Effect of Tree Channel Conductivity on Electrical Tree Shape and Breakdown in XLPE Cable Insulation Samples

被引:124
|
作者
Chen, Xiangrong [1 ]
Xu, Yang [1 ]
Cao, Xiaolong [1 ]
Dodd, S. J. [2 ]
Dissado, L. A. [2 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[2] Univ Leicester, Dept Engn, Leicester LE1 7RH, Leics, England
基金
美国国家科学基金会;
关键词
XLPE cable insulation; electrical tree shape; fractal; multi-fractal; partial discharge; breakdown; conducting tree; PARTIAL DISCHARGES; PROPAGATION; GROWTH; RANGE; IMAGE;
D O I
10.1109/TDEI.2011.5931074
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The results of an investigation into electrical tree growth in XLPE cable insulation using an embedded needle electrode are reported for a range of voltages from 9 kV rms to 27 kV rms. The partial discharge (PD) activity and tree structures were measured simultaneously throughout the tree growth and the trees were recorded from initiation up to and including the final runaway stage. A multifractal analysis was also performed on the tree structures as they propagated, and it was found that their fractal dimension increased and the distribution of embedded structures changed as small side channels were added to the tree as it grew. At 11 kV rms only branch trees were found and only bush (bush-branch) trees at higher voltages, but at 9 kV rms trees of three different shapes were formed. Observation of the tree shapes at 9 kV rms under reflected light followed by a detailed analysis using con-focal Raman spectroscopy, showed that the stagnated and branch-pine (monkey puzzle) tree shapes were due to the formation of a conducting graphitic deposit upon the walls on tree branches in the region of the needle electrode. This was not present in the branch trees produced at 9 kV rms. A simple scheme is presented for the formation of branch-pine trees and their corresponding PD activity based on the concept of conducting branch generation. The trees produced at 13 kV rms and above have a bush shape, which converts into a bush-branch shape when a runaway branch grows from their periphery. This is shown to happen when the field at the bush tree periphery exceeded a voltage independent critical value, which was estimated to be 100 MV/m. The consequence of this result for the initiation of the runaway stage in branch trees is commented upon.
引用
收藏
页码:847 / 860
页数:14
相关论文
共 50 条
  • [21] The relationship between electrical characteristics and electrical tree degradation in XLPE insulation
    Kang, DS
    Sun, JH
    Lee, HS
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 546 - 549
  • [22] THE EFFECT OF MORPHOLOGY ON THE IMPULSE VOLTAGE BREAKDOWN IN XLPE CABLE INSULATION
    FUKUDA, T
    IRIE, S
    ASADA, Y
    MAEDA, M
    NAKAGAWA, H
    YAMADA, N
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1982, 17 (05): : 386 - 391
  • [23] The Effect of Frequency on the Breakdown of XLPE Cable Insulation with Artificial Defects
    Li, Weiwei
    Li, Jianying
    Zhou, Fusheng
    Wang, Shihang
    Li, Huan
    Li, Shengtao
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 375 - 378
  • [24] Electrical Tree Initiation in XLPE Cable Insulation under Constant DC, Grounded DC, and at Elevated Temperature
    Liu, Ying
    Cao, Xiaolong
    Chen, George
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (06) : 2287 - 2295
  • [25] Electrical Treeing Behavior at High Temperature in XLPE Cable Insulation Samples
    Chen, Xiangrong
    Xu, Yang
    Cao, Xiaolong
    Gubanski, S. M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (05) : 2841 - 2851
  • [26] Breakdown mechanisms of XLPE cable with insulation defects
    Arachchige, Thanuja Gawasingha
    Narampanawa, Lakshitha
    Ekanayake, Chandima
    Ma, Hui
    2020 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (2020 IEEE CEIDP), 2020, : 71 - 74
  • [27] Experimental investigation on the cause of harmfulness of the blue water tree to XLPE cable insulation
    Katsuta, G
    Toya, A
    Li, Y
    Okashita, M
    Aida, F
    Ebinuma, Y
    Ohki, Y
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1999, 6 (06) : 887 - 891
  • [28] Experimental investigation on the cause of harmfulness of the blue water tree to XLPE cable insulation
    Tokyo Electric Power Co., Ltd., Tokyo, Japan
    不详
    不详
    IEEE Trans Dielectr Electr Insul, 6 (887-891):
  • [29] OXIDATION AND WATER TREE FORMATION IN SERVICE-AGED XLPE CABLE INSULATION
    GARTON, A
    BAMJI, S
    BULINSKI, A
    DENSLEY, J
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1987, 22 (04): : 405 - 412
  • [30] The growth of electrical tree and its PD in inner and outer layer of 110kV XLPE cable insulation
    Wang, Wei
    Sui, Heng
    Yu, YanLong
    Wu, Yankun
    Chen, Guanghui
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,