Laminar Natural Convection Heat Transfer From Vertical 7 x 7 Rod Bundles in Liquid Sodium

被引:3
|
作者
Hata, Koichi [1 ]
Fukuda, Katsuya [1 ]
Mizuuchi, Tohru [2 ]
机构
[1] Kobe Univ, Grad Sch Maritime Sci, 5-1-1 Fukae Minami, Kobe, Hyogo 6580022, Japan
[2] Kyoto Univ Gokasho, Inst Adv Energy, Uji, Kyoto 6110011, Japan
关键词
laminar natural convection heat transfer; liquid sodium; vertical 7 x 7 rod bundle; array size; ESA; ETA; FUEL BUNDLE; WIRE;
D O I
10.1115/1.4042356
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Laminar natural convection heat transfer from vertical 7 x 7 rod bundle in liquid sodium was numerically analyzed to optimize the thermal-hydraulic design for the bundle geometry with equilateral square array (ESA). The unsteady laminar three-dimensional basic equations for natural convection heat transfer caused by a step heat flux were numerically solved until the solution reaches a steady-state. The code of the parabolic hyperbolic or elliptic numerical integration code series (PHOENICS) was used for the calculation considering the temperature dependence of thermophysical properties concerned. The 7 x 7 heated rods for diameter (D = 0.0076 m), length (L = 0.2 m) and L/D (= 26.32) were used in this work. The surface heat fluxes for each cylinder, which was uniformly heated along the length, were equally given for a modified Rayleigh number, (Ra-f,Ra-L)(ij) and (Ra-f,Ra-L)(Nx x Ny,S/D), ranging from 3.08 x 10(4) to 4.28 x 10(7) (q = 1 x 10(4) similar to 7 x 10(6) W/m(2)) in liquid temperature (T-L = 673.15 K). The values of ratio of the diagonal center-line distance between rods for bundle geometry to the rod diameter (S/D) for vertical 7 x 7 rod bundle were ranged from 1.8 to 6 on the bundle geometry with ESA. The spatial distribution of average Nusselt numbers for a vertical single cylinder of a rod bundle, (Nu(av))(ij), and average Nusselt numbers for a vertical rod bundle, (Nu(av,B))(Nx x Ny,S/D), were clarified. The average values of Nusselt number, (Nu(av))(ij) and (Nu(av,B))(Nx x Ny,S/D), for the bundle geometry with various values of S/D were calculated to examine the effect of array size, bundle geometry, S/D, (Ra-f,Ra-L)(ij) and (Ra-f,Ra-L)(Nx x Ny,S/D) on heat transfer. The bundle geometry for the higher (Nu(av,B))(Nx x Ny,S/D) value under the condition of S/D = constant was examined. The general correlations for natural convection heat transfer from a vertical N-x x N-y rod bundle with the ESA and equilateral triangle array (ETA), including the effects of array size, (Ra-f,Ra-L)(Nx x Ny,S/D) and S/D were derived. The correlations for vertical N-x x N-y rod bundles can describe the theoretical values of (Nu(av,B))(Nx x Ny,S/D) for each bundle geometry in the wide analytical range of S/D (= 1.8-6) and the modified Rayleigh number ((Ra-f,Ra-L)(Nx x Ny,S/D) = 3.08 x 10(4) to 4.28 x 10(7)) within x 9.49 to 10.6% differences.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] NATURAL CONVECTION HEAT TRANSFER FROM VERTICAL SQUARE DUCTS
    Ali, Mohamed E.
    HT2008: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, VOL 1, 2009, : 293 - 300
  • [42] NATURAL CONVECTION HEAT TRANSFER FROM VERTICAL TRIANGULAR DUCTS
    Ali, Mohamed E.
    Al-Ansary, Hany
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE 2009, VOL 2, 2009, : 421 - 428
  • [43] SIMULTANEOUS HEAT AND MASS TRANSFER IN LAMINAR FREE CONVECTION FROM A VERTICAL PLATE
    DENBOUTER, JA
    DEMUNNIK, B
    HEERTJES, PM
    CHEMICAL ENGINEERING SCIENCE, 1968, 23 (10) : 1185 - +
  • [44] OPTIMUM PLATE SPACINGS FOR LAMINAR NATURAL CONVECTION HEAT TRANSFER FROM PARALLEL VERTICAL ISOTHERMAL FLAT PLATES
    LEVY, EK
    JOURNAL OF HEAT TRANSFER, 1971, 93 (04): : 463 - &
  • [45] LAMINAR NATURAL CONVECTION HEAT TRANSFER IN ELLIS FLUIDS
    TIEN, C
    TSUEI, HS
    APPLIED SCIENTIFIC RESEARCH, 1969, 20 (2-3): : 131 - &
  • [46] Fully developed laminar natural convection heat and mass transfer in partially heated vertical pipe
    Lee, KT
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2000, 27 (07) : 995 - 1001
  • [47] NATURAL-CONVECTION HEAT-TRANSFER FROM A HORIZONTAL CYLINDER TO LIQUID-SODIUM
    SUGIYAMA, K
    MA, Y
    ISHIGURO, R
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1988, 30 (01): : 71 - 76
  • [48] Critical heat flux in tight 7-rod bundles
    Cheng, X
    Erbacher, FJ
    Müller, U
    CONVECTIVE FLOW AND POOL BOILING, 1999, : 345 - 351
  • [49] Experimental study of liquid sodium flow and heat transfer characteristics along a hexagonal 7-rod bundle
    Hou, Yandong
    Wang, Liu
    Wang, Mingjun
    Zhang, Kui
    Zhang, Xisi
    Hu, Wenjun
    Wu, Yingwei
    Tian, Wenxi
    Qiu, Suizheng
    Su, G. H.
    APPLIED THERMAL ENGINEERING, 2019, 149 : 578 - 587
  • [50] LAMINAR NATURAL-CONVECTION HEAT-TRANSFER FROM AN INCLINED CYLINDER
    ALARABI, M
    SALMAN, YK
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1980, 23 (01) : 45 - 51