Stable isotope dilution assay for liquid chromatography-tandem mass spectrometric determination of L-homoarginine in human plasma

被引:61
|
作者
Atzler, Dorothee [1 ]
Mieth, Maren [2 ]
Maas, Renke [2 ]
Boeger, Rainer H. [1 ]
Schwedhelm, Edzard [1 ,3 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Clin Pharmacol & Toxicol, D-20246 Hamburg, Germany
[2] Univ Erlangen Nurnberg, Inst Expt & Clin Pharmacol & Toxicol, Erlangen, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Cardiovasc Res Ctr, Hamburg, Germany
关键词
L-Homoarginine; Nitric oxide; LC-tandem MS; Stable-isotope dilution; ASYMMETRIC DIMETHYLARGININE ADMA; NITRIC-OXIDE SYNTHASE; L-ARGININE; BIOLOGICAL-FLUIDS; DISEASE; QUANTIFICATION; SERUM;
D O I
10.1016/j.jchromb.2011.06.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nitric oxide (NO), the endogenous modulator of vascular tone and structure, originates from oxidation of L-arginine catalysed by NO synthase (NOS). The L-arginine derivative L-homoarginine serves as an alternative NOS substrate releasing NO, competing with L-arginine for NOS, arginase, and arginine transport. In the present article we report a liquid chromatography-tandem mass spectrometric (LC-tandem MS) method for the determination of L-homoarginine in human plasma by stable-isotope dilution. L[(13)C(6)]-Homoarginine was used as internal standard. This method provides high sample throughput of 25-mu l aliquots of plasma with an analysis time of 4 min using LC-tandem MS electrospray ionisation in the positive mode (ESI+). Specific transitions for L-homoarginine and L-[(13)C(6)]-homoarginine were m/z 245 -> m/z 211 and m/z 251 -> m/z 217, respectively. The mean intra- and interassay CVs were 7.4 +/- 4.5% (+/- SD) for 0.1-50 mu mol/L and 7.5 +/- 2.0% for 2 and 5 mu mol/L, respectively. Applying this method, a mean plasma concentration of L-homoarginine of 2.5 +/- 1.0 mu mol/L was determined in 136 healthy humans. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2294 / 2298
页数:5
相关论文
共 50 条
  • [31] Liquid chromatography-tandem mass spectrometric assay for the nucleoside reverse transcriptase inhibitor emtricitabine in human plasma
    Sparidans, Rolf W.
    Prins, Jan M.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (06) : 621 - 627
  • [32] Validation of a liquid chromatography-tandem mass spectrometric assay for the quantitative determination of hydrastine and berberine in human serum
    Gupta, Prem K.
    Hubbard, Martha
    Gurley, Bill
    Hendrickson, Howard R.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (04) : 1021 - 1026
  • [33] Liquid Chromatography-Tandem Mass Spectrometric Assay for AZD9291 in Rat Plasma
    Su, Xin-juan
    Hu, Jie
    Zhang, Lei
    Li, Li
    LATIN AMERICAN JOURNAL OF PHARMACY, 2019, 38 (04): : 737 - 742
  • [34] Liquid chromatography-tandem mass spectrometric assay for the ALK inhibitor crizotinib in mouse plasma
    Sparidans, Rolf W.
    Tang, Seng Chuan
    Nguyen, Luan N.
    Schinkel, Alfred H.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 905 : 150 - 154
  • [35] Liquid Chromatography Tandem Mass Spectrometric Assay for the Determination of Forskolin in Rat Plasma
    Guo Ji-Fen
    Lu Bing
    Meng Fan-Hua
    Zhao Yi-Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (03) : 399 - 402
  • [36] A rapid and sensitive liquid chromatography-tandem mass spectrometric assay for cycloserine in 50 μL of human plasma: Its pharmacokinetic application
    Polagani, Srinivasa Rao
    Pilli, Nageswara Rao
    Maddela, Rambabu
    Gajula, Ramakrishna
    Gandu, Venkateswarlu
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 76 : 21 - 27
  • [37] Quantitative determination of rifampicin in aquatic products by stable isotope-dilution high liquid chromatography-tandem mass spectrometry
    Li, Qin
    Cao, Jingyuan
    Han, Gang
    Liu, Huan
    Yan, Jie
    Wu, Lidong
    Li, Jincheng
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (05)
  • [38] Simultaneous determination of raltegravir and raltegravir glucuronide in human plasma by liquid chromatography-tandem mass spectrometric method
    Wang, Ling-Zhi
    Lee, Lawrence Soon-U
    Thuya, Win-Lwin
    Soon, Gaik Hong
    Kong, Li-Ren
    Nye, Pei-Ling
    Lee, Edmund Jon Deoon
    Flexner, Charles
    Goh, Boon-Cher
    JOURNAL OF MASS SPECTROMETRY, 2011, 46 (02): : 202 - 208
  • [39] High performance liquid chromatography-tandem mass spectrometric determination of rupatadine in human plasma and its pharmacokinetics
    Tian, Yuan
    Zhang, Jingjing
    Lin, Hui
    Liang, Jiabi
    Zhang, Zunjian
    Chen, Yun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (4-5) : 899 - 906
  • [40] Rapid quantitation of digoxin in human plasma and urine using isotope dilution liquid chromatography-tandem mass spectrometry
    Salvador, A
    Sagan, C
    Denouel, J
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (13) : 1917 - 1932