The Performance of the Beam Conditions and Radiation Monitoring System of CMS

被引:0
|
作者
Dabrowski, A. E. [1 ]
Bacchetta, N. [1 ]
Bell, A. J. [1 ]
Castro, E. [1 ]
Guthoff, M. [1 ]
Hall-Wilton, R. [1 ]
Hempel, M. [1 ]
Henschel, H. [1 ]
Lange, W. [1 ]
Lohmann, W. [1 ]
Mueller, S. [1 ]
Novgorodova, O. [1 ]
Pfeiffer, D. [1 ]
Ryjov, V. [1 ]
Stickland, D. [1 ]
Walsh, R. [1 ]
机构
[1] CERN, CH-1211 Geneva 23, Switzerland
来源
2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2011年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Beam Conditions and Radiation Monitoring System (BRM), is installed in CMS to protect the CMS detector from high beam losses and to provide feedback to the LHC and CMS on the beam conditions. The primary detector subsystems are based on either single crystal diamond sensors (BCM1F) for particle counting with nanosecond resolution or on polycrystalline diamonds (BCM2; BCM1L) for integrated signal current measurements. Beam scintillation counters (BSC) are also used during low luminosity running. The detectors have radiation hard front-end electronics and are read out independently of the CMS central data acquisition and are online whenever there is beam in the LHC machine. The various sub-systems exploit different time resolutions and position locations to be able to monitor the beam induced backgrounds and the flux of particles produced during collisions. This paper describes the CMS BRM system and the complementary aspects of the installed BRM sub-detectors to measure both single particle count rates and signal currents originating from beam backgrounds and collision products in CMS.
引用
收藏
页码:489 / 495
页数:7
相关论文
共 50 条
  • [31] Performance of CMS ECAL Preshower in 2007 test beam
    Li, Syue-Wei
    Go, Apollo
    Kuo, Chia-Ming
    XIII INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2009, 160
  • [32] Fast beam condition monitor for CMS: Performance and upgrade
    Leonard, Jessica L.
    Bell, Alan
    Burtowy, Piotr
    Dabrowski, Anne
    Hempel, Maria
    Henschel, Hans
    Lange, Wolfgang
    Lohmann, Wolfgang
    Odell, Nathaniel
    Penno, Marek
    Pollack, Brian
    Przyborowski, Dominik
    Ryjov, Vladimir
    Stickland, David
    Walsh, Roberval
    Warzycha, Weronika
    Zagozdzinska, Agnieszka
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 765 : 235 - 239
  • [33] Presentation layer of CMS Online Monitoring System
    Andre, Jean-Marc
    Behrens, Ulf
    Branson, James
    Brummer, Philipp
    Cittolin, Sergio
    Gomes, Diego Da Silva
    Darlea, Georgiana-Lavinia
    Deldicque, Christian
    Demiragli, Zeynep
    Dobson, Marc
    Doualot, Nicolas
    Erhan, Samim
    Fulcher, Jonathan Richard
    Gigi, Dominique
    Gladki, Maciej
    Glege, Frank
    Gomez-Ceballos, Guillelmo
    Hegeman, Jeroen
    Holzner, Andre
    Janulis, Mindaugas
    Lettrich, Michael
    Mecionis, Audrius
    Meijers, Frans
    Meschi, Emilio
    Mommsen, Remigius K.
    Morovic, Srecko
    O'Dell, Vivian
    Orsini, Luciano
    Papakrivopoulos, Ioannis
    Paus, Christoph
    Petrova, Petia
    Petrucci, Andrea
    Pieri, Marco
    Rabady, Dinyar
    Racz, Attila
    Rapsevicius, Valdas
    Reis, Thomas
    Sakulin, Hannes
    Schwick, Christoph
    Simelevicius, Dainius
    Stankevicius, Mantas
    Velez, Cristina Vazquez
    Wernet, Christian
    Zejdl, Petr
    23RD INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2018), 2019, 214
  • [34] CMS electromagnetic calorimeter performance and test beam results
    Bruneliere, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01): : 33 - 35
  • [35] Test beam results on the performance of the CMS electromagnetic calorimeter
    Zabi, Alexandre
    Calorimetry in High Energy Physics, 2006, 867 : 350 - 357
  • [36] Radiation monitoring and beam dump system of the OPAL silicon microvertex detector
    Braibant, S
    NUCLEAR PHYSICS B, 1997, : 299 - 304
  • [37] Radiation monitoring and beam dump system of the OPAL silicon microvertex detector
    Biebel, O
    Braibant, S
    de Jong, SJ
    Hammarstrom, R
    Hilgers, R
    Honma, AK
    Jovanovic, P
    Lauber, JA
    Neal, HA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 403 (2-3): : 351 - 362
  • [38] Design of the beam loss monitoring system in strong prompt radiation field
    Li, Juexin
    Li, Yuxiong
    Li, Weimin
    Gong, Guanghua
    Zhao, Zhengguo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 465 - 467
  • [39] The CMS muon system: Physics performance
    S. Lacaprara
    The European Physical Journal C - Particles and Fields, 2004, 34 : s75 - s83
  • [40] PERFORMANCE EVALUATION OF THE CMS MODULEX TREATMENT PLANNING SYSTEM FOR ELECTRON-BEAM DOSE COMPUTATIONS
    PURDY, JA
    HARMS, WB
    GERBER, RL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (09): : 1230 - 1230