Reproducible Quantification of Regional Sympathetic Denervation with [11C]meta-Hydroxyephedrine PET Imaging

被引:4
|
作者
Wang, Jean Z. [1 ,2 ]
Moody, Jonathan B. [3 ]
Kaps, Nicole [1 ]
Britt, Deron [1 ,2 ]
Lavallee, Aaryn [1 ]
Renaud, Jennifer M. [1 ,3 ]
Zelt, Jason G. E. [1 ,2 ,4 ]
Wu, Kai Yi [1 ,2 ]
Beanlands, Rob S. [1 ,2 ,4 ]
Fallavollita, James A. [5 ,6 ]
Canty, John M. [5 ,6 ]
deKemp, Robert A. [1 ]
机构
[1] Univ Ottawa Heart Inst, Dept Med Cardiol, 40 Ruskin St, Ottawa, ON K1Y 4W7, Canada
[2] Univ Ottawa, Fac Med, Ottawa, ON, Canada
[3] INVIA Med Imaging Solut, Ann Arbor, MI USA
[4] Univ Ottawa, Fac Med, Dept Cellular & Mol Med, Ottawa, ON, Canada
[5] Univ Buffalo, Div Cardiovasc Med, Buffalo, NY USA
[6] VA Western New York Healthcare Syst, Buffalo, NY USA
基金
加拿大健康研究院;
关键词
PET; cardiac innervation; innervation tracers; POSITRON-EMISSION-TOMOGRAPHY; HEART-FAILURE; MYOCARDIAL-INFARCTION; VIABLE MYOCARDIUM; C-11-META-HYDROXYEPHEDRINE; EVENTS; INNERVATION; PREDICTION; RISK;
D O I
10.1007/s12350-020-02114-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Regional cardiac sympathetic denervation is predictive of sudden cardiac arrest in patients with ischemic cardiomyopathy. The reproducibility of denervation scores between automated software programs has not been evaluated. This study seeks to (1) compare the inter-rater reliability of regional denervation measurements using two analysis programs: FlowQuant(R) and Corridor4DM(R); (2) evaluate test-retest repeatability of regional denervation scores. Methods N = 190 dynamic [C-11]meta-hydroxyephedrine (HED) PET scans were reviewed from the PAREPET trial in ischemic cardiomyopathy patients with reduced left ventricular ejection fraction(LVEF <= 35%). N = 12 scans were excluded due to non-diagnostic quality. N = 178 scans were analyzed using FlowQuant and Corridor4DM software, each by two observers. Test-retest scans from N = 20 patients with stable heart failure were utilized for test-retest analysis. Denervation scores were defined as extent x severity of relative uptake defects in LV regions with < 75% of maximal uptake. Results were evaluated using intraclass correlation coefficient (ICC) and Bland-Altman coefficient of repeatability (RPC). Results Inter-observer, inter-software, and test-retest ICC values were excellent (ICC = 94% to 99%) and measurement variability was small (RPC < 11%). Mean differences between observers ranged .2% to 1.1% for Corridor4DM (P = .28), FlowQuant (P < .001), and between software programs (P < .001). Kaplan-Meier analysis demonstrated HED scores from both programs were predictive of SCA. Conclusion Inter-rater reliability for both analysis programs was excellent and test-retest repeatability was consistent. The minimal difference in scores between FlowQuant and Corridor4DM supports their use in future trials.
引用
收藏
页码:2745 / 2757
页数:13
相关论文
共 50 条
  • [21] 11c-Hydroxyephedrine PET of hibernating myocardium demonstrates extensive sympathetic denervation
    Luisi, AJ
    Fallavollita, JA
    Toorongian, SA
    Haka, MS
    Suzuki, G
    Canty, JM
    CIRCULATION, 2002, 106 (19) : 387 - 387
  • [22] Does quantification of [11C]meta-hydroxyephedrine and [13N]ammonia kinetics improve risk stratification in ischemic cardiomyopathy
    Jean Z. Wang
    Jason G. E. Zelt
    Nicole Kaps
    Aaryn Lavallee
    Jennifer M. Renaud
    Benjamin Rotstein
    Rob S. B. Beanlands
    James A. Fallavollita
    John M. Canty
    Robert A. deKemp
    Journal of Nuclear Cardiology, 2022, 29 : 413 - 425
  • [23] 11C-Meta-Hydroxyephedrine A Promising PET Radiopharmaceutical for Imaging the Sympathetic Nervous System
    Boschi, Stefano
    Lodi, Filippo
    Boschi, Laura
    Nanni, Cristina
    Chondrogiannis, Sotirios
    Colletti, Patrick M.
    Rubello, Domenico
    Fanti, Stefano
    CLINICAL NUCLEAR MEDICINE, 2015, 40 (02) : E96 - E103
  • [24] Reproducible quantification of cardiac sympathetic innervation using graphical modeling of carbon-11-meta-hydroxyephedrine kinetics with dynamic PET-CT imaging
    Tong Wang
    Kai Yi Wu
    Robert C. Miner
    Jennifer M. Renaud
    Rob S. B. Beanlands
    Robert A. deKemp
    EJNMMI Research, 8
  • [25] Pheochromocytomas:: Detection with 11C hydroxyephedrine PET
    Trampal, C
    Engler, H
    Juhlin, C
    Bergström, M
    Långström, B
    RADIOLOGY, 2004, 230 (02) : 423 - 428
  • [26] Correction to: Does quantification of [11C]meta-hydroxyephedrine and [13N]ammonia kinetics improve risk stratification in ischemic cardiomyopathy
    Jean Z. Wang
    Jason G. E. Zelt
    Nicole Kaps
    Aaryn Lavallee
    Jennifer M. Renaud
    Benjamin Rotstein
    Rob S. B. Beanlands
    James A. Fallavollita
    John M. Canty
    Robert A. deKemp
    Journal of Nuclear Cardiology, 2021, 28 : 2419 - 2420
  • [27] Quantification of myocardial [11C]hydroxyephedrine kinetics in humans
    Harms, H. J.
    De Haan, S.
    Knaapen, P.
    Schuit, R. C.
    Windhorst, A. D.
    Lammertsma, A. A.
    Allaart, C.
    Lubberink, M.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A87 - A88
  • [28] Measurement of metabolites of [C-11] META-hydroxyephedrine, [C-11]MHED.
    Link, JM
    Krohn, KA
    Caldwell, JH
    Synovec, RE
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 934 - 934
  • [29] [11C]meta-Hydroxyephedrine - Determination of Labelled Metabolites in Rat Plasma and Heart, and in Serial Plasma Samples from Human Subjects During PET Studies
    Osman, S.
    Law, M. P.
    Pike, V. W.
    Turton, D. R.
    Journal of Labelled Compounds and Radiopharmaceuticals,
  • [30] [11C]meta-Hydroxyephedrine - Determination of Labelled Metabolites in Rat Plasma and Heart, and in Serial Plasma Samples from Human Subjects During PET Studies
    Osman, S.
    Law, M. P.
    Pike, V. W.
    Turton, D. R.
    Journal of Labelled Compounds and Radiopharmaceuticals, 1996,