Crystalloid Coload Reduced the Incidence of Hypotension in Spinal Anesthesia for Cesarean Delivery, When Compared to Crystalloid Preload: A Meta-Analysis

被引:18
|
作者
Ni, Hai-Fang [1 ]
Liu, Hua-yue [1 ]
Zhang, Juan [1 ]
Peng, Ke [1 ]
Ji, Fu-Hai [1 ]
机构
[1] Soochow Univ, Affiliated Hosp 1, Dept Anesthesiol, 188 Shizi St, Suzhou 215006, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
MATERNAL HYPOTENSION; RINGERS SOLUTION; PREVENTION; INDUCTION; SECTION; PEPTIDE; VOLUME; TRIAL;
D O I
10.1155/2017/3462529
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective. To determine whether crystalloid infusion just after intrathecal injection (coload) would be better than infusion before anesthesia (preload) for hypotension prophylaxis in spinal anesthesia for cesarean delivery. Methods. We searched PubMed, EMBASE, Cochrane Central Register of Controlled Trials, and other databases for randomized controlled trials comparing coload of crystalloid with preload in parturients receiving spinal anesthesia for cesarean delivery. Primary outcome was intraoperative incidence of hypotension. Other outcomes were intraoperative need for vasopressors, hemodynamic variables, neonatal outcomes (umbilical artery pH and Apgar scores), and the incidence of maternal nausea and vomiting. We used RevMan 5.2 and STATA 12.0 for the data analyses. Results. Ten studies with 824 cases were included. The incidence of hypotension was significantly higher in the preload group compared with the coload group (57.8% versus 47.1%, odds ratio [OR] = 1.62, 95% confidence interval [CI] = 1.11-2.37, and P = 0.01). More patients needed intraoperative vasopressors (OR = 1.71, 95% CI = 1.07-2.04, and P = 0.02) when receiving crystalloid preload. In addition, the incidence of nausea and vomiting was higher in the preload group (OR = 3.40, 95% CI = 1.88-6.16, and P < 0.0001). There were no differences in neonatal outcomes between the groups. Conclusions. For parturients receiving crystalloid loading in spinal anesthesia for cesarean delivery, coload strategy is superior to preload for the prevention of maternal hypotension.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Colloid Preload Versus Coload for Spinal Anesthesia for Cesarean Delivery: The Effects on Maternal Cardiac Output
    Teoh, Wendy H. L.
    Sia, Alex T. H.
    ANESTHESIA AND ANALGESIA, 2009, 108 (05): : 1592 - 1598
  • [22] Prevention of hypotension during spinal anesthesia for cesarean delivery - An effective technique using combination phenylephrine infusion and crystalloid cohydration
    Kee, WDN
    Khaw, KS
    Ng, FF
    ANESTHESIOLOGY, 2005, 103 (04) : 744 - 750
  • [23] The Effects of Crystalloid and Colloid Preload on Cardiac Output in the Parturient Undergoing Planned Cesarean Delivery Under Spinal Anesthesia: A Randomized Trial
    Tamilselvan, Perumal
    Fernando, Roshan
    Bray, Johanna
    Sodhi, Manisha
    Columb, Malachy
    ANESTHESIA AND ANALGESIA, 2009, 109 (06): : 1916 - 1921
  • [24] Effects of crystalloid and colloid preload on blood volume in the parturient undergoing spinal anesthesia for elective cesarean section
    Ueyama, H
    He, YL
    Tanigami, H
    Mashimo, T
    Yoshiya, I
    ANESTHESIOLOGY, 1999, 91 (06) : 1571 - 1576
  • [25] Failure to prevent hypotension after spinal anesthesia for elective cesarean section despite crystalloid or colloid preload augmentation is probably mediated by atrial natriuretic peptide
    Lang, J
    Jayasinghe, C
    Woodson, L
    Ahmad, M
    Mathru, M
    ANESTHESIOLOGY, 1996, 85 (3A) : A904 - A904
  • [26] Comparison of intravenous colloid and colloid-crystalloid combination in hypotension prophylaxis during spinal anesthesia for cesarean section
    Idehen, H. O.
    Amadasun, F. E.
    Ekwere, I. T.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2014, 17 (03) : 309 - 313
  • [27] Colloid vs. crystalloid preloading to prevent maternal hypotension during spinal anesthesia for elective cesarean section
    Dahlgren, G
    Granath, F
    Pregner, K
    Rösblad, PG
    Wessel, H
    Irestedt, L
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (08) : 1200 - 1206
  • [28] The Crystalloid Co-Load: Clinically as Effective as Colloid Preload for Preventing Hypotension from Spinal Anaesthesia for Caesarean Delivery
    Riley, Edward T.
    Mangum, Kevin
    Carvalho, Brendan
    Butwick, Alexander J.
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2019, 47 (01) : 35 - 40
  • [29] Up-and-Down Determination of Different Crystalloid Coload Volumes on the ED 90 of Prophylactic Norepinephrine Infusion for Preventing Postspinal Anesthesia Hypotension During Cesarean Section
    Chen, Yi
    Xiong, Xiangsheng
    Qin, Rui
    Guo, Lei
    Shi, Yongqiang
    Ni, Xinli
    DRUG DESIGN DEVELOPMENT AND THERAPY, 2024, 18 : 2609 - 2616
  • [30] Comparison between colloid preload and crystalloid co-load in cesarean section under spinal anesthesia: a randomized controlled trial
    Tawfik, M. M.
    Hayes, S. M.
    Jacoub, F. Y.
    Badran, B. A.
    Gohar, F. M.
    Shabana, A. M.
    Abdelkhalek, M.
    Emara, M. M.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2014, 23 (04) : 317 - 323