Liquid Maldistribution in Random Packed Columns: Experimental Investigation of Influencing Factors

被引:6
|
作者
Hanusch, Florian [1 ]
Rehfeldt, Sebastian [1 ]
Klein, Harald [1 ]
机构
[1] Tech Univ Munich, Lehrstuhl Anlagen & Prozesstech, Boltzmannstr 15, D-85748 Garching, Germany
关键词
Liquid Distribution; Maldistribution; Packed Columns; Random Packing; X-RAY TOMOGRAPHY; STRUCTURED PACKING; ABSORPTION COLUMNS; FLOW; EFFICIENCY; HOLDUP; BED; SEPARATION; DIAMETER; SCALE;
D O I
10.1002/cite.201700015
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Investigations on liquid maldistribution in random packings are conducted in a empty set1.2m packed column at varying experimental and operating parameters - type of packing, packing height, liquid distributor, liquid load, and gas load. Used types of packing are metal Raflux-Rings 35-5 and 50-5, RVT Metal Saddle Rings 70-5 and plastic Hiflow (R)-Rings 50-6. Graphical presentation in form of distribution spectra and further evaluation by means of a maldistribution factor provide insight into the influence of different parameters on maldistribution.
引用
收藏
页码:1550 / 1560
页数:11
相关论文
共 50 条
  • [41] Experimental Investigations of Foam in Packed Columns
    Senger, Gerrit
    Wozny, Guenter
    CHEMIE INGENIEUR TECHNIK, 2011, 83 (04) : 503 - 510
  • [42] Application of a wire-mesh sensor for the experimental characterization of liquid distribution in packed columns
    Brinkmann, Jost H.
    Plate, Dominik
    Merkel, Amelie
    Seithummer, Valentin Benedikt
    Biessey, Philip
    Grunewald, Marcus
    CHEMICAL ENGINEERING SCIENCE, 2021, 239
  • [43] PACKED CAPILLARY COLUMNS FOR LIQUID-CHROMATOGRAPHY
    HOFFMANN, S
    BLOMBERG, L
    CHROMATOGRAPHIA, 1987, 24 : 416 - 420
  • [44] Process intensification: Visual study of liquid maldistribution in rotating packed beds - Reply
    Burns, JR
    Ramshaw, C
    CHEMICAL ENGINEERING SCIENCE, 1997, 52 (03) : 455 - 455
  • [45] LIQUID HOLDUP AND DISPERSION IN PACKED-COLUMNS
    KUSHALKAR, KB
    PANGARKAR, VG
    CHEMICAL ENGINEERING SCIENCE, 1990, 45 (03) : 759 - 763
  • [47] LIQUID HOLDUP IN IRRIGATED PACKED-COLUMNS
    ELAMIN, IHM
    JOURNAL OF ENGINEERING SCIENCES, 1987, 13 (02): : 191 - 201
  • [48] INTERFACIAL AREA IN PACKED LIQUID EXTRACTION COLUMNS
    PRATT, HRC
    WHITE, AS
    CHEMISTRY & INDUSTRY, 1952, (16) : 358 - 359
  • [49] Research progress of liquid distributors in packed columns
    Li C.
    Han X.
    Liu J.
    Wang Y.
    Wang C.
    Wang H.
    Peng S.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2023, 42 (09): : 4479 - 4495
  • [50] Experimental investigation of liquid chromatography columns by means of computed tomography
    Dirk-Uwe Astrath
    Florian Lottes
    Duc Thoung Vu
    Wolfgang Arlt
    Erling H. Stenby
    Adsorption, 2007, 13 : 9 - 19