Knee Flexors Maximum Effective Angle Variation after Anterior Cruciate Ligament Reconstruction with Hamstring Graft

被引:0
|
作者
Fruytier, Hugues [1 ]
Mazeas, Jean P. T. [1 ,2 ]
Traulle, Maude [1 ,2 ]
Vandebrouck, Amaury [3 ]
Duffiet, Pascal [3 ]
Ratte, Louis [3 ]
Forelli, Florian [1 ,2 ,4 ]
机构
[1] Ramsay Sante, Clin Domont, OrthoLab, 85 Route Domont, F-95330 Domont, France
[2] OrthoSport Rehab Ctr, 16 Rue Paris, F-95330 Domont, France
[3] Clin Domont, 85 Route Domont, F-95330 Domont, France
[4] CDFAS, Med & Res Ctr High Sport Performance, 64 Rue Bouquinvilles, F-95600 Eauhonne, France
关键词
maximum effective angle; anterior cruciate ligament reconstruction; knee flexor; hamstring graft; variation; STRAIN INJURY; RISK-FACTORS; MUSCLES; STRENGTH;
D O I
10.15621/ijphy/2021/v8i2/999
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: During the anterior cruciate ligament reconstruction, the graft is taken from the distal hamstring tendon, which causes morphological and neurological changes in these muscles, particularly on the maximum effective angle of the knee flexors. The present study investigates changes in knee flexor following anterior cruciate ligament reconstruction with a hamstring graft. Methods: Two populations participated in this study, a healthy group and a group that underwent anterior cruciate ligament reconstruction with a hamstring graft. First, the test group underwent two postoperative assessments on an isokinetic device at 3 and 6 months. Next, we compared the test group at 3 and 6 months with the control group to highlight the differences between the knee flexors maximum effective angle. And finally, we have compared the knee flexors maximum effective angle with the moment of maximum force to determine whether these two values are related. Results: The maximum effective angle is decreased regardless of the duration of rehabilitation (p= 0.0019, p = 0.037). It does not change significantly during rehabilitation (p = 0.29). It does not depend on the strength gained during rehabilitation but on a neuromotor change due to the morphological changes caused by surgery. Conclusion: The study results show that anterior cruciate ligament reconstruction with hamstring graft causes a decrease in knee flexor maximum effective angle.
引用
收藏
页码:150 / 155
页数:6
相关论文
共 50 条
  • [41] Graft Differences and Knee Biomechanics six Months After Anterior Cruciate Ligament Reconstruction
    Nawasreh, Zakariya H.
    Logerstedt, David
    White, Kathleen
    Snyder-Mackler, Lynn
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 222 - 223
  • [42] VARIATION IN GASTROCNEMIUS AND HAMSTRINGS MUSCLE ACTIVITY DURING PEAK KNEE FLEXOR FORCE AFTER ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION WITH HAMSTRING GRAFT: A PRELIMINARY CONTROLLED STUDY
    Sequier, Luna
    Forelli, Florian
    Traulle, Maude
    Vandebrouck, Amaury
    Duffiet, Pascal
    Ratte, Louis
    Mazeas, Jean
    INTERNATIONAL JOURNAL OF PHYSIOTHERAPY, 2020, 7 (06) : 282 - 287
  • [43] Effect of Tibiofemoral Rotation Angle on Graft Failure After Anterior Cruciate Ligament Reconstruction
    Leite, Chilan Bou Ghosson
    Merkely, Gergo
    Farina, Evan M.
    Smith, Richard
    Gortz, Simon
    Hazzard, Sean
    Asnis, Peter
    Lattermann, Christian
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2023, 51 (09): : 2291 - 2299
  • [44] Effect of knee angle on quadriceps strength and activation after anterior cruciate ligament reconstruction
    Krishnan, Chandramouli
    Theuerkauf, Paul
    JOURNAL OF APPLIED PHYSIOLOGY, 2015, 119 (03) : 223 - 231
  • [45] Strength and Regrowth of Hamstring Tendons After Hamstring Autograft Anterior Cruciate Ligament Reconstruction
    Battaglia, Todd C.
    Miller, Mark D.
    TECHNIQUES IN ORTHOPAEDICS, 2005, 20 (03) : 334 - 339
  • [46] Hybrid Graft Anterior Cruciate Ligament Reconstruction: A Predictable Graft for Knee Stabilization
    Alvarez-Pinzon, Andres M.
    Barksdale, Leticia
    Krill, Michael K.
    Leo, Brian M.
    ORTHOPEDICS, 2015, 38 (06) : E473 - E476
  • [47] Remodelling of human hamstring autografts after anterior cruciate ligament reconstruction
    Janssen, Rob P. A.
    van der Wijk, Jasper
    Fiedler, Anja
    Schmidt, Tanja
    Sala, Harm A. G. M.
    Scheffler, Sven U.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (08) : 1299 - 1306
  • [48] Knee Flexor Strength and Endurance Profiles After Ipsilateral Hamstring Tendons Anterior Cruciate Ligament Reconstruction
    Vairo, Giampietro L.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2014, 95 (03): : 552 - 561
  • [49] Knee function after anterior cruciate ligament reconstruction with patellar or hamstring tendon: a meta-analysis
    Shi Dong-liang
    Yao Zhen-jun
    CHINESE MEDICAL JOURNAL, 2011, 124 (23) : 4056 - 4062
  • [50] Remodelling of human hamstring autografts after anterior cruciate ligament reconstruction
    Rob P. A. Janssen
    Jasper van der Wijk
    Anja Fiedler
    Tanja Schmidt
    Harm A. G. M. Sala
    Sven U. Scheffler
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 1299 - 1306