Real-Time mmWave Channel Sounding Through Switched Beamforming With 3-D Dual-Polarized Phased-Array Antennas

被引:0
|
作者
Caudill, Derek [1 ]
Chuang, Jack [2 ]
Jun, Sung Yun [1 ]
Gentile, Camillo [2 ]
Golmie, Nada [2 ]
机构
[1] Natl Inst Stand & Technol, RF Technol Div, Boulder, CO 80305 USA
[2] NIST, Wireless Networks Div, Gaithersburg, MD 20899 USA
关键词
Calibration; channel sounder; 5G; millimeter wave (mmWave); propagation; 285; GHz; IMPLEMENTATION;
D O I
10.1109/TMTT.2021.3104278
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We propose a 28.5-GHz channel sounder that switches through all antennas of multiple dual-polarized 8 X 8 phased arrays at the transmitter and receiver and performs beamforming in postprocessing through digital weights to synthesize a sweepable beam. To our knowledge, we are the first to implement-what we refer to as-switched beamforming with phased arrays for millimeter-wave channel sounding, realized through highly stable Rubidium clocks and local oscillators coupled with precision over-the-air calibration techniques developed in house. By circumventing the time-consuming programming of analog weights that is associated with analog beamforming-what phased arrays are designed for-we can sweep a 3-D double-omnidirectional dual-polarized channel in just 1.3 ms, for real-time sounding. By in turn circumventing the coarse precision of analog weights, we can synthesize ideal beam patterns thanks to the effectively infinite precision of digital weights, enabling fine weight calibration for the nonidealities of the system hardware and fine weight tapering for sidelobe suppression. This translates to average estimation errors of 0.47 degrees in 3-D double-directional angle, 0.48 dB in co-polarized path gain, and 0.18 ns in delay, as substantiated by field measurements.
引用
收藏
页码:5021 / 5032
页数:12
相关论文
共 50 条
  • [41] Si-Based 94-GHz Phased Array Transmit and Receive Modules for Real-Time 3D Radar Imaging
    Plouchart, Jean-Olivier
    Gu, Xiaoxiong
    Lee, Wooram
    Tzadok, Asaf
    Liu, Duixian
    Liu, Huijian
    Yeck, Mark
    Baks, Christian
    Valdes-Garcia, Alberto
    2019 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2019, : 532 - 535
  • [42] SIMULTANEOUS BILATERAL REAL-TIME 3-D TRANSCRANIAL ULTRASOUND IMAGING AT 1 MHZ THROUGH POOR ACOUSTIC WINDOWS
    Lindsey, Brooks D.
    Nicoletto, Heather A.
    Bennett, Ellen R.
    Laskowitz, Daniel T.
    Smith, Stephen W.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (04): : 721 - 734
  • [43] Peer-Reviewed Technical Communication A Low-Complexity Real-Time 3-D Sonar Imaging System With a Cross Array
    Liu, Xuesong
    Zhou, Fan
    Zhou, Hong
    Tian, Xiang
    Jiang, Rongxin
    Chen, Yaowu
    IEEE JOURNAL OF OCEANIC ENGINEERING, 2016, 41 (02) : 262 - 273
  • [44] QUANTIFICATION OF SHUNT VOLUME THROUGH VENTRICULAR SEPTAL DEFECT BY REAL-TIME 3-D COLOR DOPPLER ECHOCARDIOGRAPHY: AN IN VITRO STUDY
    Zhu, Meihua
    Ashraf, Muhammad
    Tam, Lydia
    Streiff, Cole
    Kimura, Sumito
    Shimada, Eriko
    Sahn, David J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (05): : 1193 - 1200
  • [45] 4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography
    Wildes, Douglas
    Lee, Warren
    Haider, Bruno
    Cogan, Scott
    Sundaresan, Krishnakumar
    Mills, David M.
    Yetter, Christopher
    Hart, Patrick H.
    Haun, Christopher R.
    Concepcion, Mikael
    Kirkhorn, Johan
    Bitoun, Marc
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (12) : 2159 - 2173
  • [46] Image-free real-time 3-D tracking of a fast-moving object using dual-pixel detection
    Deng, Qiwen
    Zhang, Zibang
    Zhong, Jingang
    OPTICS LETTERS, 2020, 45 (17) : 4734 - 4737
  • [47] Broadband Beamforming of Focal Plane Array (FPA) Signals Using Real-Time Spatio-Temporal 3D FIR Frustum Digital Filters
    Gunaratne, Thushara K.
    Bruton, Len
    Agathoklis, Pan
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2011, 59 (06) : 2029 - 2040
  • [48] 3-D Real-Time Volumetric Imaging Using 20 MHz 1.5-mm Diameter Single-Chip CMUT-on-CMOS Array
    Tekes, Coskun
    Gurun, Gokce
    Rashid, Muhammad W.
    Zahorian, Jaime
    Xu, Toby
    Hasler, Jennifer
    Degertekin, F. Levent
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012,
  • [49] Real-time 3-D image reconstruction of a 24x24 row-column addressing array-from raw data to image
    Li, Chunyu
    Yang, Jiali
    Li, Xu
    Zhong, Xiaoli
    Song, Junjie
    Ding, Mingyue
    Ming Yuchi
    MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790
  • [50] Real-time 125-Gb/s DP-QPSK signal delivery over 150 m based on a dual-polarized single-channel W-band wireless link enabled by photonics
    Cai, Yuancheng
    Zhu, Min
    Zhang, Jiao
    Lei, Mingzheng
    Hua, Bingchang
    Zou, Yucong
    Luo, Wei
    Xiang, Shitong
    Tian, Liang
    Ding, Junjie
    Ma, Like
    Huang, Yongming
    Yu, Jianjun
    You, Xiaohu
    2023 OPTICAL FIBER COMMUNICATIONS CONFERENCE AND EXHIBITION, OFC, 2023,