SENSITIVITY OF HEMODYNAMICS IN A PATIENT SPECIFIC CEREBRAL ANEURYSM TO VASCULAR GEOMETRY AND BLOOD RHEOLOGY

被引:50
|
作者
Gambaruto, Alberto M. [1 ,2 ]
Janela, Joao [3 ,4 ]
Moura, Alexandra [1 ,2 ]
Sequeira, Adelia [1 ,2 ]
机构
[1] Dept Math, P-1049001 Lisbon, Portugal
[2] CEMAT IST, P-1049001 Lisbon, Portugal
[3] Univ Tecn Lisboa, Dept Math ISEG, P-1200781 Lisbon, Portugal
[4] CEMAT IST, P-1200781 Lisbon, Portugal
关键词
Blood flow modeling; medical image reconstruction; non-Newtonian fluids; COMPUTATIONAL FLUID-DYNAMICS; INTRACRANIAL ANEURYSMS; PARENT VESSEL; FLOW; RUPTURE; ARTERY; MODELS; RISK; WALL;
D O I
10.3934/mbe.2011.8.409
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Newtonian and generalized Newtonian mathematical models for blood flow are compared in two different reconstructions of an anatomically realistic geometry of a saccular aneurysm, obtained from rotational CTA and differing to within image resolution. The sensitivity of the flow field is sought with respect to geometry reconstruction procedure and mathematical model choice in numerical simulations. Taking as example a patient specific intracranial aneurysm located on an outer bend under steady state simulations, it is found that the sensitivity to geometry variability is greater, but comparable, to the one of the rheological model. These sensitivities are not quantifiable a priori. The flow field exhibits a wide range of shear stresses and slow recirculation regions that emphasize the need for careful choice of constitutive models for the blood. On the other hand, the complex geometrical shape of the vessels is found to be sensitive to small scale perturbations within medical imaging resolution. The sensitivity to mathematical modeling and geometry definition are important when performing numerical simulations from in vivo data, and should be taken into account when discussing patient specific studies since differences in wall shear stress range from 3% to 18%.
引用
收藏
页码:409 / 423
页数:15
相关论文
共 50 条
  • [21] Biomechanical Simulation to Compare the Blood Hemodynamics and Cerebral Aneurysm Rupture Risk in Patients with Different Aneurysm Necks
    Hajirayat, K.
    Gholampour, S.
    Sharifi, I.
    Bizari, D.
    JOURNAL OF APPLIED MECHANICS AND TECHNICAL PHYSICS, 2017, 58 (06) : 968 - 974
  • [22] CEREBRAL BLOOD FLOW AND HEMODYNAMICS IN EXTRACRANIAL VASCULAR DISEASE - EFFECT OF ENDARTERECTOMY
    ADAMS, JE
    SMITH, MC
    WYLIE, EJ
    LEAKE, TB
    HALLIDAY, B
    SURGERY, 1963, 53 (04) : 449 - 455
  • [23] Coupled Simulation of Hemodynamics and Vascular Growth and Remodeling in a Subject-Specific Geometry
    Jiacheng Wu
    Shawn C. Shadden
    Annals of Biomedical Engineering, 2015, 43 : 1543 - 1554
  • [24] Coupled Simulation of Hemodynamics and Vascular Growth and Remodeling in a Subject-Specific Geometry
    Wu, Jiacheng
    Shadden, Shawn C.
    ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (07) : 1543 - 1554
  • [25] A Hybrid 1D and 3D Approach to Hemodynamics Modelling for a Patient-Specific Cerebral Vasculature and Aneurysm
    Ho, Harvey
    Sands, Gregory
    Schmid, Holger
    Mithraratne, Kumar
    Mallinson, Gordon
    Hunter, Peter
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT II, PROCEEDINGS, 2009, 5762 : 323 - +
  • [26] Efficient parallel simulation of hemodynamics in patient-specific abdominal aorta with aneurysm
    Qin, Shanlin
    Wu, Bokai
    Liu, Jia
    Shiu, Wen-Shin
    Yan, Zhengzheng
    Chen, Rongliang
    Cai, Xiao-Chuan
    Chen, Rongliang (rl.chen@siat.ac.cn); Cai, Xiao-Chuan (xccai@um.edu.mo), 1600, Elsevier Ltd (136):
  • [27] Patient-specific blood flows simulation on cerebral aneurysm based on physically consistency feedback control
    Adib, Mohd Azrul Hisham Mohd
    Ii, Satoshi
    Watanabe, Yoshiyuki
    Wada, Shigeo
    2016 IEEE 16TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2016, : 334 - 337
  • [28] Experimental Studies on the Contralateral Regulation of Cerebral Blood Flow Using a Patient-Specific Aneurysm Model
    Mu, Lizhong
    He, Ying
    Chen, Junyuan
    Yu, Xunjie
    Wei, Jianhui
    Ji, Changjin
    Lv, Jiaqi
    ADVANCES IN COGNITIVE NEURODYNAMICS (V), 2016, : 331 - 338
  • [29] Efficient parallel simulation of hemodynamics in patient-specific abdominal aorta with aneurysm
    Qin, Shanlin
    Wu, Bokai
    Liu, Jia
    Shiu, Wen-Shin
    Yan, Zhengzheng
    Chen, Rongliang
    Cai, Xiao-Chuan
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 136
  • [30] Towards patient-specific modeling - I. - Hemodynamics in a growing aneurysm
    Figueroa, C. Alberto
    Baek, Seungik
    Vignon-Clementel, Irene E.
    Humphrey, Jay D.
    Taylor, Charles A.