The renewed interest in Time Of Flight (TOF) PET is being driven by the development of detector technology and the growth of new molecular imaging applications. In this study we performed Monte Carlo simulations to quantify image quality improvements as a function of timing resolution for imaging scenarios that mimic whole body and brain imaging. We implemented an iterative image reconstruction algorithm that incorporated time-of-flight information. Image quality, as measured through contrast and noise metrics, consistently improved with improved timing resolution. We simulated and compared a conventional PET scanner with a TOF-PET scanner with 200 ps timing resolution. For lesions embedded in 40cm and 20 cm cylindrical objects, lesion contrast improved by a factor of 3.4 and 2.3, respectively. TOF-PET holds the potential for significantly improved imaging over conventional PET scanners of equivalent sensitivity.
引用
收藏
页码:853 / 856
页数:4
相关论文
共 50 条
  • [1] Windowed image reconstruction for time-of-flight positron emission tomography
    Kao, Chien-Min
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (13): : 3431 - 3445
  • [2] Instrumentation for Time-of-Flight Positron Emission Tomography
    Ullah M.N.
    Pratiwi E.
    Cheon J.
    Choi H.
    Yeom J.Y.
    Nuclear Medicine and Molecular Imaging, 2016, 50 (2) : 112 - 122
  • [3] Relationship between the image quality and noise-equivalent count in time-of-flight positron emission tomography
    Akira Maebatake
    Go Akamatsu
    Kenta Miwa
    Yuji Tsutsui
    Kazuhiko Himuro
    Shingo Baba
    Masayuki Sasaki
    Annals of Nuclear Medicine, 2016, 30 : 68 - 74
  • [4] Relationship between the image quality and noise-equivalent count in time-of-flight positron emission tomography
    Maebatake, Akira
    Akamatsu, Go
    Miwa, Kenta
    Tsutsui, Yuji
    Himuro, Kazuhiko
    Baba, Shingo
    Sasaki, Masayuki
    ANNALS OF NUCLEAR MEDICINE, 2016, 30 (01) : 68 - 74
  • [5] TIME-OF-FLIGHT POSITRON EMISSION TOMOGRAPHY WITH RADIOFREQUENCY PHOTOTUBE
    Margaryan, Amur
    Kakoyan, Vanik
    Knyazyan, Svetlana
    WORKSHOP ON TIMING DETECTORS: ELECTRONICS, MEDICAL AND PARTICLE PHYSICS APPLICATIONS, 2010, 4 (01): : 107 - 112
  • [6] FEASIBILITY OF TIME-OF-FLIGHT RECONSTRUCTION IN POSITRON EMISSION TOMOGRAPHY
    MULLANI, NA
    MARKHAM, J
    TERPOGOSSIAN, MM
    JOURNAL OF NUCLEAR MEDICINE, 1980, 21 (11) : 1095 - 1097
  • [7] REAL-TIME IMAGE-RECONSTRUCTION FOR TIME-OF-FLIGHT POSITRON EMISSION TOMOGRAPHY (TOFPET)
    PHILIPPE, EA
    MULLANI, N
    WONG, W
    HARTZ, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) : 524 - 528
  • [8] High-resolution image reconstruction method for time-of-flight positron emission tomography
    Yamaya, T
    Obi, T
    Yamaguchi, M
    Ohyama, N
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11): : 3125 - 3134
  • [9] IMAGE IMPROVEMENTS IN POSITRON-EMISSION TOMOGRAPHY DUE TO MEASURING DIFFERENTIAL TIME-OF-FLIGHT AND USING MAXIMUM-LIKELIHOOD-ESTIMATION
    POLITTE, DG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 737 - 742
  • [10] Characterization of time of flight and resolution modeling on image quality in positron emission tomography
    Moretti, Terrance J.
    Leon, Stephanie M.
    Schaeffer, Colin J.
    Arreola, Manuel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (10):