Outcomes Following Different Fixation Strategies of Neer Type IIB Distal Clavicle Fractures

被引:7
|
作者
Gutman, Michael J. [1 ]
Joyce, Christopher D. [1 ]
Patel, Manan S. [1 ]
Lazarus, Mark D. [1 ]
Horneff, John G. [1 ]
机构
[1] Thomas Jefferson Univ, Rothman Inst, Philadelphia, PA 19107 USA
来源
关键词
Clavicle fracture; Neer IIB distal clavicle fracture; Acromioclavicular separation; Hook plate; Locking plate; Bosworth screw; Suture repair; LOCKING PLATE; HOOK-PLATE; SCREW FIXATION;
D O I
10.22038/ABJS.2021.54472.2718
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Multiple surgical techniques for fixation of Neer type IIB distal clavicle fractures have been described without consensus on optimal treatment. The purpose of this study is to compare functional and radiographic results with surgical management of Neer type IIB distal clavicle fractures at a single institution. Methods: Sixty-three patients with acute Neer type IIB fractures treated operatively were evaluated. Patients with a minimum of two year follow up were included. Functional scores included American Shoulder and Elbow Surgeons (ASES), Single Assessment Numeric Evaluation (SANE), Simple Shoulder Test (SST), and Likert patient satisfaction (1 to 5). Radiographs were assessed for osseous union and coracoclavicular (CC) distance. Results: Thirty-eight patients met inclusion with a mean follow-up of 5.3 years. Patients were divided into five groups based on fixation technique: suture-only CC fixation (n=6), CC screw fixation only (n=3), open reduction internal fixation (OR IF) without CC fixation (n=8), hook plate fixation (n=4), and ORIF with suture CC reconstruction (n=17). Outcome scores for the entire cohort were 91.8 for ASES, 90.2 for SANE, and 10.8 for STT. Patients with hook plates had significantly lower SANE score (p=0.016), but no other significant differences in functional, satisfaction, or radiographic outcomes were found between groups. Sixteen patients (42.1%) required reoperation. Conclusion: Treatment of Neer type IIB fractures via suture- only fixation, plate-only fixation, or a combination of both demonstrated satisfactory mid to long term outcomes. While implant removal was more common in the CC screw and ORIF groups, no fixation technique proved functionally superior.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 50 条
  • [31] Comparison of the efficacy of a distal clavicular locking plate with and without a suture anchor in the treatment of Neer IIb distal clavicle fractures
    Xu, Hua
    Chen, Wen Jun
    Zhi, Xiao Cheng
    Chen, Shi Chang
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01) : 503
  • [32] Comparison of Locking Plate Fixation and Coracoclavicular Ligament Reconstruction for Neer Type 2B Distal Clavicle Fractures
    Kim, Dong Jin
    Lee, Yoon Min
    Yoon, Eun Ji
    Sur, Yoo Joon
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2022, 10 (03)
  • [33] What is the optimal surgical treatment for Neer type IIB (IIC) distal clavicle fractures? A systematic review and meta-analysis
    Panagopoulos, Andreas
    Solou, Konstantina
    Tatani, Irini
    Triantafyllopoulos, Ioannis K.
    Lakoumentas, John
    Kouzelis, Antonis
    Athanasiou, Vasileios
    Kokkalis, Zinon T.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [34] Different inner fixation strategies for Neer type II and type V lateral clavicular fractures
    Han, Zhihua
    Wu, Jianhong
    Wang, Qiugen
    Wu, Xiaoming
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (01): : 183 - 184
  • [35] Different inner fixation strategies for Neer type II and type V lateral clavicular fractures
    Zhihua Han
    Jianhong Wu
    Qiugen Wang
    Xiaoming Wu
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 183 - 184
  • [36] Coracoclavicular stabilization using a suture button device for Neer type IIB lateral clavicle fractures
    Cho, Chul-Hyun
    Jung, Jae-Hoon
    Kim, Beom-Soo
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (05) : 804 - 808
  • [37] FRACTURES OF THE DISTAL CLAVICLE - A CASE FOR FIXATION
    EDWARDS, DJ
    KAVANAGH, TG
    FLANNERY, MC
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1992, 23 (01): : 44 - 46
  • [38] Surgical treatment of Neer type II fractures of the distal clavicle: a meta-analysis
    Stegeman, S. A.
    Nacak, H.
    Huvenaars, K. H. J.
    Stijnen, T.
    Krijnen, Pieta
    Schipper, Inger B.
    BRITISH JOURNAL OF SURGERY, 2012, 99 : S7 - S7
  • [39] Locking plate combined with titanium cable for Neer type II distal clavicle fractures
    Zhang, Fan
    Fu, Qiang
    Li, Yongchuan
    Lu, Nan
    Chen, Aimin
    Zhao, Liangyu
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [40] Neer type II distal clavicle fractures: hook plate versus transacromial pin
    Mechchat, Atif
    Elidrissi, Mohammed
    Shimi, Mohammed
    Elibrahimi, Abdelhalim
    Elmrini, Abdelmajid
    PAN AFRICAN MEDICAL JOURNAL, 2015, 20