Development of an Automated Tracer Testing System for UASB Laboratory-Scale Reactors

被引:1
|
作者
Cisneros, Juan F. [1 ,2 ,3 ,4 ]
Pelaez-Samaniego, Manuel Raul [1 ,4 ]
Pinos, Veronica [2 ,4 ]
Nopens, Ingmar [5 ]
Alvarado, Andres [2 ,6 ]
机构
[1] Univ Cuenca, Dept Quim Aplicada & Sistemas Prod, Cuenca 010203, Ecuador
[2] Univ Cuenca, Dept Recursos Hidr & Ciencias Ambientales, Cuenca 010203, Ecuador
[3] Univ Cuenca, PROMAS, Cuenca 010203, Ecuador
[4] Univ Cuenca, Fac Ciencias Quim, Cuenca 010203, Ecuador
[5] Univ Ghent, Dept Data Anal & Math Modelling, BIOMATH, B-9000 Ghent, Belgium
[6] Univ Cuenca, Fac Ingn, Cuenca 010203, Ecuador
关键词
automated system; laboratory-scale model reactor; UASB reactor; residence time distribution curve; WATER-TREATMENT; HYDRAULICS; FLOW;
D O I
10.3390/w13131821
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Residence time distribution (RTD) curves play an essential role in the hydraulic characterization of reactors. Current approaches for obtaining RTD curves in laboratory-scale reactors are time-consuming and subject to large errors. Thus, automated systems to obtain RTD curves in laboratory-scale reactors are of great interest for reducing experimental errors due to human interaction, minimizing experimentation costs, and continuously obtaining experimental data. An automated system for obtaining RTD curves in laboratory-scale reactors was designed, built, and tested in this work. During the tests conducted in a cylindrical upflow anaerobic sludge blanket (UASB) reactor, the system worked properly using the stimulus-response pulse technique with sodium chloride as a tracer. Four main factors were found to affect the representativeness of the RTD curves: flow stabilization time, test water conductivity, temperature, and surface tension. A discussion on these factors and the corresponding solutions is presented. The RTD curves of the UASB reactor are left-skewed with a typical tank reactor's flow shape with channeling and dead zones. A transitory flow behavior was evidenced in the reactor, which indicates the influence of internal turbulent flow structures. The system proposed herein is expected to help study the hydraulics of reactors using laboratory-scale models more efficiently.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Effect of environmental parameters on the degradability of polymer films in laboratory-scale composting reactors
    Gu, Ji-Dong
    Yang, Shunjuan
    Welton, R.
    Eberiel, D.
    McCarthy, S.P.
    Gross, R.A.
    Journal of Environmental Polymer Degradation, 1994, 2 (02): : 129 - 135
  • [32] LABORATORY-SCALE PLANT FOR SEED GERMINATION AND PLANT DEVELOPMENT
    Sukhanov, Yuri V.
    Vasilev, Aleksey S.
    Kozyr, Artur S.
    Kempi, Elena A.
    AD ALTA-JOURNAL OF INTERDISCIPLINARY RESEARCH, 2022, 12 (02): : 302 - 306
  • [33] Hydraulics of laboratory and full-scale upflow anaerobic sludge blanket (UASB) reactors
    Batstone, DJ
    Hernandez, JLA
    Schmidt, JE
    BIOTECHNOLOGY AND BIOENGINEERING, 2005, 91 (03) : 387 - 391
  • [34] Fouling mechanisms in a laboratory-scale UV disinfection system
    Nessim, Yoel
    Gehr, Ronald
    WATER ENVIRONMENT RESEARCH, 2006, 78 (12) : 2311 - 2323
  • [35] BALING SYSTEM FOR MAKING LABORATORY-SCALE HAY BALES
    COBLENTZ, WK
    FRITZ, JO
    BOLSEN, KK
    AGRONOMY JOURNAL, 1993, 85 (04) : 962 - 965
  • [36] Pharmaceutical process development applying automated laboratory reactors
    Chovan, Tibor
    Markovits, Imre
    Farkas, Bela
    Nagy, Kalman
    Nagy, Lajos
    Nyiri, Karoly
    Szeifert, Ferenc
    16TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING AND 9TH INTERNATIONAL SYMPOSIUM ON PROCESS SYSTEMS ENGINEERING, 2006, 21 : 1089 - 1094
  • [37] Laboratory-scale testing of titanium powder fire extinguishment using water
    Kostka, Stanislav
    FIRE SAFETY JOURNAL, 2023, 141
  • [38] Biodegradation of a simulated textile effluent by immobilised-coated laccase in laboratory-scale reactors
    Osma, Johann F.
    Toca-Herrera, Jose L.
    Rodriguez-Couto, Susana
    APPLIED CATALYSIS A-GENERAL, 2010, 373 (1-2) : 147 - 153
  • [39] LABORATORY-SCALE UASB DIGESTERS (WITH/WITHOUT CONDITIONING TANK AND RECYCLE) - EFFICACY TO TREAT INCREASED HYDRAULIC LOADS
    DUDLEY, BT
    HOWGRAVEGRAHAM, AR
    ISHERWOOD, H
    SENIOR, E
    WATER SA, 1993, 19 (04) : 313 - 318
  • [40] DESIGN MODIFICATION AND TESTING OF A LABORATORY-SCALE SWEET SORGHUM STALK PRESS
    Cosgrove, C. T.
    Huhnke, R. L.
    Bellmer, D. D.
    APPLIED ENGINEERING IN AGRICULTURE, 2012, 28 (01) : 99 - 104