Evaluation of the Tibiofemoral Contact Characteristics of a Customized Surface-Guided Knee Implant

被引:3
|
作者
Pejhan, Shabnam [1 ,4 ]
Khosravipour, Ida [1 ]
Gascoyne, Trevor [2 ]
Bohm, Eric [2 ,3 ]
Brandt, Jan-Mels [1 ]
Luo, Yunhua [1 ]
Wyss, Urs [1 ,2 ]
机构
[1] Univ Manitoba, Dept Mech Engn, Winnipeg, MB R3T 5V6, Canada
[2] Orthopaed Innovat Ctr, Winnipeg, MB R2L 4L5, Canada
[3] Univ Manitoba, Dept Surg, Sect Orthoped Surg, Winnipeg, MB R3A 1R9, Canada
[4] Univ Manitoba, Dept Mech Engn, Engn & Informat Technol Complex, Winnipeg, MB, Canada
关键词
Total knee replacement; Pressure-sensitive film; Finite element; Surface-guided; HIGH-FLEXION; REPLACEMENT; STRESSES; JOINT; DAMAGE; AREAS; GAIT; FILM;
D O I
10.1007/s40846-018-0399-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A surface-guided total knee replacement (TKR) aims to achieve close to normal kinematics through specially shaped tibiofemoral articulating surfaces. The resulting geometry of the TKR components affects the tibiofemoral contact mechanics. Therefore, evaluation of the contact characteristics of the implant is critical, as the tibiofemoral contact stress influences the short-term and long-term performance and durability of the implants. In this study, the contact behavior at the tibiofemoral articulating interface for a customized surface-guided TKR was studied. The contact area and mean contact stress at specific flexion angles were measured mechanically by pressure sensitive films to validate the outcomes from finite element analysis (FEA) under similar load conditions. Two activities of daily living were studied; lunging and squatting. As expected, FEA predicted larger contact areas at various flexion angles due to the limited sensitivity range of the pressure sensitive films. During lunging and squatting, the contact area increased as the flexion angle reached 90 degrees, and decreased as the knee was flexed to higher angles. The mean contact pressure was less than 10MPa at 120 degrees of flexion under squatting load. The outcomes revealed that a high range of motion can be achieved, while the mean contact pressure remains below the material limits of the tibial polyethylene insert.
引用
收藏
页码:205 / 212
页数:8
相关论文
共 49 条
  • [21] Technical note: Clinical evaluation of a newly released surface-guided radiation therapy system on DIBH for left breast radiation therapy
    Zhao, Hui
    Sarkar, Vikren
    Paxton, Adam
    Huang, Y. Jessica
    Haacke, Christine
    Price, Ryan G.
    Su, Fan-Chi Frances
    Szegedi, Martin
    Rassiah, Prema
    Salter, Bill
    MEDICAL PHYSICS, 2023, 50 (10) : 5978 - 5986
  • [22] Evaluation of Different Holographic Visualization Techniques for Surface-Guided Patient Alignment Using Mixed Reality (MixR) and the Microsoft Hololens 2
    Jackson, A.
    Johnson, P.
    Feldman, E.
    Martin-gomez, A.
    MEDICAL PHYSICS, 2022, 49 (06) : E400 - E400
  • [23] Evaluation of Daily Patient Position Accuracy and Calculation of Setup Errors with Skin Markers and Surface-Guided Radiotherapy (SGRT) in Breast Cancer
    Bakicierler, G.
    Celik, O. Karakoyun
    Sindir, B.
    Can, O. Duran
    Akgungor, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E641 - E641
  • [24] Evaluation of the detection accuracy of set-up for various treatment sites using surface-guided radiotherapy system, VOXELAN: a phantom study
    Saito, Masahide
    Ueda, Koji
    Suzuki, Hidekazu
    Komiyama, Takafumi
    Marino, Kan
    Aoki, Shinichi
    Sano, Naoki
    Onishi, Hiroshi
    JOURNAL OF RADIATION RESEARCH, 2022, 63 (03) : 435 - 442
  • [25] A biaxial line-contact wear machine for the evaluation of implant bearing materials for total knee joint replacement
    Wang, A
    Essner, A
    Stark, C
    Dumbleton, JH
    WEAR, 1999, 225 : 701 - 707
  • [26] A novel approach to wavefront-guided contact lenses: Aberrations approaching manufacturing tolerances using a surface-customized fitting algorithm
    Schill, Alexander W.
    Maddah, Nasim
    Elam, Evan S.
    Marsack, Jason D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [27] Development of a Surface-Functionalized Titanium Implant for Promoting Osseointegration: Surface Characteristics, Hemocompatibility, and In Vivo Evaluation
    Hou, Ping-Jen
    Syam, Syamsiah
    Lan, Wen-Chien
    Ou, Keng-Liang
    Huang, Bai-Hung
    Chan, Ka-Chun
    Tsai, Chi-Hsun
    Saito, Takashi
    Liu, Chung-Ming
    Chou, Hsin-Hua
    Huang, Yueh-Tzu
    Fa, Fang-Yu
    APPLIED SCIENCES-BASEL, 2020, 10 (23): : 1 - 10
  • [28] The use of a hydrogel implant in the repair of osteochondral defects of the knee: A biomechanical evaluation of restoration of native contact pressures in cadaver knees
    Sismondo, Ronald A.
    Werner, Frederick W.
    Ordway, Nathaniel R.
    Osaheni, Allen O.
    Blum, Michelle M.
    Scuderi, Matthew G.
    CLINICAL BIOMECHANICS, 2019, 67 : 15 - 19
  • [29] Evaluation of initial patient setup methods for breast cancer between surface-guided radiation therapy and laser alignment based on skin marking in the Halcyon system
    Seonghee Kang
    Hyeongmin Jin
    Ji Hyun Chang
    Bum‑Sup Jang
    Kyung Hwan Shin
    Chang Heon Choi
    Jung-in Kim
    Radiation Oncology, 18
  • [30] Evaluation of initial patient setup methods for breast cancer between surface-guided radiation therapy and laser alignment based on skin marking in the Halcyon system
    Kang, Seonghee
    Jin, Hyeongmin
    Chang, Ji Hyun
    Jang, Bum-Sup
    Shin, Kyung Hwan
    Choi, Chang Heon
    Kim, Jung-in
    RADIATION ONCOLOGY, 2023, 18 (01)