 - 1526
  • [34] TIME-OF-FLIGHT POSITRON-EMISSION TOMOGRAPHY STATUS RELATIVE TO CONVENTIONAL PET
    TERPOGOSSIAN, MM
    FICKE, DC
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (01) : 136 - 137
  • [35] Sensitivity estimation in time-of-flight list-mode positron emission tomography
    Herraiz, J. L.
    Sitek, A.
    MEDICAL PHYSICS, 2015, 42 (11) : 6690 - 6702
  • [36] Enhanced positronium lifetime imaging through two-component reconstruction in time-of-flight positron emission tomography
    Chen, Zhuo
    Kao, Chien-Min
    Huang, Hsiun-Hsiung
    An, Lingling
    FRONTIERS IN PHYSICS, 2024, 12
  • [37] A New Direction to Explore to Advance Coincidence Time Resolution for Time-of-Flight Positron Emission Tomography
    Tao, L.
    Levin, C. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S305 - S306
  • [38] Promising Detector Concepts to Advance Coincidence Time Resolution for Time-of-Flight Positron Emission Tomography
    Levin, C. S.
    ACTA PHYSICA POLONICA A, 2022, 142 (03) : 422 - 427
  • [39] EFFECT OF THE SOFTWARE COINCIDENCE TIMING WINDOW IN TIME-OF-FLIGHT ASSISTED POSITRON EMISSION TOMOGRAPHY
    YAMAMOTO, M
    FICKE, DC
    TERPOGOSSIAN, MM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (01) : 711 - 714
  • [40] Analytic time-of-flight positron emission tomography reconstruction: three-dimensional case
    Gengsheng L. Zeng
    Ya Li
    Qiu Huang
    Visual Computing for Industry, Biomedicine, and Art, 3