Ultra-fast hierarchical backprojection for Micro-CT reconstruction

被引:5
|
作者
Brokish, Jeffrey [1 ]
Bresler, Yoram [2 ]
机构
[1] InstaRecon Inc, Champaign, IL USA
[2] Univ Illinois, Dept Elect & Comp Engn, Coordinated Sci Lab, Urbana, IL USA
关键词
D O I
10.1109/NSSMIC.2007.4437101
中图分类号
O59 [应用物理学];
学科分类号
摘要
This paper introduces a new version of a fast and accurate O(N(3)logN) reconstruction algorithm for cone-beam CT with a circular source trajectory. This is the first report on the performance of this algorithm with high-resolution large-matrix Micro-CT data. We determined that a software implementation of the FHBP algorithm on off-the-shelf workstations can provide speedups by an order of magnitude or more in Micro-CT reconstruction with no perceptible loss of image quality as compared to state-of-the-art commercial software implementations of conventional reconstruction. This is especially important for Micro-CT reconstructions, where maximum image size can be as large as 8Kx8K pixels per slice and reconstruction of such image volumes can span days. Owing to its algorithmic acceleration, the FHBP-based code achieves the performance of a cluster of computers on a single PC, and could provide even faster reconstruction rates if running on the entire cluster.
引用
收藏
页码:4460 / +
页数:3
相关论文
共 50 条
  • [31] Sparse-view Image Reconstruction in Prospectively Gated Micro-CT for Fast and Low-dose Imaging
    Min, Jonghwan
    Cho, Gyuseong
    Cho, Seungryong
    Kim, Kyoungwoo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (07) : 1157 - 1160
  • [32] Mojette tomographic reconstruction for micro-CT: a bone and vessels quality evaluation
    Sarkissian, H. Der
    Recur, B.
    Guedon, Jp.
    Blerya, P.
    Pilet, P.
    Amouriq, Y.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [33] Micro-CT for nondestructive 3D reconstruction of MEMS and sensors
    Sasov, A
    MEMS DESIGN, FABRICATION, CHARACTERIZATION, AND PACKAGING, 2001, 4407 : 388 - 394
  • [34] In-line phase contrast micro-CT reconstruction for biomedical specimens
    Fu, Jian
    Tan, Renbo
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 431 - 437
  • [35] Ultra-fast micro machining of cylindrical parts with multiple ultra short pulsed laser sources
    Bruening, Stephan
    Du, Keming
    Gillner, Arnold
    LASER ASSISTED NET SHAPE ENGINEERING 9 INTERNATIONAL CONFERENCE ON PHOTONIC TECHNOLOGIES PROCEEDINGS OF THE LANE 2016, 2016, 83 : 167 - 181
  • [36] Improved Dynamic Micro-CT Imaging Binning for Optimized Image Reconstruction
    Ismail, M. K.
    Xin, Y.
    Hamedani, H.
    Amzajerdian, F.
    Baron, R.
    Loza, L.
    Ruppert, K.
    Kadlecek, S.
    Rizi, R. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [37] Micro-CT Guided 3D Reconstruction of Histological Images
    Nagara, Kai
    Roth, Holger R.
    Nakamura, Shota
    Oda, Hirohisa
    Moriya, Takayasu
    Oda, Masahiro
    Mori, Kensaku
    PATCH-BASED TECHNIQUES IN MEDICAL IMAGING (PATCH-MI 2017), 2017, 10530 : 93 - 101
  • [38] Ultra-fast imaging reveals
    Juel, Anne
    JOURNAL OF FLUID MECHANICS, 2024, 1000
  • [39] Distributed image reconstruction of micro-CT data: Computation and communication issues
    Benson, TM
    Gregor, J
    CIC '05: Proceedings of the 2005 International Conference on Communications in Computing, 2005, : 153 - 159
  • [40] Ultra-fast monocycle generator
    Rothman, JL
    ELECTRONIC DESIGN, 1996, 44 (16) : 102 - 102