Study on Interface Interaction between Uniaxial Geogrid Reinforcement and Soil Based on Tensile and Pull-Out Tests

被引:6
|
作者
Cai, Xiaoguang [1 ,2 ,3 ]
Feng, Jiayu [1 ]
Li, Sihan [1 ,2 ,3 ]
Xu, Honglu [4 ]
Liu, Weiwei [5 ]
Huang, Xin [1 ,2 ,3 ,4 ]
机构
[1] Inst Disaster Prevent, Coll Geol Engn, Sanhe 065201, Peoples R China
[2] Hebei Key Lab Earthquake Disaster Prevent & Risk, Sanhe 065201, Peoples R China
[3] CEA Key Lab Bldg Collapse Mech & Disaster Prevent, Sanhe 065201, Peoples R China
[4] China Earthquake Adm, Inst Engn Mech, Harbin 150080, Peoples R China
[5] Aolai Guoxin Beijing Testing Technol Co Ltd, Beijing 101318, Peoples R China
关键词
uniaxial geogrid; tensile test; pull-out test; tensile properties; friction coefficient; LABORATORY MODEL; RETAINING WALL; BEHAVIOR; STRAIN; PERFORMANCE; SCALE;
D O I
10.3390/su141610386
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The interaction between reinforcement and soil is a key problem in the application of geosynthetics as reinforcement in geotechnical engineering. In this study, tensile and pull-out tests on a uniaxial geogrid were carried out using self-designed tensile and pull-out test equipment. The tensile test evaluated the tensile load-strain characteristics of a geogrid. Under the condition of lateral confinement, the tensile force and secant tensile stiffness of the geogrid increased with an increase in the normal stress when the strain was constant, and the secant tensile stiffness decreased with a decrease in the tensile rate. The stiffness coefficient was used to quantitatively describe the change in the stiffness of the reinforcement. Using the pull-out test, the variation laws of the pull-out force of the geogrid under different normal stresses and different longitudinal rib percentages were obtained. When the geogrid was broken, the pull-out force of the same type of geogrid was not significantly different under different normal stresses. With an increase in the longitudinal rib percentage, the pull-out force of the geogrid under the same normal stress gradually increased, and the apparent friction coefficient was obtained by analysis. The results of the apparent friction coefficient obtained by the analytical method in accordance with French specifications (NF P94-270-2020) are relatively safe compared to the experimental values.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] SOIL-GEOGRID REINFORCEMENT INTERACTION BY PULLOUT AND DIRECT SHEAR TESTS
    ALFARO, MC
    MIURA, N
    BERGADO, DT
    GEOTECHNICAL TESTING JOURNAL, 1995, 18 (02): : 157 - 167
  • [42] Soil-geotextile pull-out interaction properties: testing and interpretation
    Juran, Ilan
    Chen, Chao L.
    Transportation Research Record, 1988, (1188) : 37 - 47
  • [43] Pull-out test on interface behavior between expansive soils and geogrids
    Cai Jian-tao
    ROCK AND SOIL MECHANICS, 2015, 36 : 204 - 208
  • [44] Bond strength of galvanized steel: experimental and numerical study based on pull-out tests
    Luna Molina, Francisco Javier
    Fernandez Ruiz, Manuel Alejandro
    Hernandez Montes, Enrique
    Alonso Alonso, Maria Cruz
    3RD INTERNATIONAL CONFERENCE ON MECHANICAL MODELS IN STRUCTURAL ENGINEERING (CMMOST 2015), 2015, : 143 - 158
  • [45] Discrete Element Analysis of the Load Transfer Mechanism of Geogrid-Ballast Interface under Pull-Out Load
    Li, Jing
    Jia, Ya-Fei
    Miao, Chen-Xi
    Xie, Ming-Xing
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [46] Bond-Slip Behavior Between GFRP Bars and Mortar Based on Pull-Out Tests
    Jin, Qingping
    Wang, Guangbo
    Liang, Tingying
    Chen, Peixia
    POLYMER COMPOSITES, 2019, 40 (07) : 2840 - 2849
  • [47] Numerical investigations of the interface behaviour between granular soil and a geogrid reinforcement
    Bauer, Erich
    Tantono, Sendy F.
    INTERNATIONAL JOURNAL OF COMPUTER APPLICATIONS IN TECHNOLOGY, 2009, 34 (01) : 23 - 32
  • [48] Full-range analysis of elastic-plastic model of pull-out interface between geosynthetics and soil
    Du C.
    Yi F.
    Meitan Xuebao/Journal of the China Coal Society, 2020, 45 (12): : 4062 - 4073
  • [49] Interface between steel rebar and concrete, studied by electromechanical pull-out testing
    Fu, XL
    Chung, DDL
    COMPOSITE INTERFACES, 1999, 6 (02) : 81 - 92
  • [50] Results of cone and piston pull-out tests for evaluation of clay-soil adhesion
    Cheshomi, Akbar
    Jafari, Mehdi
    Rajabi, Ali M.
    SOIL & TILLAGE RESEARCH, 2023, 225