Designing a multi-reflection time-of-flight mass analyzer for LPT

被引:13
|
作者
Tian, Y. L. [1 ,2 ]
Wang, Y. S. [1 ]
Wang, J. Y. [1 ]
Zhou, X. H. [1 ]
Huang, W. X. [1 ]
机构
[1] Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Time-of-flight mass spectrometer; Multiple-reflection; Mass measurement; Isobar separation; Exotic nuclei; PENNING TRAP; SPECTROMETRY; SEPARATOR; FACILITY;
D O I
10.1016/j.ijms.2016.08.013
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A new method including two sub-procedures, global search and local refine, has been developed and presented to design a multiple-reflection time-of-flight (MRTOF) mass analyzer. By using this method, a different type of MRTOF mass analyzer, in which each mirror consists of five cylindrical electrodes, has been designed for isobaric separation for Lanzhou Penning Trap (LPT). The optimal potential parameters of the electrodes have been obtained and the maximal resolving power has been achieved to be 1.3 x 10(5) with a total time-of-flight of 6.5 ms for an ion species of Ar-40(1+). The simulation shows that the inaccuracy of the potentials applied to the mirror electrodes must be less than 50 ppm or preferably 20 ppm. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 50 条
  • [41] Multi-reflection time-of-flight mass spectrometer with ion funnel front end for ultimate sensitivity and resolving power
    Shvartsburg, Alexandre A.
    Tang, Keqi
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [42] First off-line tests and performance of the Notre Dame multi-reflection time-of-flight mass spectrometer
    Kelly, J. M.
    Brodeur, M.
    Liu, B.
    Campagna, Q.
    Gonzales, C.
    Maier, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 463 : 485 - 487
  • [43] Improving wide-band mass measurements in a multi-reflection time-of-flight mass spectrograph by usage of a concomitant measurement scheme
    Schury, P.
    Ito, Y.
    Rosenbusch, M.
    Miyatake, H.
    Wada, M.
    Wollnik, H.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2018, 433 : 40 - 46
  • [44] A multi-reflection time-of-flight setup for the study of atomic clusters produced by magnetron sputtering
    Giesel, Paul F.
    Fischer, Paul
    Schweikhard, Lutz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (02):
  • [45] Multi-reflection time-of-flight mass spectrometry with combined in-trap lift capture and mirror-switch ejection
    Knauer, S.
    Fischer, P.
    Marx, G.
    Schabinger, B.
    Schweikhard, L.
    Wolf, R. N.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 423 : 46 - 53
  • [46] High-stability, high-voltage power supplies for use with multi-reflection time-of-flight mass spectrographs
    Schury, P.
    Wada, M.
    Wollnik, H.
    Moon, J-Y
    Hashimoto, T.
    Rosenbusch, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (01):
  • [47] A multi-reflection time-of-flight setup for the improvement and development of new methods and the study of atomic clusters
    Knauer, S.
    Fischer, P.
    Marx, G.
    Mueller, M.
    Rosenbusch, M.
    Schabinger, B.
    Schweikhard, L.
    Wolf, R. N.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2019, 446
  • [48] Decay-correlated mass measurement technique via multi-reflection time-of-flight mass spectrograph with the a//3-TOF detector
    Niwase, T.
    Wada, M.
    Schury, P.
    Rosenbusch, M.
    Kaji, D.
    Morimoto, K.
    Kimura, S.
    Xian, W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2023, 541 : 197 - 199
  • [49] On-line separation of short-lived nuclei by a multi-reflection time-of-flight device
    Wolf, R. N.
    Beck, D.
    Blaum, K.
    Boehm, Ch.
    Borgmann, Ch.
    Breitenfeldt, M.
    Herfurth, F.
    Herlert, A.
    Kowalska, M.
    Kreim, S.
    Lunney, D.
    Naimi, S.
    Neidherr, D.
    Rosenbusch, M.
    Schweikhard, L.
    Stanja, J.
    Wienholtz, F.
    Zuber, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 686 : 82 - 90
  • [50] Mass-selective ion ejection from multi-reflection time-of-flight devices via a pulsed in-trap lift
    Wienholtz, F.
    Kreim, S.
    Rosenbusch, M.
    Schweikhard, L.
    Wolf, R. N.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 421 : 285 - 293