Intrasession repeatability and intersession reproducibility of peripapillary OCTA vessel parameters in non-glaucomatous and glaucomatous eyes

被引:23
|
作者
Lee, Jae Chang [1 ]
Grisafe, Dominic J. [1 ]
Burkemper, Bruce [1 ]
Chang, Brenda R. [1 ]
Zhou, Xiao [2 ]
Chu, Zhongdi [2 ]
Fard, Ali [3 ]
Durbin, Mary [3 ]
Wong, Brandon J. [1 ]
Song, Brian J. [1 ]
Xu, Benjamin Y. [1 ]
Wang, Ruikang [2 ]
Richter, Grace M. [1 ]
机构
[1] Univ Southern Calif, Keck Sch Med, Ophthalmol, 1450 San Pablo St,Suite 4700, Los Angeles, CA 90033 USA
[2] Univ Washington, Bioengn, Seattle, WA 98195 USA
[3] Carl Zeiss Meditec Inc, Dublin, CA USA
基金
美国国家卫生研究院;
关键词
Glaucoma; Imaging; Optic Nerve; COHERENCE TOMOGRAPHY ANGIOGRAPHY; OPEN-ANGLE GLAUCOMA; MACULAR PERFUSION; CAPILLARY DENSITY; OPTIC-NERVE; DETERMINANTS; RETINA;
D O I
10.1136/bjophthalmol-2020-317181
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective To compare intrasession repeatability versus intersession reproducibility of the peripapillary vessel parameters using optical microangiography-based optical coherence tomography angiography (OCTA) in non-glaucomatous and glaucomatous eyes. Methods In an observational, longitudinal study, peripapillary OCTA scans were collected to evaluate intrasession repeatability and intersession reproducibility using within-eye coefficient of variation (CVW) and intraclass correlation coefficient (ICC). Images were quantified using a custom research-oriented quantification software calculating vessel area density (VAD) and flux and a commercially developed, clinic-oriented quantification software (Cirrus 11.0, Carl Zeiss Meditec) calculating perfusion density (PD) and flux index (FI). Effect of signal strength on the reliability of OCTA parameters was also evaluated. Results Among 120 non-glaucomatous eyes, intrasession CVW were 4.2% for VAD, 5.3% for flux, 1.5% for PD and 2.0% for FI. The intersession CVW were 6.5% for VAD, 8.0% for flux, 2.0% for PD and 3.2% for FI. The intrasession ICC ranged from 0.928 to 0.945, and intersession ICC ranged from 0.811 to 0.866. From 118 glaucomatous eyes, intrasession CVW was 9.0% for VAD, 10.3% for flux, 1.7% for PD and 2.3% for FI. The intersession CVW was 12.1% for VAD, 14.2% for flux, 2.3% for PD and 3.5% for FI. The intrasession ICC ranged from 0.904 to 0.972, and intersession ICC ranged from 0.855 to 0.955. Signal strength was significantly positively associated with OCTA vessel parameters (p<0.0001) for both groups. Conclusion Peripapillary OCTA vessel parameters had greater intrasession repeatability compared to intersession reproducibility in both non-glaucomatous and glaucomatous eyes. The built-in commercially developed quantification software demonstrated greater agreement than the custom research-oriented quantification software.
引用
收藏
页码:1534 / 1541
页数:8
相关论文
共 50 条
  • [31] Thickness of the Lamina Cribrosa, and the Anatomic Relationships Between the Lamina Cribrosa and the Cerebrospinal Fluid and Intraocular Spaces in Glaucomatous and Non-Glaucomatous Eyes
    Lerner, F.
    Croxatto, I. O.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [32] Comparison of learning neural networks and linear discriminant functions to discriminate between glaucomatous and non-glaucomatous eyes using HRT optic disc topography parameters.
    Bowd, C
    Chan, K
    Zangwill, LM
    Lee, TW
    Sejnowski, TJ
    Goldbaum, MH
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S118 - S118
  • [33] Effect of bilateral sequential cataract extraction on intraocular pressure in non-glaucomatous Asian eyes
    Ngo, Wei Kiong
    Tan, Colin S. H.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (04) : 560 - 564
  • [34] Changes in symmetry of anterior chamber following routine cataract surgery in non-glaucomatous eyes
    Hanbin Lee
    Ieva Zukaite
    Valerie Juniat
    Maria E. Dimitry
    Amanda Lewis
    Mayank A. Nanavaty
    Eye and Vision, 6
  • [35] Intersession reproducibility of retinal nerve fiber layer thickness measurements by GDx-VCC in healthy and glaucomatous eyes
    Iacono, Pierluigi
    Da Pozzo, Stefano
    Fuser, Mirko
    Marchesan, Roberta
    Ravalico, Giuseppe
    OPHTHALMOLOGICA, 2006, 220 (04) : 266 - 271
  • [36] Disc haemorrhage associated with an enlarged peripapillary intrachoroidal cavitation in a non-glaucomatous myopic eye: a case report
    Kyoung Min Lee
    Eun Ji Lee
    Seung Hyen Lee
    Tae-Woo Kim
    BMC Ophthalmology, 15
  • [37] In Vivo Relationship of Corneal and Scleral Stiffness with Bruch's Membrane Opening Minimum Rim Width in Glaucomatous versus Non-Glaucomatous Eyes
    Madhan, Nayasha S.
    Buma, Stephen
    Ma, Yanhui
    Mahmoud, Ashraf
    Fleming, Gloria
    Roberts, Cynthia J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [38] Morphologic, Electrophysiologic, and Visual Function Parameters in Children with Non-Glaucomatous Cupping of Prematurity
    Pawlak, Marta
    Gotz-Wieckowska, Anna
    Sowinska, Anna
    SEMINARS IN OPHTHALMOLOGY, 2015, 30 (5-6) : 410 - 416
  • [39] Reproducibility of Peripapillary Retinal Nerve Fiber Thickness Measurement With Spectral Domain OCT(Spectralis) in Glaucomatous Eyes
    Kim, M.
    An, G.
    Park, K.
    Kim, D.
    Kim, T. -W.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [40] Anterior Chamber Biometric Parameters Associated With Intraocular Pressure Reduction After Phacoemulsification in Non-Glaucomatous Eyes With Open Angles
    Sarkar, Deepayan
    Anshukita, Anshukita
    Karkhur, Samendra
    Sharma, Bhavana
    Gupta, Saroj
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)