Design of Piston-Driven Automated Cardiopulmonary Resuscitation Device with Patient Monitoring System

被引:0
|
作者
Alam, Md. Mujtabir [1 ]
Amin, Md. Ashik [1 ]
Hussain, Mahamud [1 ]
Bhuiyan, Rokibul Hasan [2 ]
Khan, Mohammad Monirujjaman [1 ]
机构
[1] North South Univ, Dept Elect & Comp Engn, Dhaka, Bangladesh
[2] Concordia Univ, Dept Elect & Comp Engn, Montreal, PQ, Canada
关键词
manual CPR; automated CPR; chest compressions; piston-driven; heart rate; respiratory rate;
D O I
10.1109/icrest.2019.8644482
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cardiopulmonary Resuscitation (CPR) is an emergency medical procedure applied when a patient's heart stops functioning suddenly, mainly due to cardiac arrest, drowning or electric shock. Normally, CPR is applied manually but the process is ineffective to provide adequate chest compressions to cardiac arrest patients. The main objective in this paper is to design a mechanized process of providing CPR and thus replacing the traditional manual CPR technique altogether. We designed an automated CPR device with piston-driven chest compression system and a patient monitoring system. The patient monitoring system consists of a heart rate monitor, body temperature monitor and respiratory rate monitor. The heart rate monitor is integrated with the automated CPR device. This means that when the heart rate monitor detects patient's heart beat then the automated CPR device will not operate but if the heart rate monitor detects no heart beat then the automated CPR device will immediately provide CPR to the patient. The automated CPR along with the patient monitoring system has been tested on a CPR manikin and the results of the performance is well within the accepted CPR guidelines.
引用
收藏
页码:211 / 216
页数:6
相关论文
共 50 条
  • [41] Monitoring System of Regional Cerebral Oxygen Saturation During Pre-hospital Cardiopulmonary Resuscitation
    Tajima, Goro
    Shiozaki, Tadahiko
    Izumino, Hiroo
    Yamano, Shuhei
    Inokuma, Takamitsu
    Hirao, Tomohito
    Yamashita, Kazunori
    Nagatani, Atsuko
    Tasaki, Osamu
    CIRCULATION, 2013, 128 (22)
  • [42] Design and Implementation of An Automated Load Scheduling and Monitoring System
    Liyanage, B. L. C. B.
    Tharushika, G. H. A. S.
    Liyanage, K. L. S., V
    Porambage, M. D.
    Abeygunawardane, S. K.
    Wijesiriwardana, R.
    2019 MORATUWA ENGINEERING RESEARCH CONFERENCE (MERCON) / 5TH INTERNATIONAL MULTIDISCIPLINARY ENGINEERING RESEARCH CONFERENCE, 2019, : 216 - 221
  • [43] Ambient oxygen concentrations resulting from use of the Lund University Cardiopulmonary Assist System (LUCAS) device during simulated cardiopulmonary resuscitation
    Deakin, Charles D.
    Paul, Vinu
    Fall, Emma
    Petley, Graham W.
    Thompson, Fizz
    RESUSCITATION, 2007, 74 (02) : 303 - 309
  • [44] Rationale and Design of a Wearable Cardiopulmonary Monitoring System for Improving the Efficiency of Critical Care Monitoring
    Lee, Jina
    Hwang, You-Mi
    Park, Sung-Min
    APPLIED SCIENCES-BASEL, 2023, 13 (24):
  • [45] Cardiopulmonary Resuscitation in the Hospitalized Patient: Impact of System-Based Variables on Outcomes in Cardiac Arrest
    Kantamineni, Phani
    Emani, Vamsi
    Saini, Ankur
    Rai, Hardeep
    Duggal, Abhijit
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2014, 348 (05): : 377 - 381
  • [46] Design of a Supraharmonic Monitoring System Based on an FPGA Device
    Barkas, Dimitris A.
    Ioannidis, George Ch.
    Kaminaris, Stavros D.
    Psomopoulos, Constantinos S.
    SENSORS, 2022, 22 (05)
  • [47] Design of Calibration System for Vehicle Speed Monitoring Device
    Gao, Junli
    Song, Haitao
    Fang, Qiang
    Cai, Xiaoqing
    INFORMATION AND MANAGEMENT ENGINEERING, PT VI, 2011, 236 : 166 - +
  • [48] Application of an automated cardiopulmonary resuscitation device for kidney transplantation from uncontrolled donation after cardiac death donors in the emergency department
    Morozumi, Junya
    Matsuno, Naoto
    Sakurai, Etsuo
    Nakamura, Yuki
    Arai, Takao
    Ohta, Shoichi
    CLINICAL TRANSPLANTATION, 2010, 24 (05) : 620 - 625
  • [49] Effect of an automated ventilator and the impedance threshold device on coronary perfusion pressure and cerebral blood flow during cardiopulmonary resuscitation in pigs
    Zhong, Jing-Quan
    Hu, Xudong
    Hare, Gregory M.
    Mazer, C. D.
    So, Petsy P.
    Debicki, Donna
    Dorian, Paul
    CIRCULATION, 2006, 114 (18) : 553 - 553
  • [50] AN AUTOMATED TEST ENVIRONMENT FOR A MEDICAL PATIENT MONITORING-SYSTEM
    GORING, D
    HEWLETT-PACKARD JOURNAL, 1991, 42 (04): : 49 - 52