Dosimetric evaluation for temporomandibular joint cone beam computed tomography exams using different field of view

被引:0
|
作者
Pinto, Carla Alves [1 ]
Caetano, Gabriela Franco da Rosa [1 ]
Andrade, Marcos Ely Almeida [2 ]
Panzarella, Francine Kull [1 ]
Junqueira, Jose Luiz Cintra [1 ]
Peroni, Leonardo Vieira [3 ]
Nascimento, Monikelly do Carmo Chagas [1 ]
机构
[1] Inst Pesquisas Sao Leopoldo Mand, Fac Sao Leopoldo Mand, Div Oral Radiol, BR-13045755 Campinas, SP, Brazil
[2] Univ Tiradentes, Dept Radiol, BR-13045755 Recife, PE, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Div Oral Radiol, Dept Oral Diag, BR-13045755 Piracicaba, SP, Brazil
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2021年 / 7卷 / 06期
关键词
temporomandibular joint; thermoluminescent dosimetry; cone beam computed tomography; radiation dosage; radiation exposure; IMAGE QUALITY; CT; SIZE;
D O I
10.1088/2057-1976/ac240a
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives. To optimize the absorbed organ dose in relation to the field of view for temporomandibular joint examinations in four cone beam computed tomography devices. Methods. An anthropomorphic adult head and neck phantom, and 192 LiF dosimeters (TLD-100) were used. The dosimeters were placed in the region corresponding to the lens, parotid glands, submandibular glands, and thyroid. Small, medium and large FOVs were selected on Orthopantomograph OP300 Maxio, PaX-i3D Smart, ORTHOPHOS XG, and i-CAT Next Generation device when it was possible. Results. A wide range of absorbed dose values was recorded for all organs due to the different exposure parameters of each device. The radiosensitive organ with the highest dose was the parotid glands. The devices with 5 x 5 cm FOV recorded a lower dose in this protocol, while for the device without a small FOV (<= 5 x 5 cm), the lowest dose was observed with the large FOV (6 x 16 cm). Conclusions. We recommend a double exposure with an FOV of 5 x 5 cm in the OP300 Maxio, PaX-i3D Smart, and ORTHOPHOS XG device, while in the i-CAT Next Generation device, a single exposure FOV of 6 x 16 cm is indicated.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Cone-beam computed tomography to detect erosions of the temporomandibular joint: Effect of field of view and voxel size on diagnostic efficacy and effective dose
    Librizzi, Zachary T.
    Tadinada, Aditya S.
    Valiyaparambil, Jayasanker V.
    Lurie, Alan G.
    Mallya, Sanjay M.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (01) : E25 - E30
  • [22] Comparative cone-beam computed tomography evaluation of the osseous morphology of the temporomandibular joint in temporomandibular dysfunction patients and asymptomatic individuals
    Yasa, Yasin
    Akgul, Hayati Murat
    ORAL RADIOLOGY, 2018, 34 (01) : 31 - 39
  • [23] Comparative cone-beam computed tomography evaluation of the osseous morphology of the temporomandibular joint in temporomandibular dysfunction patients and asymptomatic individuals
    Yasin Yasa
    Hayati Murat Akgül
    Oral Radiology, 2018, 34 : 31 - 39
  • [24] Temporomandibular joint morphology in Korean using cone-beam computed tomography: influence of age and gender
    Yun, Ji-Min
    Choi, Young-Jun
    Woo, Su-Heon
    Lee, Ui-Lyong
    MAXILLOFACIAL PLASTIC AND RECONSTRUCTIVE SURGERY, 2021, 43 (01)
  • [25] Temporomandibular joint morphology in Korean using cone-beam computed tomography: influence of age and gender
    Ji-Min Yun
    Young-Jun Choi
    Su-Heon Woo
    Ui-Lyong Lee
    Maxillofacial Plastic and Reconstructive Surgery, 43
  • [26] Age-stratified analysis of temporomandibular joint osteoarthritis using cone-beam computed tomography
    Song, Hee-Jeong
    Choi, Hang-Moon
    Shin, Bo-Mi
    Kim, Young-Jun
    Park, Moon-Soo
    Kim, Cheul
    IMAGING SCIENCE IN DENTISTRY, 2024, 54 (01) : 71 - 80
  • [27] Classification of temporomandibular joint osteoarthritis on cone beam computed tomography images using artificial intelligence system
    Eser, Gozde
    Duman, Suayip Burak
    Bayrakdar, Ibrahim Sevki
    Celik, Ozer
    JOURNAL OF ORAL REHABILITATION, 2023, 50 (09) : 758 - 766
  • [28] Temporomandibular joint osteoarthritis: cone beam computed tomography findings, clinical features, and correlations
    Kilic, S. Comert
    Kilic, N.
    Sumbullu, M. A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (10) : 1268 - 1274
  • [29] Small field of view cone beam CT temporomandibular joint imaging dosimetry
    Lukat, T. D.
    Wong, J. C. M.
    Lam, E. W. N.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (10)
  • [30] Evaluation of a low-dose protocol for cone beam computed tomography of the temporomandibular joint - ethical and methodological considerations
    Reis, Larissa de Oliveira
    Lopes Rosado, Lucas P.
    Gaeta-Araujo, Hugo
    Freitas, Deborah Queiroz
    DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (01)