Iatrogenic facial nerve exposure in cochlear implant surgery: incidence and clinical significance in the absence of intra-operative nerve monitoring

被引:9
|
作者
Mandour, Mahmoud F. [1 ]
Khalifa, Mohammed Adel [1 ]
Khalifa, Hossam M. Adel [1 ]
Amer, Mohammed Abdel Rahman [2 ]
机构
[1] Tanta Univ, Dept Otolaryngol Head & Neck Surg, Tanta, Egypt
[2] Tanta Univ, Dept ORL HNS, Tanta, Egypt
关键词
Cochlear Implant; Facial Palsy; Facial Paralysis; Facial Nerve Monitoring; COMPLICATIONS; MANAGEMENT;
D O I
10.1080/14670100.2019.1625126
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: Iatrogenic facial nerve injury is one of the most feared complications of cochlear implantation. Intraoperative facial nerve monitoring is used as an adjunctive modality in a variety of neurotologic surgeries including cochlear implantation. With the lack of nerve monitoring, there is a theoretically higher risk of iatrogenic fallopian canal dehiscence with facial nerve exposure, particularly the mastoid portion, during cochlear implant surgery. The purpose of this study is to determine the incidence of iatrogenic exposure of the facial nerve and its relation to the incidence of post-operative facial paralysis in the absence of facial nerve monitoring. Methods: This was a retrospective study. Medical charts of 307 patients who underwent cochlear implantation without facial nerve monitoring, from 2012 to 2017 were reviewed to identify cases with a reported iatrogenic defect over the mastoid facial nerve. The incidence of post-operative facial palsy was determined and compared to the incidence with the use of intra-operative monitoring which has been reported in the literature. Results: The incidence of iatrogenic dehiscence with facial nerve exposure was 46.58%. However, the incidence of post-operative facial palsy was only 2.1% which decreased to 0.72% in cases without injury of the facial neural sheath. This was not significantly different from the 0.73% rate reported in the literature with the use of intra-operative facial monitoring (P = 0.99). Conclusion: The incidence of iatrogenic facial nerve exposure during cochlear implantation may be relatively high. However, no additional risk of post-operative facial nerve paralysis was found, provided that the integrity of the neural sheath was preserved, even with the lack of intra-operative monitoring.
引用
收藏
页码:250 / 254
页数:5
相关论文
共 50 条
  • [21] Iatrogenic Facial Nerve Injury in Head and Neck Surgery in the Presence of Intraoperative Facial Nerve Monitoring With Electromyography: A Systematic Review
    Dogiparthi, Jaswanthi
    Teru, Smaran S.
    Lomiguen, Christine M.
    Chin, Justin
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [22] Intra-operative neuromonitoring of the laryngeal nerve in thyroid surgery:: mandatory or nice to have?
    Staerkle, R. F.
    Fahrner, H. B.
    Furrer, M.
    BRITISH JOURNAL OF SURGERY, 2006, 93 (09) : 1163 - 1163
  • [23] Respiratory Variation Predicts Optimal Endotracheal Tube Placement for Intra-operative Nerve Monitoring in Thyroid and Parathyroid Surgery
    Kyle J. Chambers
    Allison Pearse
    Jonathan Coveney
    Sarah Rogers
    Dipti Kamani
    Niranjan Sritharan
    Gregory W. Randolph
    World Journal of Surgery, 2015, 39 : 393 - 399
  • [24] Respiratory Variation Predicts Optimal Endotracheal Tube Placement for Intra-operative Nerve Monitoring in Thyroid and Parathyroid Surgery
    Chambers, Kyle J.
    Pearse, Allison
    Coveney, Jonathan
    Rogers, Sarah
    Kamani, Dipti
    Sritharan, Niranjan
    Randolph, Gregory W.
    WORLD JOURNAL OF SURGERY, 2015, 39 (02) : 393 - 399
  • [25] Minimizing shoulder syndrome with intra-operative spinal accessory nerve monitoring for neck dissection
    Lee, C. -H.
    Huang, N. -C.
    Chen, H. -C.
    Chen, M. -K.
    ACTA OTORHINOLARYNGOLOGICA ITALICA, 2013, 33 (02) : 93 - 96
  • [26] COMBINED EXTRADURAL-INTERDURAL-INTRADURAL APPROACH TO A TRIGEMINAL NERVE CYSTIC HAEMANGIOPERICYTOMA WITH INTRA-OPERATIVE CRANIAL NERVE MONITORING
    Frantzias, Joseph
    Lavrador, Jose
    Pereira, Noemia
    Gullan, Richard
    Ashkan, Keyoumars
    Vergani, Francesco
    Bhangoo, Ranjeev
    Thomas, Nick
    NEURO-ONCOLOGY, 2019, 21 : 18 - 18
  • [27] Automatic pre- to intra-operative CT registration for image-guided cochlear implant surgery
    Reda, Fitsum A.
    Dawant, Benoit M.
    Labadie, Robert F.
    Noble, Jack H.
    MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [28] Intra-operative identification of a temporal bone fracture line during cochlear implant surgery: a case report
    Gaelle Vofo
    Sagit Stern Shavit
    Ron Eliashar
    Michal Kaufmann
    BMC Pediatrics, 23
  • [29] Intra-operative identification of a temporal bone fracture line during cochlear implant surgery: a case report
    Vofo, Gaelle
    Shavit, Sagit Stern
    Eliashar, Ron
    Kaufmann, Michal
    BMC PEDIATRICS, 2023, 23 (01)
  • [30] Automatic Pre- to Intra-Operative CT Registration for Image-Guided Cochlear Implant Surgery
    Reda, Fitsum A.
    Noble, Jack H.
    Labadie, Robert F.
    Dawant, Benoit M.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (11) : 3070 - 3077