Indoor Plants as Air Cleaners

被引:0
|
作者
Dela Cruz, M. [1 ]
Christensen, J. H. [1 ]
Mueller, R. [1 ]
机构
[1] Univ Copenhagen, Fac Sci, Dept Plant & Environm Sci, Copenhagen, Denmark
关键词
volatile organic compounds; toluene; pollutants; removal; purification; Hedera helix; PURIFICATION CAPABILITY; FORMALDEHYDE REMOVAL; MICROCOSM; VOLATILES; BENZENE; SYSTEMS;
D O I
10.17660/ActaHortic.2015.1093.14
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
Plants have been used decoratively indoors for centuries. For the last 25-30 years, their beneficial abilities to reduce the levels of harmful volatile organic compounds (VOCs) from the indoor air have also been investigated. Previous studies have shown that VOCs are removed by the plant itself, but also by microorganisms in the soil. Furthermore, the rate of removal is dependent on the plant species and can be influenced by exogenous factors such as light intensity and VOC concentration. The research within this field is, however, limited by the fact that the knowledge gained from laboratory experiments is not directly transferrable to real life settings. The largest problem is the use of closed chambers where there is no air exchange. This also results in a declining VOC concentration over time. Due to this limitation, we constructed a new experimental system which among others can allow for air exchange and a constant VOC concentration. With the new system it was found that removal rates obtained in chambers with air exchange and constant VOC concentration were significantly higher than removal rates obtained in closed chambers. This means that removal rates obtained in closed chambers may be an underestimation of the plants' real potential. The next step will be to use the new system to investigate the effects of the exogenous factors temperature, light intensity and CO2 concentration on VOC removal rates.
引用
收藏
页码:133 / 137
页数:5
相关论文
共 50 条
  • [31] The Assessment of Indoor Formaldehyde and Bioaerosol Removal by Using Negative Discharge Electrostatic Air Cleaners
    Liu, Chao-Yun
    Tseng, Chao-Heng
    Wang, Kai-Feng
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (12)
  • [32] EVALUATION OF THE EFFECTIVENESS OF SEVERAL AIR CLEANERS FOR REDUCING THE HAZARD FROM INDOOR RADON PROGENY
    HOPKE, PK
    MONTASSIER, N
    WASIOLEK, P
    AEROSOL SCIENCE AND TECHNOLOGY, 1993, 19 (03) : 268 - 278
  • [33] AIR CLEANERS - A REVIEW
    FOX, RW
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1994, 94 (02) : 413 - 416
  • [34] INDOOR ENVIRONMENT AND HEALTH PLANTS FOR CLEAN AIR
    Loegstrup, Jorgen
    Andersen, Soren Thorhauge
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1037 - 1048
  • [35] Plants for Sustainable Improvement of Indoor Air Quality
    Brilli, Federico
    Fares, Silvano
    Ghirardo, Andrea
    de Visser, Pieter
    Calatayud, Vicent
    Munoz, Amalia
    Annesi-Maesano, Isabella
    Sebastiani, Federico
    Alivernini, Alessandro
    Varriale, Vincenzo
    Menghini, Flavio
    TRENDS IN PLANT SCIENCE, 2018, 23 (06) : 507 - 512
  • [36] PLANTS AND THEIR MAGNIFICENT INDOOR AIR PURIFYING ATTRIBUTES
    Ramanlal, Dharitri B.
    Kumar, Rita N.
    Kumar, Nirmal J., I
    EVERYMANS SCIENCE, 2018, 53 (05): : 311 - 315
  • [37] INVESTIGATIONS FOR IMPROVING OPERATION OF AIR CLEANERS OF LAND GAS-TURBINE PLANTS
    ALEKSEEV, AV
    MIKHAILOV, EI
    SOKOLOV, NV
    THERMAL ENGINEERING, 1972, 19 (07) : 36 - 39
  • [38] Field measurement of the impact of natural ventilation and portable air cleaners on indoor air quality in three occupant states
    Yin H.
    Li Z.
    Zhai X.
    Ning Y.
    Gao L.
    Cui H.
    Ma Z.
    Li A.
    Energy and Built Environment, 2023, 4 (05): : 601 - 613
  • [40] Evaluation of ozone generation and indoor organic compounds removal by air cleaners based on chamber tests
    Yu, Kuo-Pin
    Lee, Grace Whei-May
    Hsieh, Ching-Pei
    Lin, Chi-Chi
    ATMOSPHERIC ENVIRONMENT, 2011, 45 (01) : 35 - 42