Experimental Validation of Estimated 4D-MRI for MR-Guided Radiotherapy Based on Orthogonal Cine-MRI with a Porcine Lung Phantom

被引:0
|
作者
Rabe, M. [1 ]
Paganelli, C. [2 ]
Riboldi, M. [3 ]
Bondesson, D. [4 ]
Schneider, M. [4 ]
Chmielewski, T. [5 ]
Dinkel, J. [4 ]
Reiner, M. [1 ]
Landry, G. [1 ,3 ]
Parodi, K. [3 ]
Belka, C. [1 ,6 ]
Kamp, F. [1 ]
Kurz, C. [1 ,3 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiat Oncol, Munich, Germany
[2] Politecn Milan, Dipartimento Elettron Informaz & Bioingegneria, Milan, Italy
[3] Ludwig Maximilians Univ Muenchen LMU Munich, Dept Med Phys, Garching, Germany
[4] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, Munich, Germany
[5] ViewRay Inc, Oakwood Village, OH USA
[6] German Canc Consortium DKTK, Partner Site Munich, Munich, Germany
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
TU-EF-TRAC
引用
收藏
页码:E327 / E327
页数:1
相关论文
共 50 条
  • [41] Correcting geometric image distortions in slice-based 4D-MRI on the MR-linac
    Keesman, Rick
    van de Lindt, Tessa N.
    Juan-Cruz, Celia
    van den Wollenberg, Wouter
    van der Bijl, Erik
    Nowee, Marlies E.
    Sonke, Jan-Jakob
    van der Heide, Uulke A.
    Fast, Martin F.
    MEDICAL PHYSICS, 2019, 46 (07) : 3044 - 3054
  • [42] Feasibility of delivered dose reconstruction for MR-guided SBRT of pancreatic tumors with fast, real-time 3D cine MRI
    Grimbergen, Guus
    Pötgens, Giulia G.
    Eijkelenkamp, Hidde
    Raaymakers, Bas W.
    Intven, Martijn P. W.
    Meijer, Gert J.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182
  • [43] How the sampling strategy of 2D MRI affects imaging latencies in real-time MR-guided radiotherapy
    Borman, P.
    Tijssen, H. N.
    Bos, C.
    Moonen, C. T. W.
    Raaymakers, B. W.
    Glitzner, M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S100 - S100
  • [44] Real-time motion monitoring using orthogonal cine MRI during MR-guided adaptive radiation therapy for abdominal tumors on 1.5T MR-Linac
    Jassar, Hassan
    Tai, An
    Chen, Xinfeng
    Keiper, Timothy D. D.
    Paulson, Eric
    Lathuiliere, Fabienne
    Beriault, Silvain
    Hebert, Francois
    Savard, Laurence
    Cooper, David T. T.
    Cloake, Sneha
    Li, X. Allen
    MEDICAL PHYSICS, 2023, 50 (05) : 3103 - 3116
  • [45] Rapid MRI for Personalized 4D Image-Guided Lung Cancer Radiotherapy
    Sawant, A.
    Yuan, Q.
    Khatri, G.
    Joshi, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [47] Synthetic 4DCT(MRI) lung phantom generation for 4D radiotherapy and image guidance investigations
    Duetschler, Alisha
    Bauman, Grzegorz
    Bieri, Oliver
    Cattin, Philippe C.
    Ehrbar, Stefanie
    Engin-Deniz, Georg
    Giger, Alina
    Josipovic, Mirjana
    Jud, Christoph
    Krieger, Miriam
    Nguyen, Damien
    Persson, Gitte F.
    Salomir, Rares
    Weber, Damien C.
    Lomax, Antony J.
    Zhang, Ye
    MEDICAL PHYSICS, 2022, 49 (05) : 2890 - 2903
  • [48] Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom
    Yue, Y.
    Fan, Z.
    Yang, W.
    Pang, J.
    McKenzie, E.
    Deng, Z.
    Tuli, R.
    Sandler, H.
    Li, D.
    Fraass, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 572 - 573
  • [49] A ROI-based global motion model established on 4DCT and 2D cine-MRI data for MRI-guidance in radiation therapy
    Garau, Noemi
    Via, Riccardo
    Meschin, Giorgia
    Lee, Danny
    Keall, Paul
    Riboldi, Marco
    Baroni, Guido
    Paganelli, Chiara
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (04):
  • [50] Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom
    Yue, Yong
    Fan, Zhaoyang
    Yang, Wensha
    Pang, Jianing
    Deng, Zixin
    McKenzie, Elizabeth
    Tuli, Richard
    Wallace, Robert
    Li, Debiao
    Fraass, Benedick
    MEDICAL PHYSICS, 2015, 42 (10) : 5787 - 5797